Basic application circuit of AD590 b
Source: InternetPublisher:抄写员 Keywords: Application circuit AD BSP temperature detection Updated: 2020/08/28
Shown is a basic application circuit for the AD590.
Since the AD590 is a current output, a series resistor can convert the output current into voltage. Figure 1-31 (a) is the most
basic application circuit . The output current of AD590 is in Zhan. , the voltage formed on RP is used as the output vo, and RP is used for output trimming.
For example, when Ri+RP=1. OK, at 25℃, the output vo=298. 15 bcA×lk0,=298. 15mV. Figure 1-31
(b) and (c) show the series and parallel applications of AD590 respectively. More than three of them can be connected in series or in parallel at the same time. AD590 series application can be used for multi-point temperature detection
in a small space ; Figure 1-31 (b) The output voltage
is based on the position of the AD590 with the lowest temperature, Figure 1-31 (c) The output voltage is the average of several AD590s, It can improve
the accuracy of multi-point temperature detection .
AD590 is very easy to interface with CMOS digital circuits. It can be connected to gate circuits, analog electronic switches, etc.
Figure 1-31 (d) is a circuit using a NOT gate as an electronic switch for multi-channel temperature detection . The output voltage is affected by Cl,
C2, C3 terminal control. For example, when cl -0, C2=1, C3 =1, the output is AD 590 -1.
- FL52C4 induction electronic greeter
- Homemade air conditioner outdoor unit shutdown indicator
- AD108 frequency multiplier capable of inputting asymmetric square wave
- Oil level indication circuit made by light emitting diode
- Unity-gain buffer circuit composed of MAX4100/MAX4101
- Typical application circuit of LM4911 for dual-channel amplifier
- An amplifier using INA103 to set gain with external resistors
- Load current measurement amplifier composed of INA117
- Human body bioelectric signal preamplifier composed of INA102
- Temperature Compensated Logarithmic Response Feedback Amplifier Circuit (VCA610/OPA620)
- AD7730 digital pressure measurement circuit
- AD7715 internal functional block diagram and pin function diagram
- 350Ω bridge measurement amplifier circuit composed of AD524
- DK-5A, DK-5AD AC power supply control circuit
- Battery charge controller ADP3810/3811 circuit
- LA4500 power amplifier circuit diagram
- AD22050 amplifier circuit
- AD524 type precision instrument amplifier
- AD22103 type temperature sensor circuit
- Using AD586 to generate - 5.000V voltage circuit diagram