How to calculate the rise time of a damped double pole

Publisher:ShimmeringStarLatest update time:2012-02-20 Reading articles on mobile phones Scan QR code
Read articles on your mobile phone anytime, anywhere

The LC time constant of this circuit is:

For this type of critically damped two-pole circuit, the 10% to 90% rise time is 3.4 times the LC time constant:

The rise time of 4.8NS shows the problem. We noticed that in the " Degradation of Signal Rise Time ", the 10%~90% rise time of a 300MHZ oscilloscope probe number is 1.1NS, while here, the 3IN ground wire diameter degrades the 10%~90% rise time to 4.8NS.

Reference address:How to calculate the rise time of a damped double pole

Previous article:How Probes Load Circuits
Next article:How to Calculate Ground Loop Inductance