CAN H short circuit to ground fault analysis

Publisher:PeacefulWarriorLatest update time:2024-04-15 Source: elecfansKeywords:CAN Reading articles on mobile phones Scan QR code
Read articles on your mobile phone anytime, anywhere

CAN H short circuit to ground

When a CAN H short-circuit to ground fault occurs, depending on the fault-tolerance characteristics of the CAN bus, the entire CAN network may be unable to communicate or a related fault code may be generated.


The voltage of CAN H is at 0V, and the voltage of CAN L is also at 0V, but a small voltage change can be seen on the CAN L wire. The bus waveform of CAN H short-circuited to ground is shown in the figure below.

picture

When measuring the voltage, if both CAN H and CAN L voltages are about 0V and there is no open circuit problem, this type of fault has occurred. The CAN H voltage when CAN H is short-circuited to ground is shown in the figure below.

picture

The CAN L voltage when CAN H is short-circuited to ground is shown in the figure below.

picture

Cause of the fault: If the fault is not caused by the short circuit of the CAN H wire to the external ground wire, then this fault may be caused by the damage of the CAN transceiver inside the control module. The fault finding method is the same as above.


Keywords:CAN Reference address:CAN H short circuit to ground fault analysis

Previous article:CAN L short-circuited to ground bus waveform
Next article:How to solve the short circuit fault of CAN H to power supply (positive pole)

Latest Embedded Articles
Change More Related Popular Components

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

About Us Customer Service Contact Information Datasheet Sitemap LatestNews


Room 1530, 15th Floor, Building B, No.18 Zhongguancun Street, Haidian District, Beijing, Postal Code: 100190 China Telephone: 008610 8235 0740

Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号