Circuit working principle: IC 1 is a digital integrated circuit CD4060. R1, R2, C1 and
the NOT gate inside CD4060 form an RC oscillator. The oscillation period is t≈2.2R2C1≈7.03 s.
When the signal generated by the oscillator accumulates to 1024 times, that is, 7.03 (s) xl 024-2 h
, Ql outputs a high level to trigger IC2 and change the working state. At the same time, Ic resets and
counts again, achieving the purpose of supplying water for 2 hours every 2 hours. Press S once, IC2 is set
, and water can be supplied immediately. Closed S:, water can be supplied for a long time. Press S3 once, IC : is
reset, and the water can be stopped immediately. Close S. , the water can be cut off for a long time. LED is used to show
whether the circuit is working normally, and LED z is used to show the working status. If the circuit encounters a power outage during operation
, the battery will automatically supply power, and the circuit will still count to ensure the regularity of the power supply time
.


EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

About Us Customer Service Contact Information Datasheet Sitemap LatestNews


Room 1530, 15th Floor, Building B, No.18 Zhongguancun Street, Haidian District, Beijing, Postal Code: 100190 China Telephone: 008610 8235 0740

Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号