A complete solution to the design of soft switching power supply based on phase-shifted full-bridge circuit

Publisher:传邮万里Latest update time:2014-10-15 Source: 互联网 Reading articles on mobile phones Scan QR code
Read articles on your mobile phone anytime, anywhere

  The phase-shifted full-bridge converter can greatly reduce the switching voltage, current stress and spike interference of the power tube, reduce losses and increase the switching frequency. How to design a switching power supply based on PWM soft switching mode with UC3875 as the core? Please see the detailed explanation below.

  Main circuit analysis

  This soft switching power supply adopts a full-bridge converter structure and uses MOSFET as a switch tube with a parameter of 1000V/24A. It adopts phase-shifted ZVZCSPWM control, that is, the leading arm switch tube realizes ZVS and the lagging arm switch tube realizes ZCS. The circuit structure diagram is shown in Figure 1. VT1~VT4 are four MOSFET switch tubes of the full-bridge converter. VD1 and VD2 are the reverse-parallel ultra-fast recovery diodes of the leading arm switch tubes VT1 and VT2 respectively. C1 and C2 are high-frequency capacitors set to achieve ZVS of VTl and VT2 respectively. VD3 and VD4 are reverse current blocking diodes used to achieve ZCS of the lagging arm VT3 and VT4. Llk is the transformer leakage inductance, Cb is the blocking capacitor, T is the main transformer, and the secondary side is composed of a high-frequency rectifier circuit composed of VD5~VD8 and filter devices such as Lf, C3, and C4.

  

  Figure 1 1.2kw soft-switching DC power supply circuit diagram

  Its basic working principle is as follows:

  When the switch tubes VT1, VT4 or VT2, VT3 are turned on at the same time, the circuit works in the same way as the hard switch working mode of the full-bridge converter, and the primary side of the main transformer provides energy to the load. Through phase shift control, when VT1 is turned off, VT4 is not turned off immediately, but the phase shift angle is determined according to the output feedback signal, and VT4 is turned off after a certain period of time. Before turning off VT1, since VT1 is turned on, the voltage on its parallel capacitor C1 is equal to the conduction voltage drop of VT1, and its value is zero under ideal conditions. When VT1 is turned off, C1 starts to charge. Since the capacitor voltage cannot change suddenly, VT1 is turned off with zero voltage.

  Due to the transformer leakage inductance L1k and the secondary rectifier filter inductor, after VT1 is turned off, the primary current cannot change suddenly and continues to charge Cb. At the same time, C2 also discharges through the primary side. When the voltage of C2 drops to zero, VD2 is naturally turned on. At this time, VT2 is turned on with zero voltage.

  When C1 is fully charged and C2 is discharged, since VD2 is turned on, the voltage applied to the primary winding and leakage inductance of the transformer is the voltage across the blocking capacitor Cb, and the primary current begins to decrease, but Cb continues to be charged until the primary current is zero. At this time, due to the blocking effect of VD4, capacitor Cb cannot be discharged through VT2, VT4, and VD4, and the voltage across Cb remains unchanged. At this time, the current flowing through VT4 is zero, and turning off VT4 is zero current shutdown.

  After VT4 is turned off, VT3 is turned on after a preset dead time. Due to the existence of the transformer leakage inductance, the primary current cannot change suddenly, so VT3 is turned on with zero current.

  After VT2 and VT3 are turned on at the same time, the primary side provides energy to the load, and VT2 is turned off after a certain period of time. Due to the existence of C2, VT2 is turned off at zero voltage. As analyzed above, the primary current cannot change suddenly at this time. After C1 is discharged through VD3, VT3.Cb, VD1 is turned on naturally. At this time, turning on VT1 is zero voltage turning on. Due to the blocking of VD3, the primary current drops to zero, and VT3 is turned off. Then VT3 is turned off at zero current. After the pre-selected dead time delay, VT4 is turned on. Due to the leakage inductance of the transformer and the secondary filter inductance, the primary current cannot change suddenly, and VT4 is turned on at zero current.

  The ideal working waveform of the ZVZCS PWM full-bridge converter topology is shown in Figure 2, where Uab represents the voltage between points a and b in the main circuit diagram 3, ip is the primary current of the transformer T, Ucb is the voltage on the blocking capacitor Ub, and Urect is the voltage after secondary rectification.

  

  Figure 2 Ideal working waveform

  Design of the main control loop of UC3875

  In order to realize the ZVZCS soft switching of the main circuit switch tube, a PWM phase shift control circuit is designed for it using UC3875, as shown in Figure 3. Considering that the selected MOSFET has a relatively large power, the four output drive signals of the chip are power amplified, then isolated by high-frequency pulse transformers T1 and T2, and finally driven by the drive circuit to drive the MOSFET switch tube.

  

  Figure 3 PWM phase shift control circuit

  The entire control system uses the same 15V DC power supply for all power supplies. The switching frequency is set to 70kHz in the experiment, and the dead time is set to 1.5μs. A simple voltage control mode is used. The DC voltage output by the power supply forms a control signal after passing through the sampling circuit and the optoelectronic isolation circuit, and is input to the EA of the UC3875 error amplifier to control the output of the UC3875 error amplifier, thereby controlling the phase shift angle between the four outputs of the chip, so that the power supply can work stably. In the figure, R6 and C5 are connected between EA and E/AOUT to form PI control. In this design, the CS+ terminal is used as a fault protection circuit. When faults such as output overvoltage, output overcurrent, high-frequency transformer primary overcurrent, and switch tube overheating occur, the fault signal is converted into a voltage higher than 2.5V through a certain conversion circuit and connected to the CS+ terminal, so that the four output drive signals of UC3875 are all low level, and the circuit is protected.

  Figure 4 is the driving circuit of the switch tube. The isolation transformer is designed using the AP method, with a three-winding transformer with a transformation ratio of 1:1.3. The unipolar pulse output by UC3875 passes through the amplifier circuit, isolation circuit and drive circuit to form a +12V/-5V bipolar drive pulse to ensure the stable opening and closing of the switch tube.

  

  Figure 4 Switching tube drive circuit

  Simulation and Experimental Results Analysis

  PSpice is a powerful circuit analysis software. The simulation of ZVZCS soft switching power supply with switching frequency of 70kHz is carried out on PSpice9.1 platform.

  The main circuit structure of the experimental prototype adopts the circuit topology shown in Figure 1. The blocking diode adopts the ultra-fast recovery high-power diode RHRG30120, whose reverse recovery time is within 100ns, meeting the requirement of 70kHz switching frequency. The switch MOSFET adopts the IXFK24N100 switch tube of IXYS Company. This type of MOS tube has an ultra-fast recovery diode in reverse connection, and its reverse recovery time is about 250ns.

  Figure 5 is a waveform diagram of the driving voltage and tube voltage drop of the leading bridge arm switch tube. (a) is the simulation waveform and (b) is the experimental waveform. It can be seen that the leading arm switch tube fully realizes ZVS turn-on. When VT1 and VT2 are turned off, they rely on their own very small junction capacitance to achieve it. It can be seen from the figure that ZVS turn-off is basically achieved when they are turned off.

  

  Figure 5 Leading bridge arm switch tube drive voltage and tube voltage drop waveform

  

  Figure 6 Lag bridge arm switch driving voltage and current waveform

  Figure 6 is a diagram of the driving voltage and current waveforms of the lagging bridge arm switch tube, (a) is a simulation waveform, (b) is an experimental waveform;

  FIG7 is a diagram showing the voltage drop and current waveform of the lagging bridge arm switch tube, where (a) is the simulation waveform and (b) is the experimental waveform.

  

  Figure 7 Lagging bridge arm switches VT3 and VT4 achieve ZCS shutdown

  From Figures 6 and 7, it can be seen that the lagging arm switch tubes VT3 and VT4 have achieved ZCS shutdown very well, and the switch tube current is already zero when shutting down. Before the lagging arm switch tube is fully turned on, the switch tube current is also almost zero, basically achieving ZCS turn-on. Moreover, the lagging bridge arm switch tubes VT3 and VT4 can achieve ZCS switching in a wide load range.

  FIG8 is a waveform diagram of the voltage Uab between the midpoints of the two bridge arms, where (a) is a simulation waveform and (b) is an experimental waveform.

  

  Figure 8 Uab waveform

  FIG. 9 is a waveform of the voltage U on the blocking capacitor Cb, where (a) is a simulation waveform and (b) is an experimental waveform.

  

  Figure 9 Ucb waveform

  As can be seen from the figure above, due to the existence of Ucb, Uab is not a square wave. When Uab=0, the voltage Ucb on the blocking capacitor Cb gradually reduces the primary current ip to zero. Due to the blocking effect of the blocking diode, ip cannot flow in the reverse direction, thus realizing the ZCS switch of the lagging bridge arm.

  In summary, we can find that the advantage of using UC3875 as the core control device is that the structure is simple and the performance is reliable. In addition, all the switches in the main circuit realize soft switching, and some common errors in ZVS and ZCS modes are avoided. It can significantly reduce the loss of the switch tube during the switching process, thereby increasing the switching frequency, reducing the size of the power supply and reducing the weight.

Reference address:A complete solution to the design of soft switching power supply based on phase-shifted full-bridge circuit

Previous article:How to complete the reasonable design of switching power supply from conception to practice
Next article:Automotive Designs Require 65V Synchronous Step-Down Converter with Ultra-Low IQ

Latest Power Management Articles
Change More Related Popular Components

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

About Us Customer Service Contact Information Datasheet Sitemap LatestNews


Room 1530, 15th Floor, Building B, No.18 Zhongguancun Street, Haidian District, Beijing, Postal Code: 100190 China Telephone: 008610 8235 0740

Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号