Structural characteristics and technical parameters of magnetic flap level gauge

Publisher:trendsetter9Latest update time:2020-01-03 Source: elecfans Reading articles on mobile phones Scan QR code
Read articles on your mobile phone anytime, anywhere

Structural features of magnetic flap level gauge:


The basic type of magnetic flap level gauge is based on the principle of buoyancy. The float moves up and down in the measuring tube as the liquid level rises and falls. The *magnetic steel in the float drives the red and white flaps to flip 180 degrees through magnetic coupling. When the liquid level rises, the flap turns from white to red, and when it drops, it turns from red to white, thereby realizing the indication of the liquid level.


The upper and lower limit switch output uses a magnetic float to move with the liquid level, causing the reed switch installed at the set position of the magnetic flap level gauge riser to actuate, achieving ON-OFF control or alarm.


The transmitter is installed on the magnetic flap level gauge. The transmitter consists of two parts: sensor and converter. It moves the magnetic float up and down, and the measuring parts in the conduit move in sequence through magnetic coupling, obtains the resistance signal change, and converts it into a standard current signal output of 0~10mA or 4~20mA, so as to connect with the digital display instrument or computer to realize remote display.

Structural characteristics and technical parameters of magnetic flap level gauge

Magnetic flap level gauge technical parameters:

Measuring range: 0.3m~6m (selected according to the actual measuring range)

Connection method: threaded connection, flange connection (side installation, top installation optional)

Body material: SUS304, 316L, PP, PVC, polytetrafluoro, etc.

Signal output: 4~20mA, upper and lower limit alarm (normally open or normally closed)

Working pressure: ≤6.3MPa

Distance measurement accuracy: ≤±10mm

Medium temperature: -20℃~450℃

Medium density: ≥0.45g/cm3

Medium viscosity: ≤0.15pa·s

Protection level: IP65

Explosion-proof grade: ExdⅡBT4

New model: WUHZ661

Reference address:Structural characteristics and technical parameters of magnetic flap level gauge

Previous article:Classification and selection of steam flow meter
Next article:The correct selection method of vortex flowmeter

Latest Test Measurement Articles
Change More Related Popular Components

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

About Us Customer Service Contact Information Datasheet Sitemap LatestNews


Room 1530, 15th Floor, Building B, No.18 Zhongguancun Street, Haidian District, Beijing, Postal Code: 100190 China Telephone: 008610 8235 0740

Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号