XJ01-14 to 20 type auto-coupling step-down starter circuit
Source: InternetPublisher:王达业 Keywords: Starter BSP indicator light Updated: 2021/06/10
XJ01 series autocoupler is suitable for step-down starting of 380V motors with a capacity of 300kW and below. The starter
has protection functions such as overload and voltage loss. The auto-coupling step-down starter is controlled by the time relay to automatically complete the switching on and off
. The starting time (5~120s) is adjustable.
(1) XI01-14~20 type auto-coupling step-down starter starting circuit
circuit is shown in Figure 3-50. It uses two contactors to switch automatically. In the figure, Hi is the full voltage operation indicator light , H2
is the reduced voltage start indicator light, and H3 is the power indicator light .
- Design and selection of electric control valve system drive
- Model rocket launch controller circuit
- How to make a wheeled self-balancing robot using ultrasonic sensors
- A simple door handle touch alarm circuit
- What is a RADAX motor?
- Squirrel cage asynchronous motor reverse braking control circuit
- Design and analysis of wire control circuit
- IGBT modules block overcurrent by controlling the gate
- Design and analysis of touch delay switch circuit composed of CD4011 and CD4001
- Design and analysis of voice control circuit
- Motor forward and reverse control wiring diagram (2)
- Electrical schematic diagram of DC voltmeter input at non-inverting terminal
- Domestic KD8041 integrated phase locked loop
- Proportional frequency discriminator circuit
- Frequency modulator composed of NE566
- Varactor Diode Frequency Modulator
- Audio function generator composed of ICL8038
- Capacitive feedback oscillator circuit
- Voltage-controlled voltage source second-order active low-pass filter circuit
- superheterodyne radio circuit