Home > Basic Circuits > Clamp current probe compensator

Clamp current probe compensator

Source: InternetPublisher:明天见 Keywords: WIDTH Updated: 2021/05/04

Clip-on " current probes " such as the Tektronix P6021 are very useful for displaying current waveforms on an oscilloscope. Unfortunately, there are always some limitations to low-frequency response, as shown in the figure: For the P6021, the sensitivity range is 2mA/mV, with a 6dB per octave roll-off below 450 Hz.