EEWORLDEEWORLDEEWORLD

Part Number

Search

GLM75C

Description
Linear and switching power supply 75w +5.1/+12/-12/12v
Categorysemiconductor    Power management   
File Size271KB,2 Pages
ManufacturerAll Sensors
Download Datasheet Parametric View All

GLM75C Online Shopping

Suppliers Part Number Price MOQ In stock  
GLM75C - - View Buy Now

GLM75C Overview

Linear and switching power supply 75w +5.1/+12/-12/12v

GLM75C Parametric

Parameter NameAttribute value
MakerAll Sensors
Product CategoryLinear vs. Switching Power Supplies
RoHSno
productSwitching
Commercial/MedicalMedical
Output power rating40 W
Input voltage90 VAC to 264 VAC
Number of outputs4
Output voltage (channel 1)5 V
Output current (channel 1)8 A
Output voltage (channel 2)12 V
Output current (channel 2)2.5 A
Output voltage (channel 3)- 15 V
Output current (channel 3)1 A
Installation styleChassis
size177.8 mm L x 107.95 mm W x 33.02 mm H
open frame/closedOpen Frame
Output typeMultiple Outpu
series connectionGLM
GLOBAL PERFORMANCE SWITCHERS
GLC75 Commercial/GLM75 Medical
75 Watt Multiple Output Global Performance Switchers
FEATURES:
• Cost-effective multiple output power source
• Universal input 90-264 Vac
• 7.00”x 4.25”x 1.30” (Meets 1U height)
• 2-year warranty
• Conducted EMI exceeds FCC Class B and CISPR 22
Class B (Commercial models) and CISPR 11 Class B
(Medical models)
• Complies with EN61000-3-2 Class A
• Also available in single output versions
• Commercial UL1950 3rd Edition, CSA22.2 No. 950 and
EN60950-1 approvals
• Medical Approved to UL2601-1,
CSA22.2 No. 601.1-M90, and IEC/EN60601-1
• RoHS Compliant Model Available (G suffix)
SPECIFICATIONS
Ac Input
90-264 Vac, 47-63 Hz single phase.
Input Current
Maximum input current at 120 Vac, 60 Hz with full rated output load not to
exceed 2.3 A.
Output Power
Normal continuous output power is 75 W for unrestricted natural convection
cooling or 110 W with 26 cfm airflow. During peak load conditions output
regulation may exceed total regulation and noise limits.
Output Regulation
Measured by ±40% load change from 60% rated load with all other outputs
at 60% rated load and input voltage change from minimum to maximum rat-
ings. Output #1 requires 1A minimum load for proper regulation of other
outputs. Initial set tolerance is measured with all outputs at 60% of full rated
load. Output #2 requires 0.5A minimum load for proper regulation.
Overload Protection
Factory set to begin power limiting at approximately 120 W. Fully protected
against short circuit and output overload. Short circuit protection is cycling
type power limit.
Output Noise
0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential mode. Measured with
noise probe directly across output terminals of the power supply.
Transient Response
Main Output: 500μSec typical response time for return to within 0.5% of final
value for a 50% load step change, ∆i/∆t<0.2A/μSec. Maximum voltage devia-
tion is 3.5%.
Overvoltage Protection
Built in on V1 with firing point set per table. OVP firing reduces output #1 and
#2 to less than 50% of nominal voltage in 50 ms.
Voltage Adjust
Factory set on standard unit; however, optional potentiometer (“-V” suffix)
adjusts voltage from 4.7 V to OVP point (6.2 V nominal) on the +5 V output.
Note: Output #1 must not be more than 1% below nominal to achieve full
output voltage range on Output #2. Output regulation limits in some models
may be exceeded when the main output is adjusted beyond +1% of nominal
voltage. High voltage settings may degrade the reliability of the unit due to
excessive power dissipation in some outputs.
Efficiency
68% -78% depending on model and load distribution.
Input Protection
Internal ac fuse provided on all units. Designed to blow only if a catastrophic
failure occurs in the unit.
Inrush Current
Inrush limited by internal thermistors. Inrush at 240 Vac, averaged over the first ac
half-cycle under cold start conditions will not exceed 37 A.
Hold Up Time
20 ms minimum from loss of ac input power at full load, nominal line (120 Vac).
Temperature Coefficient
0.03%/°C typical on all outputs.
Power Fail
A standard TTL or CMOS compatible output goes low (< 0.5 V) 5ms before output
voltage drops more than 4% below nominal voltage upon loss of ac power. Signal
is factory set to trip on 84 to 94 Vac brown-out depending upon incoming line
impedance and distortion. Other settings are available through adjustment of
built-in potentiometer (consult factory for assistance). Output will stay low for 20
ms minimum.
EMI/EMC Compliance
All models include built-in EMI filtering to meet the following emissions requirements:
EMI SPECIFICATIONS
Conducted Emissions GLC75
Conducted Emissions GLM75
Static Discharge
RF Field Susceptibility
Fast Transients/Bursts
Surge Susceptibility
Line Frequency Harmonics
COMPLIANCE LEVEL
EN55022 Class B; FCC Class B
EN55011 Class B: FCC Class B
EN61000-4-2, 6 kV contact, 8 kV air
EN61000-4-3, 3 V/meter
EN61000-4-4, 2 kV, 5 kHz
EN61000-4-5, 1 kV diff., 2 kV com.
EN61000-3-2 Class A
Commercial Safety
All GLC models are approved to UL1950 3rd Edition, CSA22.2 No. 950, and
EN60950-1.
Medical Leakage Current
70 μA 264 V @ 50 Hz (normal conditions).
Medical Safety
GLM models are approved to UL2601-1, CSA22.2 No. 601.1M90, IEC/EN60601-1. CB
Report available.
All specifications are typical at nominal input, full load at 25
O
C unless otherwise stated
TriQuint and RFMD have merged to form Qorvo, a new global leader in RF solutions.
This content is originally created by btty038, a user of EEWORLD forum. If you want to reprint or use it for commercial purposes, you must obtain the author’s consent and indicate the source....
btty038 RF/Wirelessly
Blood oxygen saturation is detected by receiving the energy ratio of infrared light and red light, and then it can be calculated by adding an algorithm. Then the heart rate...
Blood oxygen saturation is detected by receiving the energy ratio of infrared light and red light, and then it can be calculated by adding an algorithm. So how is heart rate detection achieved? What a...
QWE4562009 Discrete Device
[Fudan Micro FM33LG0 Series Development Board Review] Compile and Download
[i=s]This post was last edited by Beifang on 2021-11-26 10:35[/i][index][#1]1. GPIO project code analysis[#2]2. Project compilation 3. Download thecode1. GPIO project code analysis No matter east, wes...
北方 Domestic Chip Exchange
Summary of DSP28335 using FIFO serial port interrupt
[size=4]1. Serial communication and parallel communication [/size] [size=4] DSP controllers exchange information and communicate with external devices. There are two main communication methods: 1. Ser...
Aguilera DSP and ARM Processors
CC1352P Dual-Band Multi-Protocol Wireless Solution
The CC1352P device is a multiprotocol, multiband (Sub-1 GHz and 2.4 GHz) wireless MCU targeting Wireless M-Bus, IEEE 802.15.4g, Smart Objects with IPv6 (6LoWPAN), Thread, Zigbee, KNX RF, Wi-SUN, Bluet...
Jacktang Wireless Connectivity
Award-winning live broadcast: ST's IO-Link-based environmental monitoring and predictive maintenance solutions
ST Award-winning live broadcast: Environmental monitoring and predictive maintenance solutions based on IO-Link. You are invited to watch at 10:00 am on July 22 (Thursday)!Click here to registerLive T...
EEWORLD社区 Industrial Control Electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号