The TMI LabMaster System 80-91 Peel Tester is a programmable device developed based on Windows. It is used to test the viscosity of tapes, labels, some medical supplies, and sealing materials. It has real-time collection of test raw data and an intuitive user-friendly interface for test results.
It can provide multiple test standards, such as GB/T 1040.3-2006, GB/T 17200, GB/T 2790, GB/T 2791, GB/T 2792, GB/T 2358, ASTM D 3330, FINAT FTM 1, 2, 3, 4, TLMI L-IA1 and L-IA2, PSTC-1, 3, 4 and other standards to ensure the accuracy of the equipment test data. It can choose three different sensors 0~500g (1.1 lb), 0~4540g (10 lb), 0~11339g (25 lb). The maximum width of the test sample is 5cm (2 in), and the maximum peeling length is 30.28cm (12 in). The speed range is 1.27-4064cm/min (0.5-1600 in./min).
Technical Parameters:
Sensor: Replaceable sensor: 0~500g (1.1 lb), 0~4540g (10 lb), 0~11339g (25 lb)
Speed range: 1.27-4064 cm/min (0.5-1600 in./min)
Measuring stroke: Maximum stroke 30.28 cm (12 in)
Net weight: 40 kg (88 lb)
Equipment size W×D×H: 1461mm×203mm×553mm (57.5 in.×8 in.×21.75 in)
Power supply: 120/240 VAC 50/60 Hz
Previous article:Indicators of electric detonator tester_Access to test components of electric detonator tester
Next article:Performance characteristics of the electric detonator tester calibration device
- Popular Resources
- Popular amplifiers
- From probes to power supplies, Tektronix is leading the way in comprehensive innovation in power electronics testing
- Seizing the Opportunities in the Chinese Application Market: NI's Challenges and Answers
- Tektronix Launches Breakthrough Power Measurement Tools to Accelerate Innovation as Global Electrification Accelerates
- Not all oscilloscopes are created equal: Why ADCs and low noise floor matter
- Enable TekHSI high-speed interface function to accelerate the remote transmission of waveform data
- How to measure the quality of soft start thyristor
- How to use a multimeter to judge whether a soft starter is good or bad
- What are the advantages and disadvantages of non-contact temperature sensors?
- In what situations are non-contact temperature sensors widely used?
- LED chemical incompatibility test to see which chemicals LEDs can be used with
- Application of ARM9 hardware coprocessor on WinCE embedded motherboard
- What are the key points for selecting rotor flowmeter?
- LM317 high power charger circuit
- A brief analysis of Embest's application and development of embedded medical devices
- Single-phase RC protection circuit
- stm32 PVD programmable voltage monitor
- Introduction and measurement of edge trigger and level trigger of 51 single chip microcomputer
- Improved design of Linux system software shell protection technology
- What to do if the ABB robot protection device stops
- Huawei's Strategic Department Director Gai Gang: The cumulative installed base of open source Euler operating system exceeds 10 million sets
- Download from the Internet--ARM Getting Started Notes
- Learn ARM development(22)
- Learn ARM development(21)
- Learn ARM development(20)
- Learn ARM development(19)
- Learn ARM development(14)
- Learn ARM development(15)
- Analysis of the application of several common contact parts in high-voltage connectors of new energy vehicles
- Wiring harness durability test and contact voltage drop test method
- EEWORLD University Hall ---- Zhou Gong Series Lectures - Temperature Instruments
- Is there any impact if the power supply is connected using soldered wires during PCB wiring?
- In wireless laser target shooting applications, which solution is better, 2.4G Bluetooth or Sub-G wireless communication?
- State machine model of microcontroller program
- TI C2000 series DSP Bootloader CAN online upgrade program and forgotten CSM password decryption technology
- Annual salary of 400,000! OPPO spends big to recruit chip talents
- Just 5 steps to teach you how to add GPIO buttons!
- 【GD32L233C-START Review】+Unboxing
- BK3432 development board user guide, BK3432 BLE4.2 chip development board
- EuroPython will be held online on July 26, 2021