Switchboards are designed with busbars for fuses or circuit breakers that are used for protecting and supplying feeders and branch circuits. Panelboards are designed with a permanently installed main circuit breaker or single set of fuses for disconnecting the number of circuit breakers or fuseholders installed to protect and supply feeders or branch circuits.

SUPPORT AND ARRANGEMENT OF BUSBARS AND CONDUCTORS
408.3

Busbars shall be held firmly in place in the enclosure and shall be arranged in such a way to allow adequate space for conductors to be terminated. Busbars shall be sized with enough capacity to handle the normal currents in amps of the electrical system. In addition, they shall carry safely any type of short-circuit or ground-fault condition.

CONDUCTORS AND BUSBARS ON A SWITCHBOARD OR PANELBOARD
408.3(A)

Conductors and busbars on a switchboard, panelboard, or control board shall be so located as to be free from physical damage. Service sections of such boards shall be separated from the other electrical components. These components shall be properly secured in an approved manner. 

Note, conductors entering a certain section shall terminate in such section, except where it is not practical for control, interconnecting conductors, or other conditions of use.

OVERHEATING AND INDUCTIVE HEATING
408.3(B)

The arrangement of busbars and conductors shall be such as to avoid overheating due to inductive effects. The inductive effect of each conductor is neutralized when grouping all conductors together. To accomplish the minimizing of heating effects, the ungrounded (phase) conductors, grounded (neutral) conductors, and equipment grounding conductors, where used, shall be in the same enclosure, raceway, cable, cord, etc. (See Figure 7-1)

Unfold ↓

You Might Like

Recommended Posts

Will PB compile the source code under PUBLIC when compiling?
When PB compiles NK, will it compile the contents under PUBLIC? If not, where do the built-in DLLs and other things come from? Thank you
碧海沉天 Embedded System
Global demand for sensors and safety system components is high
Market research company Strategy Analytics published a report titled "Automotive Semiconductor Supplier Market Share in 2006", pointing out that in 2006, the revenue of automotive electronic chip supp
Industrial Control Electronics
Some thoughts on FPGA design
Since I started to learn EDA last year, I still feel that I am still outside the door of FPGA. I am very interested in EDA, and the learning process is not easy. After a period of study, I found that
zgjxncytl FPGA/CPLD
The January 2010 issue of Radio contains a new article by Wei Kun
RT, if you are interested, you can buy it and have a look, hehe
springvirus DIY/Open Source Hardware
EEWORLD University Hall----Design of DC power supply system for battery testing equipment
Battery test equipment DC power system design : https://training.eeworld.com.cn/course/5293This video highlights the TI Wide Vin DC/DC Controller and devices from Precision Analog devices as a solutio
hi5 Talking
It is often found that a diode is added between the op amp power supply and the output.
As shown in the figure, what are the two diodes used for? Welcome to discuss this circuit extensively
gaoyang9992006 ADI Reference Circuit

Recommended Content

Circuit

可能感兴趣器件

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

About Us Customer Service Contact Information Datasheet Sitemap LatestNews


Room 1530, 15th Floor, Building B, No.18 Zhongguancun Street, Haidian District, Beijing, Postal Code: 100190 China Telephone: 008610 8235 0740

Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京B2-20211791 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号