In response to the current situation where air conditioning in equipment rooms accounts for a large proportion of total power consumption, Datang Telecom has used advanced refrigeration and heat exchange technologies to launch the "Datang Intelligent Fresh Air Energy Saving System" and "Datang Intelligent Heat Exchange Energy Saving System" that use natural cooling sources to replace part of mechanical refrigeration, as well as energy-saving intelligent air-conditioning appliances for base station air conditioners.
At present, the shortage of electric energy is becoming increasingly prominent, and energy conservation and consumption reduction has become a hot topic of concern to the whole society. The "Outline of the 11th Five-Year Plan" of the State proposes that during the "11th Five-Year Plan", my country should achieve a goal of reducing energy consumption per unit of GDP by 20%, and it has become an important indicator for assessing the performance of governments at all levels. To this end, the state has successively issued relevant policies and regulations such as the "Energy Conservation Law of the People's Republic of China", "Electricity Conservation Management Measures", and "Notice of the General Office of the State Council on Carrying out Resource Conservation Activities", encouraging various power-consuming enterprises to increase their efforts in energy-saving technology transformation.
In order to respond to the national call and assume the social responsibility that enterprises should have, major domestic telecom operators have formulated energy conservation and emission reduction plans and goals. China Mobile has established an "Energy Conservation Office" and a "Green Action Group" to coordinate and manage energy conservation and emission reduction work, and launched a "Green Action Plan"; China Unicom has established an energy conservation and emission reduction leadership group, held an energy conservation experience exchange meeting, and put forward specific energy conservation and emission reduction goals for 2008; China Telecom also started energy conservation and emission reduction issues early, and successively issued the "China Telecom Data Center Room Power Supply and Air Conditioning Environment Design Specifications", "Energy Conservation Implementation Plan", and "China Telecom Energy Conservation Work Guidance".
According to authoritative statistics, the power consumption of communication rooms is the main energy consumption of telecom operators, and air conditioning energy consumption generally accounts for 20% to 45% of the energy consumption of communication rooms, and some even reach more than 60%. Therefore, under the premise of ensuring the normal operation of communication equipment, energy saving should first start with air conditioning.
Product Performance Introduction
1. Datang Intelligent Air Conditioner
How it works
The energy saver adopts real-time automatic temperature compensation technology and temperature range control technology, and uses semiconductor refrigeration technology - refrigeration chip inside. Through the program control of the host, it releases cold (heat) in time to adjust the temperature around the air conditioner's temperature sensor, thereby controlling the operating condition of the compressor.
Names of the various parts of the power saver
(1) Temperature compensator (2) Power cord (3) Cooling and heating conversion switch (4) Temperature sensor (5) Temperature setting and alarm query button (6) Display
Product use location:
Communication room/base station
Product Applicable Conditions
It is used in base stations or computer rooms equipped with civil comfort air conditioners.
Product Features
When this product is installed in an air conditioner, the energy-saving benefits will not be affected by the weather when the air conditioner is running. It has energy-saving effects in all seasons, reduces the running time of the air conditioner, and the annual average power saving rate reaches 15%-35%.
Product advantages and features
(1) After installing and using the air conditioner, it will not have any impact on the environment of the base station/computer room;
(2) The energy-saving effect is not affected by the weather; the power-saving effect is more obvious in the hot season;
(3) Installation/maintenance is simple and quick, and can be completed by non-professionals in about 10 minutes; the original maintenance of the air conditioner does not change during use;
(4) Safe and reliable, it will not cause any damage to the air conditioner and equipment in the computer room during installation and use; it will improve the startup and operation characteristics of the air conditioning equipment, effectively protect the air conditioning compressor, and extend the service life of the air conditioner.
2. Datang Intelligent Fresh Air System
How it works
In seasons or periods when outdoor temperatures are low, the best energy-saving solution for computer room air conditioning is to introduce outdoor low-temperature fresh air into the computer room instead of using air conditioners to regulate the room temperature.
Schematic diagram of Datang intelligent fresh air system
The specific approach is: install fresh air units and exhaust fans in the computer room. In seasons or time periods when the outdoor temperature is lower than the critical temperature (the supply and exhaust air volume is designed to ensure that the indoor temperature remains within the specified range), the intelligent control host stops the operation of all air conditioners through the air conditioner peripheral interface according to the set program, and starts the supply and exhaust fans in sequence to introduce outdoor low-temperature fresh air into the computer room.
Product use location:
Communication room/base station
Product Applicable Conditions
(1) Access network room/base station with high power consumption.
(2) Install a fresh air energy-saving system in a computer room/base station with good ventilation conditions and an ideal surrounding environment.
(3) It is not advisable to install fresh air energy-saving systems on dusty roads or roads, or around dusty factories and plants such as cement plants and building material processing plants, to ensure that the filter replacement cycle is greater than 30 days.
(4) It is not advisable to install fresh air energy-saving systems in computer rooms/base station access network rooms with relatively high humidity.
(5) It is not suitable for computer rooms that have high requirements for environmental cleanliness.
Product Features
Install this product in the base station/computer room and link it with the air conditioner. When the conditions for the fresh air unit to operate are met, the air conditioner will be turned off and the air conditioner will be used to adjust the temperature of the base station/computer room. This saves electricity and extends the service life of the air conditioner compressor, saving the company's operating costs. The annual electricity saving rate is 20%-60%.
Product advantages and features
When installing the equipment, the vents abandoned the traditional practice of opening square holes on the walls of the machine room, and eliminated the potential safety hazards caused by the openings, effectively solving problems such as base station anti-theft and small animal intrusion. Using temperature and humidity sensors with excellent performance, the linkage between the fresh air unit and the air conditioning unit is completely controlled by temperature, so the power saving rate of the fresh air unit is completely determined by the accuracy of the temperature and humidity sensors. The filter of the fresh air unit is specially treated, which is very convenient to disassemble and clean. It can be reused after cleaning, reducing the cost of operation and maintenance. The air inlet valve and exhaust valve are specially treated to be connected to the wall, which can completely isolate the indoor and outdoor air to meet the requirements of gas fire extinguishing.
3. Datang Intelligent Heat Exchange System
How it works
Taking the outdoor natural environment as the cold source, when the outdoor air temperature is lower than the indoor temperature to a certain extent, the outdoor fresh air is heat exchanged with the air in the computer room through corresponding technical means to take away the heat of the computer room, so as to achieve the purpose of lowering the temperature of the computer room, thereby reducing the use time of the air conditioning equipment and saving electricity. The isolation heat exchange method is adopted to ensure the air temperature requirements of the computer room through the sensible heat exchange between indoor and outdoor air. Since the indoor and outdoor air are isolated from each other, the cleanliness of the indoor air is not affected by the outdoor air.
Schematic diagram of Datang intelligent heat exchange system
Product use location:
Communication room/base station
Product Applicable Conditions
(1) There should be a large temperature difference between the external environment temperature and the set temperature of the communication room (recommended to be above 10°C).
(2) Areas where the outdoor environment is not suitable for installing a direct fresh air introduction system.
Product Features
Install this product in the base station/computer room and link it with the air conditioner. When the conditions for the fresh air unit to operate are met, the air conditioner will be turned off and the air conditioner will be used to adjust the temperature of the base station/computer room. This saves electricity and extends the service life of the air conditioner compressor, saving the company's operating costs. The annual electricity saving rate is 20%-40%.
Effects
The products have been successfully applied in Henan, Tianjin, Jiangsu, Guangdong, Anhui, Shandong, Shaanxi, Hebei, Guangxi and other provinces and cities, with good power-saving effects, with power-saving rates above 18% and the highest rate reaching 60%.
The base station of the Baisong Building of Linfen Mobile in Shanxi Province is located in the urban area of Linfen City. It is a representative base station in Linfen City. The power consumption of this station has always been outstanding. Therefore, Datang Telecom designed a unique overall power saving solution for the computer room, which is simple and convenient. Within one week of the installation of Datang's intelligent power saver, the base station saved more than 100 kWh of electricity, an average of more than 20 kWh per day, achieving the purpose of energy conservation, emission reduction and cost saving, and the power saving rate reached more than 30%.
The telecommunications room in Huangshan City, Hefei Province, is located in the suburbs of Huangshan City. It is a representative room in Huangshan City. The power consumption of this station has always been prominent. Therefore, Datang Telecom designed a unique overall power-saving solution for this room based on the characteristics of this room being located in the south of the Yangtze River, but in the mountainous area, with fresh air and large temperature difference between day and night. In the 5 days after the installation of the Datang intelligent fresh air system, the base station saved more than 500 degrees of electricity, an average of more than 100 degrees of electricity per day, achieving the purpose of energy conservation, emission reduction and cost saving, and the power saving rate reached more than 60%.
Previous article:Design of 0°~360° inclination sensor based on MAD2020E acceleration
Next article:Ultra-thin audio and video interface solutions for notebooks/netbooks
- Popular Resources
- Popular amplifiers
- Molex leverages SAP solutions to drive smart supply chain collaboration
- Pickering Launches New Future-Proof PXIe Single-Slot Controller for High-Performance Test and Measurement Applications
- CGD and Qorvo to jointly revolutionize motor control solutions
- Advanced gameplay, Harting takes your PCB board connection to a new level!
- Nidec Intelligent Motion is the first to launch an electric clutch ECU for two-wheeled vehicles
- Bosch and Tsinghua University renew cooperation agreement on artificial intelligence research to jointly promote the development of artificial intelligence in the industrial field
- GigaDevice unveils new MCU products, deeply unlocking industrial application scenarios with diversified products and solutions
- Advantech: Investing in Edge AI Innovation to Drive an Intelligent Future
- CGD and QORVO will revolutionize motor control solutions
- Innolux's intelligent steer-by-wire solution makes cars smarter and safer
- 8051 MCU - Parity Check
- How to efficiently balance the sensitivity of tactile sensing interfaces
- What should I do if the servo motor shakes? What causes the servo motor to shake quickly?
- 【Brushless Motor】Analysis of three-phase BLDC motor and sharing of two popular development boards
- Midea Industrial Technology's subsidiaries Clou Electronics and Hekang New Energy jointly appeared at the Munich Battery Energy Storage Exhibition and Solar Energy Exhibition
- Guoxin Sichen | Application of ferroelectric memory PB85RS2MC in power battery management, with a capacity of 2M
- Analysis of common faults of frequency converter
- In a head-on competition with Qualcomm, what kind of cockpit products has Intel come up with?
- Dalian Rongke's all-vanadium liquid flow battery energy storage equipment industrialization project has entered the sprint stage before production
- New breakthrough! Ultra-fast memory accelerates Intel Xeon 6-core processors
- New breakthrough! Ultra-fast memory accelerates Intel Xeon 6-core processors
- Consolidating vRAN sites onto a single server helps operators reduce total cost of ownership
- Consolidating vRAN sites onto a single server helps operators reduce total cost of ownership
- Allegro MicroSystems Introduces Advanced Magnetic and Inductive Position Sensing Solutions at Electronica 2024
- Car key in the left hand, liveness detection radar in the right hand, UWB is imperative for cars!
- After a decade of rapid development, domestic CIS has entered the market
- Aegis Dagger Battery + Thor EM-i Super Hybrid, Geely New Energy has thrown out two "king bombs"
- A brief discussion on functional safety - fault, error, and failure
- In the smart car 2.0 cycle, these core industry chains are facing major opportunities!
- Commonly used anti-collision algorithms in RFID systems
- Do you know what tools are needed to develop DSP projects?
- Configuration issues of IAR project path and header file path
- switch
- The clock configured by STM32CubeMX is inaccurate?
- Industrial control uses wireless communication modules, efficiency first
- MicroPython now supports Ethernet peripherals on ST development boards
- [NXP Rapid IoT Review] NO.2 Online IDE-----Easy to use, easy programming
- Experts reveal: Toyota Prius gasoline/electric hybrid
- 【XMC4800 Relax EtherCAT Kit Review】+ Getting Started with DAVE, WINUSB APP Application Experience