The anesthesia/EEG depth of consciousness monitoring system is a new type of EEG depth of consciousness monitoring system developed by a research group at the Medical University of Hannover in Germany. It collects and analyzes real-time EEG signals at any position of the brain through ordinary ECG electrodes, and displays the patient's anesthesia/depth of consciousness status on a color touch screen after automatic classification. It guides the dosage adjustment of individual anesthetics/sedatives, making anesthesia/depth of consciousness monitoring more economical, simple, accurate and safe. It is specially used in the fields of consciousness monitoring such as operating rooms, ICUs, and neurosurgery.
Its main advantages are reflected in three aspects:
1. Accurate measurement of depth of consciousness:
A. Data Collection
1. Professional high-fidelity EMA EEG signal collection amplifier to ensure accurate data reading and strong anti-interference ability (similar products are professional high-fidelity amplifiers, so signal collection must be completed through high-precision click sheets, which increases the relative cost of consumables)
2. Click on continuous self-detection to ensure continuous high-quality EEG signals (other products use manual detection and cannot guarantee the accuracy of the signal at all times).
3. With dual-channel version, the brain point activities of the left and right hemispheres can be compared simultaneously.
B. Data Analysis
1. Automatically classify brain waves of intravenous and inhalation anesthesia.
2. Patients of different ages can be automatically classified, and the age is accurate to the day, ensuring the consistency of the results (other similar products are only divided into children and adult groups, but during childhood, brain waves develop gradually before the age of ten. If only one operation mode is used, patients of different ages will have different results, and the anesthesiologist needs to correct the results himself).
3. Perform data analysis on the original EEG signal (Similar products are analog digital signals, and the brain waves displayed on the screen are analog waves, which are not suitable for clinical EEG analysis. Narcotrend is an original EEG, and can perform EEG wave analysis on the EEG, which can be used as a relevant basis for diagnosing epileptic seizures and brain death).
4. Needle electrodes can be used without being restricted by surgical procedures, and can be sterilized and used repeatedly.
C. Result demonstration
In 2007, an authoritative American journal published a paper proving that the data is the most reliable among similar products. (1. Panousis P. Heller AR. Burghardt M. Bleyl JU. Koch T. The effects of electromyographic activity on the accuracy of the Narcotrend monitor compared with the BIS pectral Index during combined anaesthesial Anaesthesia 2007;62:868-874.)
2. Can be widely used in clinical practice:
1. Use ordinary heart electrodes, and the cost of use is negligible. (Similar products have higher consumable costs. Adopting European standards, low consumption, and ordinary heart electrodes can be used, which greatly saves the cost of use.)
2. There is no special requirement for the electrode position, and data can be read from any part of the brain. (The electrode position of similar products is fixed to the forehead and cannot be changed to other positions. The conventional position of the N electrode is also the forehead, but when the area is a surgical or disinfected area, the electrode can be attached to any position of the brain and can be used in all clinical general anesthesia surgeries).
3. Easy to operate, 10.4-inch color LCD touch screen. (Similar products are mostly small black and white screens, user feedback, operation and observation are easy).
3. Powerful data processing capabilities:
1. Powerful computing power, able to process raw EEG data, and respond quickly. (Similar products currently have a modular series, which can be inserted into a compatible multi-parameter monitor to monitor the depth of anesthesia. However, after modularization, the computing power is greatly reduced, the delay time is long, and the anti-interference ability is poor. At present, some hospitals are basically not satisfied with the use of them after purchasing them.)
2. Large information capacity, can save more than 1200 hours of patient data. (Similar products are less than 400 hours, and the storage medium is flash memory, data is easy to lose; hard disk storage, large capacity, easy to browse and search data, data can be imported into the computer, no upper limit to save.)
3. The data can be imported into the computer for statistical analysis. (The data can be imported into the computer or printed using a common printer, and stored in Excel format, which is convenient for customers to manage and count the data. The data volume is large, including all EEG spectrum data. Similar products can only use the built-in thermal printer to print simple data.)
Previous article:Detailed explanation of the steps of intelligent detection of ventilator
Next article:Design of portable intelligent self-blood glucose monitoring instrument
- Popular Resources
- Popular amplifiers
- Molex leverages SAP solutions to drive smart supply chain collaboration
- Pickering Launches New Future-Proof PXIe Single-Slot Controller for High-Performance Test and Measurement Applications
- CGD and Qorvo to jointly revolutionize motor control solutions
- Advanced gameplay, Harting takes your PCB board connection to a new level!
- Nidec Intelligent Motion is the first to launch an electric clutch ECU for two-wheeled vehicles
- Bosch and Tsinghua University renew cooperation agreement on artificial intelligence research to jointly promote the development of artificial intelligence in the industrial field
- GigaDevice unveils new MCU products, deeply unlocking industrial application scenarios with diversified products and solutions
- Advantech: Investing in Edge AI Innovation to Drive an Intelligent Future
- CGD and QORVO will revolutionize motor control solutions
- Innolux's intelligent steer-by-wire solution makes cars smarter and safer
- 8051 MCU - Parity Check
- How to efficiently balance the sensitivity of tactile sensing interfaces
- What should I do if the servo motor shakes? What causes the servo motor to shake quickly?
- 【Brushless Motor】Analysis of three-phase BLDC motor and sharing of two popular development boards
- Midea Industrial Technology's subsidiaries Clou Electronics and Hekang New Energy jointly appeared at the Munich Battery Energy Storage Exhibition and Solar Energy Exhibition
- Guoxin Sichen | Application of ferroelectric memory PB85RS2MC in power battery management, with a capacity of 2M
- Analysis of common faults of frequency converter
- In a head-on competition with Qualcomm, what kind of cockpit products has Intel come up with?
- Dalian Rongke's all-vanadium liquid flow battery energy storage equipment industrialization project has entered the sprint stage before production
- Allegro MicroSystems Introduces Advanced Magnetic and Inductive Position Sensing Solutions at Electronica 2024
- Car key in the left hand, liveness detection radar in the right hand, UWB is imperative for cars!
- After a decade of rapid development, domestic CIS has entered the market
- Aegis Dagger Battery + Thor EM-i Super Hybrid, Geely New Energy has thrown out two "king bombs"
- A brief discussion on functional safety - fault, error, and failure
- In the smart car 2.0 cycle, these core industry chains are facing major opportunities!
- The United States and Japan are developing new batteries. CATL faces challenges? How should China's new energy battery industry respond?
- Murata launches high-precision 6-axis inertial sensor for automobiles
- Ford patents pre-charge alarm to help save costs and respond to emergencies
- New real-time microcontroller system from Texas Instruments enables smarter processing in automotive and industrial applications
- Single Channel Sonar Receiver - Active Butterworth Filter
- It was found that the build script of micropython converts the .py file into a c file and then compiles it.
- [Zero-knowledge ESP8266 tutorial] Quick Start 5-Use buttons to control your lights
- Electrical Engineering Handbook: Power Electronics and Motor Drives (2nd Edition)
- Seeking advice on the flyback power supply not working problem
- IAR compilation information-size interpretation
- Online Circuit Simulator
- Badge for the 2020 Open Hardware Summit
- Automatically exit at irregular intervals during while
- ETU Configuration for CPU Card Programming