Remote RTD temperature sensing-voltage and current output conversion circuit
Source: InternetPublisher:念慈菴 Keywords: Temperature sensing voltage and current conversion circuit BSP Updated: 2020/01/28
When the distance between the RTD temperature sensor and the amplifier is relatively long,
issues such as the sensor's lead resistance and the vulnerability of the leads to interference cannot be ignored. The circuit shown in the figure can solve this problem.
This circuit uses a voltage-4-20mA current converter XTR103. XTR103 is a dedicated signal processing circuit for RTD.
It integrates Rrl'D linearization circuit internally and expands the power supply voltage range to +9~+40V.
XTR103 outputs two 0.8mA current sources. The current sources are driven by VT2 and then added to the RTD to avoid
attenuation caused by the line and suppress line interference. The function of Rh is similar to that of R in XTR101. The function is exactly the same: limiting
the maximum value of the output current. Rini is a linear adjustment resistor, which can change the resistance value to change the linearity. The output signal
gets a current of 4~20mA after being connected to the external transistor VT1. RCV420 is a 4-20mA current-to-voltage dedicated converter (
will be introduced in "3" of this section), which outputs a 0~5V voltage after conversion.
- Causes and solutions for noise in digital Class D amplifiers
- Transfer characteristics of BJT, how to apply Shockley equation?
- Tutorial on building a NOT gate using BJT transistors
- How to install the accelerometer
- What types of force sensors are there?
- Introduction of TDA4863J/4863AJ TV field scanning IC
- Experimental circuit based on 4040 binary adder counter
- Pulse frequency multiplier composed of gate circuit (CD4011)
- Method for obtaining second reference signal using CMOS pointer-type quartz electronic clock integrated circuit
- Simple and easy to make energy-saving LED flashlight
- Electronic thermometer circuit
- Chicken supplementary light to increase egg production rate circuit
- Egg heating control circuit
- Soil water shortage prompt circuit
- Farmland drainage automatic control circuit
- Integrated synchronous detector composed of analog multiplier MC1596
- Amplitude modulation circuit composed of MC1496
- Wien bridge oscillator circuit
- Voltage-controlled voltage source second-order active low-pass filter circuit
- High and low frequency signal generator circuit