Calculation formula for coaxial cable

Publisher:SerendipityGlowLatest update time:2011-06-13 Reading articles on mobile phones Scan QR code
Read articles on your mobile phone anytime, anywhere

The calculation formula is shown in Figure 4.29

The diameter of the inner conductor is D1

The inner diameter of the shielding shell is D2 (D2>D1)

The effective relative dielectric constant is ∑R

(For solid core cables , ∑R is equal to the dielectric constant of the insulating material. For foam, spiral wound or other cores containing a lot of air, ∑R will be smaller)

Impedance (Ω):

Propagation Delay (PS/IN):

Reference address:Calculation formula for coaxial cable