Access control system technical indicators

Publisher:云淡风轻2014Latest update time:2011-04-16 Reading articles on mobile phones Scan QR code
Read articles on your mobile phone anytime, anywhere

The access control system adopts a modular design concept. The card reader control module controls each other with the RS485 bus structure, and then can be directly connected to the main control computer through the RS485/232 converter, or connected to the local area network through the TCP/IP interface. The card reader control module connects the card reader, electric lock, door opening button and other components to form a basic access control unit. When using, just keep the induction card in front of the card reader for a while to complete the door lock opening and data recording. The system not only has daily operation functions, but also is equipped with a complete file management system and query report and system maintenance functions, which is convenient for management personnel to use freely.

The contactless card access control management system integrates computer, mechatronics and contactless card technology. It controls the opening of door locks through cards, realizes the "dialogue" function between cards and locks, and opens a new concept of access control management. Split access control can be based on customer engineering requirements. The access control controller can control up to 128 doors, providing managers with a safe, fast and automated management mode and bringing great convenience to users.

System features:

Authorized use: Only cards authorized by the system can be issued instructions to the electric door lock within the valid time period to allow the cardholder to pass. The manager can add, modify and cancel the passage time period as needed. Easy to use: When the cardholder

passes through the channel, as long as the card stays in front of the card reader for a while, without contact, the data can be read, compared, stored and whether to issue an unlocking instruction and other corresponding work can be completed within 0.2 seconds. Safe and easy to use: The

card number is unique, the read-write and security performance that is not easy to imitate, the ability to adapt to the environment is strong and durable.

System function:

Flexible configuration, with rich expansion functions

It adopts the time period management method, with multiple time period attributes such as normally open and normally closed.

Large-capacity event record, can work independently without network connection.

The system is easy to install and operate.

Convenient maintenance, backup, clearing and recovery of data are instant and ready to use.

Statistical reports can be queried at any time, which is efficient, safe and reliable. The report output methods are flexible, including print preview, text mode, export to excel and direct printing.

Convenient equipment/data management, data can be collected at any time, and logs can be recorded, saved and cleared.

The system management host can be connected to the local area network, and remote monitoring of entrances and exits and information sharing can be achieved through the network.

Access control system composition and products:

computer and authorization management software, contactless IC card access control reading and writing control unit, card issuer, electric lock, induction IC card, etc.

The product series includes

☆ integrated access control

☆ access control reader

☆ multi-door controller

☆ offline access control

☆ embedded access control.

Integrated access control:

integrated access control integrates control and reading and writing, and is suitable for use by offices and other departments with general security requirements. When the cardholder passes through the control door, he only needs to shake the card in front of the card reader without contact, and the corresponding work such as reading, comparing, storing and issuing unlocking instructions can be completed within 0.2 seconds. The read-write controller is fully encapsulated and suitable for open-air environments. The controller has its own 485 interface and is easy to connect to the Internet.

Main parameters
Card type LEGICIM256IM1024IM4096mifare1mifarelight

Communication interface RS232RS485

Data transmission rate 9600bps-11520bps

Read and write time less than 0.2 seconds

Maximum record capacity 32768 items

Input power 12VDC

Power frequency 50HZ

Input current 200MA

Ambient temperature 0-50℃

Relative humidity 0-95%RH

Static power consumption 0.6W

Dynamic power consumption 1.2W (maximum)

Read and write distance 0-10cm

Access control reader:

The product appearance adopts Italian design style, not only the lines are smooth and simple, but also the user can arbitrarily match the combination shell according to his own individual needs. The dark blue bottom shell is matched with blue, gray, white, green and other colors, which reflects the bright and elegant style while providing users with more flexible choice space, thus highlighting the product nature of "technology is people-oriented".

The card reader is divided into ORIS-26, ORIS-485 and ORIS-232 models according to the protocol, that is, it supports Wiegand 26-bit and standard 485/232 communication protocols. When used with the controller, it can be widely used in various types of access control, attendance and parking systems.

Main parameters

Card type LEGICIM256IM1024IM4096mifare1mifarelight

Communication interface RS232RS485

Data transmission rate 9600bps-11520bps

Read and write time less than 0.2 seconds

Maximum record capacity 32768

Static power consumption 0.6W

Dynamic power consumption 1.2W (maximum)

Read and write distance 5-10cm

LED brightness Three-color display

Buzzer

Card reading/alarm display

Multi-door controller:

In the actual demand for access control products, customers often need to control access control for multiple entrances and exits. In view of this, Lilin Company has focused on developing multi-door controller products. Its biggest feature is that by connecting a controller with the access control reader at each door, the purpose of controlling multiple doors can be achieved, thereby saving the cost of purchasing multiple access control controllers and reducing costs. The multi-door controller is flexible in application and can be compatible with various readers and writers. It can control two doors up to eight or sixteen doors, providing customers with more flexible choices.

Functional features:

→Can control 2 to 8 doors

→Can support network remote door opening and closing

→Can be connected to the network or run offline, flexible to use

→With duress alarm function

→With anti-dismantling alarm function

→With multiple function expansion interfaces to facilitate system application

Offline access control:

Offline access control is mainly suitable for technical applications with small card usage or no real-time requirements for data. Data upload/download is carried out using induction cards as the medium. Every time a card is swiped on the access control machine, the access control machine will write the swipe time back on the induction card. Each induction card can store about 200 swipe records. The card will be taken back at regular intervals and the card issuer will collect data.

Basic technical indicators

Entry method: swipe card, swipe card + password

Status monitoring: door status (open/closed)

Electric lock: Can connect various types of normally open, normally closed and electric control locks and electromagnetic locks

Memory: 32K~512K

I/O port: two relay output ports, two digital ports

Power supply: DC9~16V power supply

Communication interface: RS485

Sensing distance: 5~10cm,

sensing speed: 0.15 seconds

Communication baud rate: 9600, N, 8, 1

LCD display with digital and functional keyboard

Embedded access control:

basic technical indicators

Entry method: card swipe, card swipe + password

Status monitoring: door status (open/closed)

Electric lock: can be connected to various types of normally open, normally closed and electric control locks and electromagnetic locks

Memory: 32K~512K

I/O port: two relay output ports, two digital inputs

Power supply: DC9~16V power supply

Communication interface: RS485

Sensing distance: 5~10cm,

sensing speed: 0.15 seconds

Communication baud rate: 9600, N, 8, 1 (fengminxing)

Reference address:Access control system technical indicators

Previous article:Design, manufacture and debugging of 30.275MHz FM wireless intercom
Next article:Wireless network applied to access control system technology

Latest Analog Electronics Articles
Change More Related Popular Components

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

About Us Customer Service Contact Information Datasheet Sitemap LatestNews


Room 1530, 15th Floor, Building B, No.18 Zhongguancun Street, Haidian District, Beijing, Postal Code: 100190 China Telephone: 008610 8235 0740

Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号