Reasonable usage methods can not only ensure the normal use of the instrument and reduce malfunctions, but also ensure the accuracy of the results and extend its service life. So how should the Skyray Instrument RoHS tester be used reasonably?
1. Cleaning of the surface and shell. The instrument can be cleaned with a slightly damp cloth. Do not use alkaline or acidic detergents. Use neutral detergents instead.
2. It is strictly forbidden for non-specially designated personnel to operate the instrument. The operation must be carried out according to the operating steps. Any wrong operation will affect the test results and service life of the instrument;
3. Reasonable working environment of the equipment. It is required to be installed in a place without electromagnetic interference such as motors, vibration, electromagnetic, high voltage or high-frequency welding machines, otherwise it will interfere with the spectrum of the equipment or cause the equipment to malfunction;
4. Cleaning of the interior and detector. During the cleaning process, be careful not to drop foreign objects into the test window. The test window should be kept clean. Do not use hard objects to touch the test window to prevent damage to the detector window and X-ray tube window. (Damage to the detector window and X-ray tube window will not be covered by warranty, and replacement is expensive. Therefore, be careful when cleaning and using it);
5. When the instrument is in operation, do not open the protective cover of the instrument or point the test instrument at the human body;
6. Do not place tea cups, heavy objects or other items not related to the test on the instrument to avoid contamination or damage to the instrument;
7. The instrument must be calibrated every time it is turned on and every 4 hours of continuous operation;
8. This instrument will generate ionizing radiation. Make sure not to point the instrument at people during testing.
9. Do not point the RoHS tester at the air for testing; do not hold the sample in your hands for testing.
Precautions for using RoHS tester
1. The instrument will generate ionizing radiation. Make sure not to point the instrument at people during testing; do not point the instrument at the air for testing; do not hold the sample in your hands for testing;
2. When the ROHS tester is in operation, do not open the protective cover of the instrument or point the tester at the human body;
3. The instrument must be calibrated every time it is turned on and every 4 hours of continuous operation;
4. It is strictly forbidden for non-specially designated personnel to operate the instrument. The operation must be carried out according to the operating steps. Any incorrect operation will affect the test results and service life of the instrument.
5. After the test is completed, click the "Set" X-ray tube button, click the "Turn on high voltage power supply" button in the dialog box that appears, and then click OK. You can proceed to the next step only when the tube pressure and tube flow are OK. Click the "Close button" in the upper right corner of the operation interface. After the software is closed, you can close the hardware.
Previous article:Introduction to Mask Filter Tester
Next article:Application of wire harness tester in multi-core cable continuity and insulation test scheme
- Popular Resources
- Popular amplifiers
- Real-time driver monitoring system via modal and viewpoint analysis
- Semantic Segmentation for Autonomous Driving: Model Evaluation, Dataset Generation, Viewpoint Comparison, and Real-time Performance
- Monocular semantic map localization for autonomous vehicles
- Introduction to Deep Learning 2: Homemade Framework (Yasuki Saito)
- Keysight Technologies Helps Samsung Electronics Successfully Validate FiRa® 2.0 Safe Distance Measurement Test Case
- From probes to power supplies, Tektronix is leading the way in comprehensive innovation in power electronics testing
- Seizing the Opportunities in the Chinese Application Market: NI's Challenges and Answers
- Tektronix Launches Breakthrough Power Measurement Tools to Accelerate Innovation as Global Electrification Accelerates
- Not all oscilloscopes are created equal: Why ADCs and low noise floor matter
- Enable TekHSI high-speed interface function to accelerate the remote transmission of waveform data
- How to measure the quality of soft start thyristor
- How to use a multimeter to judge whether a soft starter is good or bad
- What are the advantages and disadvantages of non-contact temperature sensors?
- LED chemical incompatibility test to see which chemicals LEDs can be used with
- Application of ARM9 hardware coprocessor on WinCE embedded motherboard
- What are the key points for selecting rotor flowmeter?
- LM317 high power charger circuit
- A brief analysis of Embest's application and development of embedded medical devices
- Single-phase RC protection circuit
- stm32 PVD programmable voltage monitor
- Introduction and measurement of edge trigger and level trigger of 51 single chip microcomputer
- Improved design of Linux system software shell protection technology
- What to do if the ABB robot protection device stops
- P22-009_Butterfly E3106 Cord Board Solution
- Keysight Technologies Helps Samsung Electronics Successfully Validate FiRa® 2.0 Safe Distance Measurement Test Case
- Innovation is not limited to Meizhi, Welling will appear at the 2024 China Home Appliance Technology Conference
- Innovation is not limited to Meizhi, Welling will appear at the 2024 China Home Appliance Technology Conference
- Huawei's Strategic Department Director Gai Gang: The cumulative installed base of open source Euler operating system exceeds 10 million sets
- Download from the Internet--ARM Getting Started Notes
- Learn ARM development(22)
- Learn ARM development(21)
- Learn ARM development(20)
- Learn ARM development(19)
- Start with a Routine
- Share a reference book on servo motor drive
- Is FPGA a big deal in the field of artificial intelligence?
- 【GD32F310G-START】Voltage meter
- C language algorithm to calculate the age of beautiful women
- LOTO virtual oscilloscope about trigger sensitivity function
- [ST60 short-distance test] Part 2: Communication rate test
- PT4115 cannot be completely shut down
- STM32 Linux development board recommendation | PHYTEC development board: Help you reduce development risks and improve product stability
- FAQ|Beineng International's new glass breakage detection solution