Why are instrumentation amplifiers so often misunderstood? The input offset voltage error of an op amp is not difficult to understand. The definition of op amp open-loop gain has not changed. Simple methods for op amp common-mode rejection (CMR) have been around since the dawn of the op amp era. So, what’s the problem?

Three-op-amp instrumentation amplifier circuit

Fig. 1. A three-op-amp instrumentation amplifier, where VCM is the common-mode voltage and VDIFF is the differential input of the same instrumentation amplifier.

The common CMR equation for single op amps and instrumentation amplifiers is as follows:

Equation 1

In this equation, G is equivalent to the system gain, VCM is the changing voltage applied to the system input relative to ground, and VOUT is the change in system output voltage relative to the changing VCM value.

In terms of CMR, the internal activity of the op amp is simple, and its offset voltage variation is the only concern. In the case of an instrumentation amplifier, there are two factors that affect the CMR of the device. The first and most important factor involves the balance of the resistor ratios of the third amplifier (Figure 1, A3). For example, if R1 equals R3 and R2 equals R4, the CMR of the ideal three-op-amp instrumentation amplifier is infinite. However, we have to return to the real world and study the relationship between R1, R2, R3, and R4 and the CMR of the instrumentation amplifier.

Specifically, it is critical to match R1:R2 with R3:R4. Combined with A3, these four resistors subtract and gain the signal from the outputs of A1 and A2. Mismatches between the resistor ratios create errors at the output of A3. Equation 2 creates CMR errors with respect to these resistor relationships:

Equation 2

For example, if R1, R2, R3, and R4 are close to the same value, and R3:R4 equals 1.001 of R1/R2, then this 0.1% mismatch will result in a degradation of the instrumentation amplifier’s CMR from the ideal level to the 66dB level.

According to Equation 1, the instrumentation amplifier CMR increases as the system gain increases. This is a very good characteristic. Equation 1 may motivate the instrumentation amplifier designer to ensure that there are many gains available, but this approach has certain limitations. A1 and A2 open-loop gain error and noise. The open-loop gain of the amplifier is equal to 20log(ΔVOUT/ΔVOS). As the gain of A1 and A2 increases, the amplifier open-loop gain offset error also increases. The output amplitude variation of A1 and A2 generally covers the supply rails. At higher instrumentation amplifier gains, the open-loop gain error and noise of the op amp dominate. Through the RSS formula, these errors reduce the instrumentation CMR at higher gains. Therefore, you can see that the CMR performance of the instrumentation amplifier tends to reach a maximum value at higher gains.

Therefore, from a CMR perspective, the instrumentation amplifier behaves like a system with CMR errors induced in all parts of the device at different system gains.

Keywords:Instruments Reference address:Instrumentation Amplifier Misconceptions and How to Correct Them

Previous article:Transformer Winding for Inverter
Next article:IC Design Experience of Microprocessor Master

Latest Analog Electronics Articles
Change More Related Popular Components

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

About Us Customer Service Contact Information Datasheet Sitemap LatestNews


Room 1530, 15th Floor, Building B, No.18 Zhongguancun Street, Haidian District, Beijing, Postal Code: 100190 China Telephone: 008610 8235 0740

Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号