The static protection access control system is a set of anti-static test access control management system based on computers and data. It is fully equipped with software and hardware, and can be connected by stand-alone, local connection, and TCP/IP communication. The access control system mainly manages the access rights of channels, that is, through the setting of channels to distinguish who can enter and who cannot enter, and there are multiple entry methods according to the card permission settings. The system can store data and can check all entry records and status records at any time. It is connected to the computer through the network cable interface to make the operation more intuitive and convenient. The system uses the most advanced non-contact IC (ID) card technology, uses radio frequency signals to exchange data, is contactless, has high confidentiality, high reliability, and has the function of using special cards for special people. It has the unparalleled advantages of magnetic cards, contact IC cards, and photoelectric cards.
The electrostatic protection access control system has five detection items and entry methods:
1. When the tester tests the anti-static shoes and anti-static wrist strap and they are both OK, the entrance door will open automatically and allow entry
2. When the tester tests the anti-static shoes and finds that they are OK, the door will open automatically and allow entry (the anti-static shoe test can distinguish between left and right feet)
3. When the tester tests the anti-static wrist strap and it is OK, the entrance door will open automatically and allow entry
4. When the tester encounters a VIP free test card, the entrance door automatically opens to allow entry
5. When the tester encounters an internal management personnel who does not need a test card, the entrance door will automatically open and allow entry
The five entry methods above correspond to five types of cards:
The first test is static shoes and wrist straps. Test shoes and wrist straps / Class 1 card
The second type only needs to test the static shoes/2 types of cards
The third type only needs to test the wrist strap/type 3 card
Fourth type of foreign VIP VIP/4 type card
The fifth type of internal management personnel management card/5 types of cards
Companies can set different test card permissions based on different testing requirements.
1. Basic components and operating principles of YT-A5 electrostatic protection access control system
A full-function access control system mainly includes the following components
1) An induction card reader with a microcontroller and memory function with more than 40,000 records, and connected to the management software on the computer
2) A tester with anti-static shoes and wrist straps
3) A set of system management software, including card reader management, personnel file management, automatic generation of reports and simple charts, automatic email sending to designated people or departments,
4) A card reader/writer for issuing cards, making it quick and convenient and saving time
5) A three-gate or other electronically driven door to monitor the entry of on-site testing employees.
6) An Ethernet switch for long distance TCP/IP communication
The working principle is that the tester sends an identification signal to the card machine when testing the employee. After being processed by the card swiping system, the card machine sends a control signal to the three gates for the employee to enter. (Swipe the card first - verify the card type and identity - perform static detection - upload the detection signal - the access control gives a pass or no entry instruction - computer data is saved)
2. Standard operating steps of YT-A5 electrostatic protection access control system
1. Prepare for the test: The tester must stand on the foot pedal (on) to prepare for the test item, and both feet must stand in the middle of the footprint
2. If you need to test the anti-static wrist strap, please insert it into the wrist strap test hole on the tester, or use a fish clip to directly clip it to the fish clip column next to the instrument.
3. To test the static electricity index of your feet, you must stand in the middle of the footprints and touch the test button with your fingers.
4. Bring your ID (IC) card close to the card reader, and the card reader will automatically read the information on the card.
5. Touch the test button with your finger and watch the LED on the tester display the test results, or look at the LCD screen on the card reader (the maximum test time is adjustable from 0 to 5 seconds. If it exceeds 5 seconds, you must swipe the card again and test again)
6. If the test is OK according to the settings, the system will open the access control unit to allow the tester to enter; if the test result is NO, check your wristband or shoes. The number of card swipes can be limited according to your company's requirements.
3. The role of using YT-A5 electrostatic protection access control system
In many places with anti-static protection, the testing of anti-static shoes and anti-static wrist straps is carried out by traditional manual entry or rough detection methods, which not only wastes time, but also causes missed tests due to human factors, causing potential risks to the quality of sensitive components. At the same time, the PBF-E8 anti-static access control system also realizes paperless recording function.
Common bad ways for employees to enter the factory for testing:
1. Directly enter the factory without testing
2. Fill in the "PASS" form without taking the test
3. Modify the record
4. Misattribution of test results when registering them
5. Fill out the form before testing
6. Fill in PASS even if the test fails
7. Fill in records on behalf of others
YT-A5 directly provides effective solutions to the above common shortcomings. Regardless of whether YT-A5 is equipped with a tripod gate, the mandatory settings and targetedness of the access control management system can eliminate the existence of human factors and make the test results more authentic and reliable. This system can count the test data of all employees with one click, including:
1) Record of employee entry test results, OK or not
2) The employee only swiped the card without testing the record
3) No record of employee swiping card
This system obtains the resistance of the human body to the ground by measuring the hands or feet of the human body, and uses LED display and buzzer alarm indication. It is an indispensable detection instrument for employee static electricity detection. This system uses a safe 12V voltage supply. The whole system completes paperless records and automatically generates employee attendance information reports in a safe, accurate, convenient, intuitive and real detection process, so that your company can achieve real time-saving and intuitive management of employees. Through the use of this system, it can also establish a good reputation and image for your company in the same industry.
4. Use multiple YT-A5s to form a simple structure
If you use multiple YT-A5s, you can connect them in series through a switch to form
A network that can be fully managed from a PC or operating system management software on a laptop
Access control software and hardware functions:
1) The system has access control function, which can detect the static electricity status and entry time of employees when they enter the workstation. There is no access control function when they leave, and they can pass freely.
2) The condition of the access control function is to complete the test of static shoes or wrist straps by swiping a card.
3) The software system has two detection modes: A. Mandatory detection mode B. Simple mode. In mode A, electrostatic detection must be performed. In mode B, only one entry is required and an OK record is recorded. No test card swipe is required 24 hours a day.
4) Employees can use the card type to automatically identify the items they need to test. The tester will automatically switch to the corresponding test items and display them at once. There is no need to flip the switch as before, which saves time and trouble.
5) The card swiping device uses advanced TCP/IP communication technology to enable one computer to manage multiple access control devices.
6) The human body comprehensive tester adopts the most effective touch test currently, cancels the previous key switch, and the test is more effective and convenient.
7) The card reader uses high-end color screen display technology, which is clearer and more beautiful, and displays internationally accepted symbols.
8) The management software can be set up to send emails to designated people or departments at regular intervals.
9) Of course, the simplest way is to install a small client software on any computer you want to use to query data, and then you can query the test data at any time, reducing the situation where you don’t have time to check emails for a long time.
10) The management system software can be set to collect test data at a fixed time every day, or it can collect data in real time
11) The management software can import the data of the human resources department with one click, saving time for complicated operations
The management operation software can be summarized with one click. The software directly filters out 1. Those who passed the test 2. Those who failed the test 3. Those who only swiped the card without detecting static electricity 4. Those who only detected static electricity without swiping the card 5. Those who entered with VIP cards 6. Those who entered as management personnel. The accurate table shows the number of people.
Previous article:Discussion on the design of parking fee collection system based on NFC+3G technology
Next article:Five major issues that have a significant impact on the development of RFID technology
- Popular Resources
- Popular amplifiers
- Mir T527 series core board, high-performance vehicle video surveillance, departmental standard all-in-one solution
- Akamai Expands Control Over Media Platforms with New Video Workflow Capabilities
- Tsinghua Unigroup launches the world's first open architecture security chip E450R, which has obtained the National Security Level 2 Certification
- Pickering exhibits a variety of modular signal switches and simulation solutions at the Defense Electronics Show
- Parker Hannifin Launches Service Master COMPACT Measuring Device for Field Monitoring and Diagnostics
- Connection and distance: A new trend in security cameras - Wi-Fi HaLow brings longer transmission distance and lower power consumption
- Smartway made a strong appearance at the 2023 CPSE Expo with a number of blockbuster products
- Dual-wheel drive, Intellifusion launches 12TOPS edge vision SoC
- Toyota receives Japanese administrative guidance due to information leakage case involving 2.41 million pieces of user data
- LED chemical incompatibility test to see which chemicals LEDs can be used with
- Application of ARM9 hardware coprocessor on WinCE embedded motherboard
- What are the key points for selecting rotor flowmeter?
- LM317 high power charger circuit
- A brief analysis of Embest's application and development of embedded medical devices
- Single-phase RC protection circuit
- stm32 PVD programmable voltage monitor
- Introduction and measurement of edge trigger and level trigger of 51 single chip microcomputer
- Improved design of Linux system software shell protection technology
- What to do if the ABB robot protection device stops
- Sn-doped CuO nanostructure-based ethanol gas sensor for real-time drunk driving detection in vehicles
- Design considerations for automotive battery wiring harness
- Do you know all the various motors commonly used in automotive electronics?
- What are the functions of the Internet of Vehicles? What are the uses and benefits of the Internet of Vehicles?
- Power Inverter - A critical safety system for electric vehicles
- Analysis of the information security mechanism of AUTOSAR, the automotive embedded software framework
- Brief Analysis of Automotive Ethernet Test Content and Test Methods
- How haptic technology can enhance driving safety
- Let’s talk about the “Three Musketeers” of radar in autonomous driving
- Why software-defined vehicles transform cars from tools into living spaces
- TI Wireless Connectivity Technology Selection Guide
- Adding SDCard functionality to ESP32-S3 with MicroPython
- Show off the development boards I bought in recent months
- The flavor of the New Year is the “poor flavor” of backward productivity
- ZigBee Power Consumption Calculation
- When burning the program, you mistakenly select "cold start" and the program can only be downloaded when P3.2/P3.3 is 0/0. Solution
- Buy OBD source code
- Problem of True RMS Conversion of Sine Wave
- stm8s serial communication cannot detect the port
- Detailed capture of msp430g2553