• You can log in to your eeworld account to continue watching:
  • GROUNDING OF PANELBOARDS - 408.40
  • Login
  • Duration:2 minutes and 44 seconds
  • Date:2022/09/28
  • Uploader:Lemontree
Introduction
keywords: electronic system
Switchboards are designed with busbars for fuses or circuit breakers that are used for protecting and supplying feeders and branch circuits. Panelboards are designed with a permanently installed main circuit breaker or single set of fuses for disconnecting the number of circuit breakers or fuseholders installed to protect and supply feeders or branch circuits.

SUPPORT AND ARRANGEMENT OF BUSBARS AND CONDUCTORS
408.3

Busbars shall be held firmly in place in the enclosure and shall be arranged in such a way to allow adequate space for conductors to be terminated. Busbars shall be sized with enough capacity to handle the normal currents in amps of the electrical system. In addition, they shall carry safely any type of short-circuit or ground-fault condition.

CONDUCTORS AND BUSBARS ON A SWITCHBOARD OR PANELBOARD
408.3(A)

Conductors and busbars on a switchboard, panelboard, or control board shall be so located as to be free from physical damage. Service sections of such boards shall be separated from the other electrical components. These components shall be properly secured in an approved manner. 

Note, conductors entering a certain section shall terminate in such section, except where it is not practical for control, interconnecting conductors, or other conditions of use.

OVERHEATING AND INDUCTIVE HEATING
408.3(B)

The arrangement of busbars and conductors shall be such as to avoid overheating due to inductive effects. The inductive effect of each conductor is neutralized when grouping all conductors together. To accomplish the minimizing of heating effects, the ungrounded (phase) conductors, grounded (neutral) conductors, and equipment grounding conductors, where used, shall be in the same enclosure, raceway, cable, cord, etc. (See Figure 7-1)

Unfold ↓

You Might Like

Recommended Posts

New generation of ESD protection devices no longer require VCC connection
Due to their ever-decreasing process nodes, digital and analog ICs are increasingly susceptible to damage from electrostatic discharge (ESD), so discrete ESD protection diodes are a necessary componen
qwqwqw2088 Analogue and Mixed Signal
The latest MicroPython official PDF technical documentation (updated to v1.21)
[i=s]This post was last edited by dcexpert on 2023-10-11 11:41[/i]Recently, the official technical documentation has been updated a lot, and many contents have been updated to the latest version. For
dcexpert MicroPython Open Source section
Has anyone used NRF24L01?
Is there any friend who has used RL78 to make 2.4G wireless NRF24L01, SPI communication, I have been adjusting it for a few days but it doesn’t work. Please help. You can also write for me for a fee.
龚瑞 Renesas Electronics MCUs
Question: How to implement X to the Nth power in hardware?
Question: How to implement X to the Nth power in hardware?
TonnySun Embedded System
I want to buy an msp430 development board. Is there any in the forum?
I want to buy an msp430 development board. Is there one in the forum? Thanks. Please post the website address! I also suggest that the moderator open a small section about buying development boards. H
zhy3928551 Microcontroller MCU
Let's dig out the shit together
I suggest that everyone should work together to clean up the shit: Thanks to everyone's love, this forum has many new posts every day. But there are some problems: some very good posts are drowned in
heningbo PCB Design

Recommended Content

Circuit

可能感兴趣器件

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

About Us Customer Service Contact Information Datasheet Sitemap LatestNews