Technical requirements for variable frequency power supply
1. Rated total capacity of variable frequency power supply: 6000VA,
input single-phase AC: 220V±10%, output three-phase four-wire symmetrical power supply (rated power of each phase 2000VA), the power supply is required to have the ability to be overloaded twice for a short time.
2. Insulation strength of variable frequency power supply: the withstand voltage between the output terminal and the shell and the ground should withstand 3000V AC power frequency for 1 minute without breakdown.
3. Output frequency
1. There are three fixed frequency outputs: 40Hz, 50Hz, 60Hz; the frequency accuracy should be guaranteed to be ±0.05%.
4. The voltage of the variable frequency power supply is fixed to three gears, 250V and 1000V, and the two gears share the same output terminal.
1st gear: rated output 0~250V (referring to the single-phase output voltage when three-phase four-wire) and the output voltage is continuously adjustable, the output current is 8A~2A, and the output characteristics requirements are the same as above.
2nd gear: rated output 0~1000V (referring to single-phase output voltage in three-phase four-wire mode) and output voltage is continuously adjustable, output current is 2A~5mA; output characteristics are the same as above.
5. The power supply has short-circuit protection, overload protection, power device overheating protection, and overload alarm prompt when the maximum current is exceeded (prompting which phase voltage or current is overloaded).
6. Three-phase output characteristics of variable frequency power supply:
1 The output characteristics of the variable frequency power supply should not be affected by whether the power supply load is inductive or capacitive.
2 When the variable frequency power supply is output at non-industrial frequency, it is necessary to ensure that the external power supply load can normally output non-industrial frequency voltage and current signals when it reverses power to the output end of the power supply (reverse current is 50HZ/20A per phase).
3 The variable frequency power supply can output three-phase four-wire symmetrical power supply or single-phase power supply.
7. Variable frequency power supply structure requirements:
integrated structure or split structure: the internal assembly of the power supply must ensure that each device has good anti-transport and vibration performance; the internal components of the power supply are assembled reasonably for easy maintenance; the power control key and the power input and output terminals are installed on the surface of the casing and recessed on the surface of the casing, the power frequency has a clear indicator light, and the bottom of the power supply uses large casters (integrated structure) with self-locking function for easy on-site movement; reasonable handling handles are installed on both sides of the power supply and recessed on the surface of the casing.
8. Harmonic content:
0~250V: ≤3%
0~1000V: ≤3%
9. Output terminal and grounding terminal:
1. Voltage input terminal: U, N,
2. Voltage output terminal: UA, UB, UC, N,
3. Casing grounding terminal: GND
4. Frequency signal output terminal: frequency pulse (5V), ground (5V ground)
Reference address:Technical requirements for variable frequency power supply
1. Rated total capacity of variable frequency power supply: 6000VA,
input single-phase AC: 220V±10%, output three-phase four-wire symmetrical power supply (rated power of each phase 2000VA), the power supply is required to have the ability to be overloaded twice for a short time.
2. Insulation strength of variable frequency power supply: the withstand voltage between the output terminal and the shell and the ground should withstand 3000V AC power frequency for 1 minute without breakdown.
3. Output frequency
1. There are three fixed frequency outputs: 40Hz, 50Hz, 60Hz; the frequency accuracy should be guaranteed to be ±0.05%.
4. The voltage of the variable frequency power supply is fixed to three gears, 250V and 1000V, and the two gears share the same output terminal.
1st gear: rated output 0~250V (referring to the single-phase output voltage when three-phase four-wire) and the output voltage is continuously adjustable, the output current is 8A~2A, and the output characteristics requirements are the same as above.
2nd gear: rated output 0~1000V (referring to single-phase output voltage in three-phase four-wire mode) and output voltage is continuously adjustable, output current is 2A~5mA; output characteristics are the same as above.
5. The power supply has short-circuit protection, overload protection, power device overheating protection, and overload alarm prompt when the maximum current is exceeded (prompting which phase voltage or current is overloaded).
6. Three-phase output characteristics of variable frequency power supply:
1 The output characteristics of the variable frequency power supply should not be affected by whether the power supply load is inductive or capacitive.
2 When the variable frequency power supply is output at non-industrial frequency, it is necessary to ensure that the external power supply load can normally output non-industrial frequency voltage and current signals when it reverses power to the output end of the power supply (reverse current is 50HZ/20A per phase).
3 The variable frequency power supply can output three-phase four-wire symmetrical power supply or single-phase power supply.
7. Variable frequency power supply structure requirements:
integrated structure or split structure: the internal assembly of the power supply must ensure that each device has good anti-transport and vibration performance; the internal components of the power supply are assembled reasonably for easy maintenance; the power control key and the power input and output terminals are installed on the surface of the casing and recessed on the surface of the casing, the power frequency has a clear indicator light, and the bottom of the power supply uses large casters (integrated structure) with self-locking function for easy on-site movement; reasonable handling handles are installed on both sides of the power supply and recessed on the surface of the casing.
8. Harmonic content:
0~250V: ≤3%
0~1000V: ≤3%
9. Output terminal and grounding terminal:
1. Voltage input terminal: U, N,
2. Voltage output terminal: UA, UB, UC, N,
3. Casing grounding terminal: GND
4. Frequency signal output terminal: frequency pulse (5V), ground (5V ground)
Previous article:Combined cooling, heating and power technology
Next article:DS33Z11/DS33Z44 EEPROM Programming Guide
- Popular Resources
- Popular amplifiers
Recommended Content
Latest Analog Electronics Articles
- High signal-to-noise ratio MEMS microphone drives artificial intelligence interaction
- Advantages of using a differential-to-single-ended RF amplifier in a transmit signal chain design
- ON Semiconductor CEO Appears at Munich Electronica Show and Launches Treo Platform
- ON Semiconductor Launches Industry-Leading Analog and Mixed-Signal Platform
- Analog Devices ADAQ7767-1 μModule DAQ Solution for Rapid Development of Precision Data Acquisition Systems Now Available at Mouser
- Domestic high-precision, high-speed ADC chips are on the rise
- Microcontrollers that combine Hi-Fi, intelligence and USB multi-channel features – ushering in a new era of digital audio
- Using capacitive PGA, Naxin Micro launches high-precision multi-channel 24/16-bit Δ-Σ ADC
- Fully Differential Amplifier Provides High Voltage, Low Noise Signals for Precision Data Acquisition Signal Chain
MoreSelected Circuit Diagrams
MorePopular Articles
- LED chemical incompatibility test to see which chemicals LEDs can be used with
- Application of ARM9 hardware coprocessor on WinCE embedded motherboard
- What are the key points for selecting rotor flowmeter?
- LM317 high power charger circuit
- A brief analysis of Embest's application and development of embedded medical devices
- Single-phase RC protection circuit
- stm32 PVD programmable voltage monitor
- Introduction and measurement of edge trigger and level trigger of 51 single chip microcomputer
- Improved design of Linux system software shell protection technology
- What to do if the ABB robot protection device stops
MoreDaily News
- CGD and Qorvo to jointly revolutionize motor control solutions
- CGD and Qorvo to jointly revolutionize motor control solutions
- Keysight Technologies FieldFox handheld analyzer with VDI spread spectrum module to achieve millimeter wave analysis function
- Infineon's PASCO2V15 XENSIV PAS CO2 5V Sensor Now Available at Mouser for Accurate CO2 Level Measurement
- Advanced gameplay, Harting takes your PCB board connection to a new level!
- Advanced gameplay, Harting takes your PCB board connection to a new level!
- A new chapter in Great Wall Motors R&D: solid-state battery technology leads the future
- Naxin Micro provides full-scenario GaN driver IC solutions
- Interpreting Huawei’s new solid-state battery patent, will it challenge CATL in 2030?
- Are pure electric/plug-in hybrid vehicles going crazy? A Chinese company has launched the world's first -40℃ dischargeable hybrid battery that is not afraid of cold
Guess you like
- This week's highlights
- Brushless motor MOS
- [Routine experience of Flathead RVB2601 development board] Part 1: Download the example program successfully, sharing experience!
- Request CKS32F103 information
- Zener diode parameter explanation
- JPEG encoding
- How are the engineers in Hubei and Wuhan doing during this epidemic?
- Labor and technology classes are back. From September, primary and secondary school students will learn to cook, grow vegetables, repair home appliances, etc.
- Why choose voltage mode control for fixed frequency pulse width modulation of power supply?
- I often hear people say not to use tantalum capacitors. Why?