Problems with single-step debugging of STM8

Publisher:和谐共存Latest update time:2018-09-05 Source: eefocusKeywords:STM8 Reading articles on mobile phones Scan QR code
Read articles on your mobile phone anytime, anywhere

The following problems occur when using STM8 for single-step debugging:

Sometimes the following error message appears: Error:swim error[30007]:swim communication error, as shown below:


Sometimes the following error message appears: Error: swim error [30004]: comm timeout, as shown below:


Cause: A hardware watchdog was set during the development process, causing the watchdog to reset as soon as the program is entered.

Solution: Modify the option byte and set it as software watchdog.

Lessons learned: Do not enable the hardware watchdog during single-step debugging in the future.