EEWORLDEEWORLDEEWORLD

Part Number

Search

BZV18/C0133/03

Description
Mains Power Connector, 1A, 250VAC, Female and Male
CategoryThe connector    The connector   
File Size42KB,1 Pages
ManufacturerBULGIN
Websitehttp://www.bulgin.co.uk/
Environmental Compliance  
Download Datasheet Parametric View All

BZV18/C0133/03 Overview

Mains Power Connector, 1A, 250VAC, Female and Male

BZV18/C0133/03 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerBULGIN
Reach Compliance Codecompliant
Connector typeMAINS POWER CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderFEMALE AND MALE
Contact materialNOT SPECIFIED
Coupling typeSNAP
DIN complianceNO
IEC complianceNO
MIL complianceNO
Power Connector Ratings1A, 250VAC
Manufacturer's serial numberBZV18
Total number of contacts6
Polysnap
®
Power Inlet Modules
IEC Inlet - High Performance Filter
EMI filter options for
Polysnap modules BZV03,
BZV04, BZV09, BZV10,
BZV17, BZV18, BZH09,
BZH10, BZH17, BZH18,
BZM27, BZM28
PX0575 style IEC inlet
Using PS07/A style filter
High Performance
Attenuation Filter
Bxxxx/Cxx x x / xx
Polysnap Part No.
From Polysnap Selection
Filter Type
Rating
L/C Circuit
1 = Version 1
3 = Version 3
Additional
Components
0 = None
1 = Bleed (R) Resistor
2 = Surge (VDR) Protection
3 = “R” plus “VDR”
Polysnap Part No.
From Polysnap Selection
C = High Performance 01 = 1A
03 = 3A
06 = 6A
10 = 10A
Rating
1 AMP
3 AMP
6 AMP
10 AMP
Version
1
2
3
1
2
3
1
2
3
1
2
3
L1
2 x 2.8mH
2 x 10mH
2 x 1.8mH
2 x 3mH
2 x 0.7mH
2 x 0.7mH
Cx
2 x 15nF
2 x 47nF
2 x 15nF
2 x 47nF
2 x 15nF
2 x 47nF
Cy
2 x 2.2nF
2 x 2.2nF
2 x 2.2nF
2 x 2.2nF
2 x 2.2nF
2 x 2.2nF
Part No. Example
BZH09/C1033/03 =
BZH style Polysnap module with PX0575 IEC
power inlet, filter rated at 10 amps, L/C circuit
version 3 (L1 = 2 x 0.17mH, Cx = 2 x 47nF,
Cy = 2 x 2.2nF), with bleed resistor and surge
protection device fitted, 6.3mm tabs and red
neon indicator.
2 x 0.17mH
2 x 47nF
2 x 2.2nF
Filter Specification
Max. Working Voltage:
Earth Leakage Current:
Temperature Range:
Max. Ambient Temp.:
(@ Full Load)
Test Voltage:
Approvals:
250V a.c. 50-400Hz
<0.35mA (250V. 50Hz)
–25ºC to +85ºC
40ºC (derate linearly to 0A @ 85ºC)
2700V d.c. 2 secs. Lines to Earth
1100V d.c. 2 secs. Live to Neutral
Attenuation Curves:
See PS07/A filter, page 119
www.Bulgin.co.uk
Tel: +44 (0) 20 8594 5588
77
Polysnap
®
Threshold voltage question
Why is the threshold voltage Ut less than 0 when it jumps from a high level to a low level, and greater than 0 when it jumps from a low level to a high level?...
msddw Analog electronics
How to view ADI data sheet information sharing
How to view ADI data sheet information sharing...
勤奋 ADI Reference Circuit
Anlu SparkRoad domestic FPGA evaluation [Problem feedback] ASUS win10 installation Anlu Jtag driver problem
[i=s]This post was last edited by 1nnocent on 2022-7-29 10:44[/i]Although there was a problem when installing the Anlu Jtag driver at home, the problem was solved by checking TD_User_Guide_V4.6. When ...
1nnocent Domestic Chip Exchange
I need help from the teacher, the communication failure of the adaptive cruise control is
11 Teana installed 19 Teana adaptive cruise, new gateway, Adas module, millimeter wave radar, communication failure after connection, skip bcm, hardware connected to ecu communication is normal, need ...
hbhbhb162 Automotive Electronics
What is the difference between the AFE module in the automotive BMS and the general metering chip?
I would like to ask everyone on the forum, generally automotive BMS is composed of AFE+MCU+other communication modules. I would like to ask why BMS does not use the existing energy metering chip but u...
fhymz Analog electronics
After BlueRNG-LP turns off broadcasting, the virtual timing cannot be awakened
Hardware: STEVAL-IDB011V development board Software: Start two virtual timers, one to read peripherals and one to turn off broadcasting sensorTimerHandle.callback = SensorUpdateTimeoutCB;ret = HAL_VTI...
hometown ST - Low Power RF

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号