Multifunctional motor protection circuit
Source: InternetPublisher:偷熊计划 Keywords: Protection circuit motor protection IDE Updated: 2020/05/18
Working principle of the circuit: During normal operation, the voltage at both ends of the current sensing resistor is
divided by R2 and RP, and is used as the input signal of IC 4. IC4, R3~ Rg, C7~ Cl,, VDs~
VD, etc. constitute a half-wave rectified linear AC/DC conversion amplifier with average response.
During the positive half cycle, the signal flow is: IC4-CS-VD7-÷R6_+岛_+RP2-÷GND.
In the negative half cycle, the current leakage circuit is: GND-*RP2- R7- VD6_÷Cs- lC4.
The output passes through R8, cl, and Rg to obtain an average DC voltage that is linearly proportional to the input effective value.
This voltage passes through S. (S. is placed at the measuring end during normal operation) Enter the A/D converter
IC , and correctly adjust R)l and RP2, so that the LED can accurately display
the primary current of the current transformer BT. When used to protect a three-phase AC motor, this circuit can be used to detect
the current of any one of the three phases of the motor.
- Design and production of radio remote control fan stepless speed regulator
- Amplitude and phase detection leakage protection device designed and manufactured using PIC16C711A
- Design and production of no-load automatic power-off device for household power supply
- Magnetic door and window anti-theft alarm
- Home wireless burglar alarm circuit
- Simple disconnection burglar alarm
- Disconnection anti-theft protection circuit
- Refrigerator Thermostat Replacement Device
- A gas stove igniter circuit
- Household flower pot automatic watering device
- Low voltage circuit breaker protection circuit a
- Thyristor silicon stack protection circuit c
- Capacitor motor phase failure protection circuit
- Asynchronous motor protection circuit composed of photoelectric coupler
- AC electronic voltage regulator overvoltage protection circuit
- Thyristor type overcurrent protection circuit 6
- Thyristor overcurrent protection circuit one a
- Mains overvoltage protection circuit
- KGLF-31F3 automatic excitation device circuit b
- Overcurrent protection circuit for generator low voltage start b