200PPI to Ethernet and easy-to-control modbusTCP client communication configuration

Publisher:TranquilSilenceLatest update time:2024-09-23 Source: elecfans Reading articles on mobile phones Scan QR code
Read articles on your mobile phone anytime, anywhere

Siemens 200PLC and Easy Control INSPEC software are connected to Siemens S7200 series PLC via Ethernet. Xingda Easy Control PPI-ETH-XD1.0 communication module is used to provide Ethernet communication interface for PLC. Siemens S7200 series PLC equipment informationization Easy Control INSPEC Ethernet communication, through Easy Control INSPEC software to collect real-time production and equipment data of field equipment. The controllers of the main equipment include Mitsubishi, Siemens, Omron and other PLCs, and the communication method adopts Ethernet communication.


On-site situation:

pYYBAGLrfDeAF2q1AAFGMA4UKuY104.jpg

Siemens S7200 series PLC monitoring computer, easy-to-control INSPEC, communication module PPI-ETH-XD1.0

Hardware Hookup

1) Connect Xingda Easy Control PPI-ETH-XD1.0 to Siemens S7200 series PLC;

2) Connect each Xingda Easy Control PPI-ETH-XD1.0 communication module to the LAN network and connect it to the upper monitoring computer.

2. Xingda Easy Control PPI-ETH communication module parameter configuration

As shown in the figure, the module’s IP address is: 192.168.1.188, port number: 102;

poYBAGLrfDeAM2kEAACvuBHX_Xo268.jpg

3. Easy-to-control INSPEC software parameter configuration

1) Create a new channel - select "Ethernet" communication method and fill in the channel name;

poYBAGLrfDeAYI1_AAC7D55rE9s375.jpg

2) In the configuration channel-remote node, fill in the IP address "192.168.1.188" of the Xingda Easy Control PPI-ETH Ethernet module in "IP address", fill in "102" in "IP address", click "Test" to complete the configuration;

poYBAGLrfDeAHBrxAAC_6QrSoX4109.jpg

3) Create a new device - select "Siemens S7200 Ethernet" in PLC and fill in the device name;

pYYBAGLrfDeAYI0HAADhaOY8BKA099.jpg

4) Add variables and test monitoring;

pYYBAGLrfDeABg1CAACaERlYjRw672.jpg


Reference address:200PPI to Ethernet and easy-to-control modbusTCP client communication configuration

Previous article:200ppi to Ethernet without programming to achieve 200 224XP and 200SMART PLC data exchange
Next article:How to solve the problem of electric heating overheating?

Latest Embedded Articles
Change More Related Popular Components

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

About Us Customer Service Contact Information Datasheet Sitemap LatestNews


Room 1530, 15th Floor, Building B, No.18 Zhongguancun Street, Haidian District, Beijing, Postal Code: 100190 China Telephone: 008610 8235 0740

Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号