Switchboards are designed with busbars for fuses or circuit breakers that are used for protecting and supplying feeders and branch circuits. Panelboards are designed with a permanently installed main circuit breaker or single set of fuses for disconnecting the number of circuit breakers or fuseholders installed to protect and supply feeders or branch circuits.

SUPPORT AND ARRANGEMENT OF BUSBARS AND CONDUCTORS
408.3

Busbars shall be held firmly in place in the enclosure and shall be arranged in such a way to allow adequate space for conductors to be terminated. Busbars shall be sized with enough capacity to handle the normal currents in amps of the electrical system. In addition, they shall carry safely any type of short-circuit or ground-fault condition.

CONDUCTORS AND BUSBARS ON A SWITCHBOARD OR PANELBOARD
408.3(A)

Conductors and busbars on a switchboard, panelboard, or control board shall be so located as to be free from physical damage. Service sections of such boards shall be separated from the other electrical components. These components shall be properly secured in an approved manner. 

Note, conductors entering a certain section shall terminate in such section, except where it is not practical for control, interconnecting conductors, or other conditions of use.

OVERHEATING AND INDUCTIVE HEATING
408.3(B)

The arrangement of busbars and conductors shall be such as to avoid overheating due to inductive effects. The inductive effect of each conductor is neutralized when grouping all conductors together. To accomplish the minimizing of heating effects, the ungrounded (phase) conductors, grounded (neutral) conductors, and equipment grounding conductors, where used, shall be in the same enclosure, raceway, cable, cord, etc. (See Figure 7-1)

Unfold ↓

You Might Like

Recommended Posts

Share information
[i=s]This post was last edited by paulhyde on 2014-9-15 03:58[/i] These are all great! :Laugh:
hsy Electronics Design Contest
c# wince direct show problem
I want to use C# to make a player on wince, using DirectShowLib. It works on PC, but when running on wince, it shows e436ebb3-524f-11ce-9f53-0020af0ba770 com object cannot be created. Is it because th
二战幸存者 WindowsCE
How to port the program developed by VS2003 to the development board
As the title says, there is no problem with serial communication, but I cannot move the program to the development board for debugging. Could you please help me? Thank you!
stillingermany Embedded System
Hardware IIC issues related to MSP430F5438
In recent days, I have been using the hardware IIC of MSP430F5438 to communicate with FM24CL64. The program used is basically adapted from TI's official routine. The function implemented is to continu
njuedc Microcontroller MCU
CS5513-BSZ
CS5513-BSZ, in SOIC-8 package. Manufacturer: Cirrus Logic Product Category: ADC (Analog-to-Digital Converter) Number of Converters: 1 Number of ADC Inputs: 1 Architecture: Delta-Sigma Conversion Rate:
sweetgril789 TI Technology Forum
About the clock configuration of MSP430F149
[p=19, null, left][font=Verdana, Geneva, Arial, Helvetica, sans-serif][size=13px][color=#000000][backcolor=white]1. Overview[/backcolor][/color][/size][/font][/p][p=19, null, left][font=Verdana, Genev
Jacktang Microcontroller MCU

Recommended Content

可能感兴趣器件

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

About Us Customer Service Contact Information Datasheet Sitemap LatestNews


Room 1530, 15th Floor, Building B, No.18 Zhongguancun Street, Haidian District, Beijing, Postal Code: 100190 China Telephone: 008610 8235 0740

Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京B2-20211791 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号