It is suitable for medium level measurement of various containers; it has bright red and green display, high display brightness, long visible distance, clear scale and large display angle. It is a replacement product of the old level meter and is widely used in liquid level measurement and control of various towers, tanks and boiler equipment in electric power, metallurgy, petroleum, chemical industry, environmental protection, shipbuilding and other industries.
The liquid level gauge works based on the principles of buoyancy and magnetic coupling. When the liquid level in the measured container rises or falls, the float in the main pipe of the liquid level gauge also rises or falls. The magnet in the float is transmitted to the on-site indicator through magnetic coupling, driving the red and white turning column to rotate 180°. When the liquid level rises, the turning column turns from white to red, and when the liquid level drops, the turning column turns from red to white. The red and white boundary position of the indicator is the actual height of the medium level in the container, thereby realizing the indication of the liquid level.
Scope of application
The corrosion-resistant magnetic flap (column ball) level gauge adopts a stainless steel body lined with polypropylene PP technology, which has high structural strength and corrosion resistance, and can be used for acidic and alkaline liquids such as hydrochloric acid and many organic solvents (especially active solvents). However, it is not suitable for the measurement of concentrated nitric acid, ammonia acid mixtures, chlorinated solvents, aliphatic, aromatic hydrogen and other medium liquids.
Suitable for level measurement of corrosive media. In addition to on-site indication, it can also be equipped with remote transmitters and alarms (control switches), with complete detection functions. The indication is novel, the readings are intuitive and eye-catching, and the direction of the indicator can be changed according to user needs. The measuring range is large and is not limited by the height of the storage tank. The indicating mechanism is completely isolated from the measured medium, so it has good sealing, high reliability and safe use. The structure is simple, easy to install and low maintenance cost.
Technical Parameters
Measuring range: 300~8000mm. For level gauges with center distance exceeding 8000mm or long-distance transmission conditions that do not allow exceeding the length, segmented manufacturing can be adopted.
Working pressure: ≤6.0 MPa
Working temperature: -20~80℃
Accuracy: ±10mm
Medium density: 0.38~1.2g/cm3
Environmental vibration: frequency ≤ 25Hz, amplitude ≤ 0.5mm
Following speed: ≤0.08m/s
Medium viscosity: ≤0.4Pa.s. For medium with high viscosity or medium that is easy to crystallize when measuring at low temperature, a heating jacket type liquid level meter can be selected.
Process connection: Bypass side mounting flange: DN25, PN1.0 convex
Flange standard: HG20592~20635-97. Please specify other flange standards.
Material: Bypass pipe: PP
Float: PP
Optional:
use:
1. To prevent the float from moving up and down and causing damage during long-distance transportation or transport, the calibration magnet provided with the level meter is used to absorb the magnetic float on the outside of the main pipe (with a color mark). Therefore, after receiving the product or installing it, please remove the calibration magnet so that the float can move up and down with the liquid level. If the color of the magnetic flip column is inconsistent before use, the calibration magnet can be used to absorb it and the meter can work normally.
2. After the level gauge is installed, it needs to be calibrated with a magnetic steel, and the magnetic column should be guided once so that the display below zero is red and the display above zero is white.
3. When the liquid level meter is put into long-distance operation, the upper liquid pipe valve should be opened first, and then the lower liquid pipe valve should be opened slowly to allow the liquid medium to enter the main pipe smoothly to prevent the liquid medium from rising rapidly with the float, causing the magnetic column to fail to flip or flip disorderly (if this happens, it can be recalibrated with magnetic steel).
maintain
1. Solid impurities and magnetic impurities should not enter the cylinder of the level gauge to avoid blocking the float and reducing the buoyancy.
2. Depending on the medium conditions, the main pipe can be cleaned regularly to remove the impurities deposited in the pipe.
3. When cleaning the liquid or replacing the float, open the drain flange. When installing the magnetic float, pay attention to the heavy end with the magnet facing upwards and do not install it upside down!
Previous article:How to measure capacitance with a multimeter_Measure capacitance with a pointer multimeter_Precautions for measuring capacitance with a multimeter
Next article:How to measure capacitance with a multimeter_Methods for testing capacitance with a multimeter
- Popular Resources
- Popular amplifiers
- Seizing the Opportunities in the Chinese Application Market: NI's Challenges and Answers
- Tektronix Launches Breakthrough Power Measurement Tools to Accelerate Innovation as Global Electrification Accelerates
- Not all oscilloscopes are created equal: Why ADCs and low noise floor matter
- Enable TekHSI high-speed interface function to accelerate the remote transmission of waveform data
- How to measure the quality of soft start thyristor
- How to use a multimeter to judge whether a soft starter is good or bad
- What are the advantages and disadvantages of non-contact temperature sensors?
- In what situations are non-contact temperature sensors widely used?
- How non-contact temperature sensors measure internal temperature
- LED chemical incompatibility test to see which chemicals LEDs can be used with
- Application of ARM9 hardware coprocessor on WinCE embedded motherboard
- What are the key points for selecting rotor flowmeter?
- LM317 high power charger circuit
- A brief analysis of Embest's application and development of embedded medical devices
- Single-phase RC protection circuit
- stm32 PVD programmable voltage monitor
- Introduction and measurement of edge trigger and level trigger of 51 single chip microcomputer
- Improved design of Linux system software shell protection technology
- What to do if the ABB robot protection device stops
- CGD and Qorvo to jointly revolutionize motor control solutions
- CGD and Qorvo to jointly revolutionize motor control solutions
- Keysight Technologies FieldFox handheld analyzer with VDI spread spectrum module to achieve millimeter wave analysis function
- Infineon's PASCO2V15 XENSIV PAS CO2 5V Sensor Now Available at Mouser for Accurate CO2 Level Measurement
- Advanced gameplay, Harting takes your PCB board connection to a new level!
- Advanced gameplay, Harting takes your PCB board connection to a new level!
- A new chapter in Great Wall Motors R&D: solid-state battery technology leads the future
- Naxin Micro provides full-scenario GaN driver IC solutions
- Interpreting Huawei’s new solid-state battery patent, will it challenge CATL in 2030?
- Are pure electric/plug-in hybrid vehicles going crazy? A Chinese company has launched the world's first -40℃ dischargeable hybrid battery that is not afraid of cold
- MSP430 clock setting and application
- [Shanghai Hangxin ACM32F070 development board + touch function evaluation board] Development environment construction and initial experience
- 520, Give Tang Monk a Wife
- [Evaluation of domestic FPGA Gaoyun GW1N series development board]——(1) Development environment
- Talk about differential signal
- DSP code optimization instructions in CCS
- Help, what kind of lights are these? I see them for the first time.
- 【Repair】Fire emergency light fault inspection and repair
- EEWORLD University - Multi-Camera System with DS90UB960 Deserializer Hub and TDA SoC: Training Series
- Why is the maximum angle read by the resolver chip AD2S1210 only 180°?