Standard termination finish is 100% matte Tin (Sn).
DIMENSIONS
Unit: inch (mm)
SIZE
L
L
0.063 ± 0.0078
(1.60 ± 0.20)
0.079 ± 0.0078
(2.00 ± 0.20)
0.130 ± 0.012
(3.30 ± 0.30)
0.130 ± 0.0158
(3.30 ± 0.40)
0.177 ± 0.0158
(4.50 ± 0.40)
0.177 ± 0.0158
(4.50 ± 0.40)
0.177 ± 0.0158
(4.50 ± 0.40)
0.225 ± 0.0158
(5.70 ± 0.40)
0.225 ± 0.0158
(5.70 ± 0.40)
W
0.0315 ± 0.0078
(0.80 ± 0.20)
0.05 ± 0.0078
(1.25 ± 0.20)
0.063 ± 0.0078
(1.60 ± 0.20)
0.0985 ± 0.012
(2.50 ± 0.30)
0.080 ± 0.0098
(2.03 ± 0.25)
0.126 ± 0.0158
(3.20 ± 0.40)
0.252 ± 0.0158
(6.4 0 ± 0.40)
0.197 ± 0.0158
(5.00 ± 0.40)
0.248 ± 0.0158
(6.30 ± 0.40)
T
See Specific Value
See Specific Value
See Specific Value
See Specific Value
See Specific Value
See Specific Value
See Specific Value
See Specific Value
See Specific Value
E/B
0.0158 ± 0.006
(0.40 ± 0.15)
0.020 ± 0.0078
(0.50 ± 0.20)
0.0236 ± 0.0078
(0.60 ± 0.20)
0.0295 ± 0.0138
(0.75 ± 0.35)
0.0295 ± 0.0138
(0.75 ± 0.35)
0.0295 ± 0.0138
(0.75 ± 0.35)
0.0295 ± 0.0138
(0.75 ± 0.35)
0.0335 ± 0.0138
(0.85 ± 0.35)
0.0335 ± 0.0138
(0.85 ± 0.35)
0603
0805
W
1206
1210
1808
C
C
1812
T
1825
2220
2225
C
C
Email:
sales@venkel.com
|
Phone:
512.794.0081
|
Toll Free:
800.950.8365
|
Web:
www.venkel.com
Rev: 01/2021-A
1
HVC
C0G (NP0)
HIGH VOLTAGE CERAMIC CAPACITORS
ELECTRICAL SPECIFICATION
Typical Capacitance Change vs. Temperature
15%
10%
SERIES
5%
0%
-5%
-10%
-15%
-55˚C
-25˚C
0˚C
25˚C
50˚C
75˚C
100˚C
125˚C
Operating Temperature Range:
-55°C to +125°C
Temperature Coefficient:
0 ±30PPM/°C
Temperature Voltage Coefficient:
0 ±30PPM/°C
Insulation Resistance:
>100
Ω-F
or 10 GΩ, whichever is less at 25°C, WDCV.
(The IR at 125°C is 10% of the value at 25°C)
Withstanding Voltage:
See below
Capacitance Tolerance:
C, D, F, G, J, K
Dielectric Strength is equal to 1.5 times rated voltage (WVDC) for 500 volt capacitors and 1.2 times (WVDC) for 1,000 through
5,000 volt capacitors.
Circuit applications in excess of 1,000 volts may require a surface coating to prevent external arcing.
X7R
Typical Capacitance Change vs. Temperature
15%
10%
5%
0%
-5%
-10%
-15%
-55˚C
-25˚C
0˚C
25˚C
50˚C
75˚C
100˚C
125˚C
Operating Temperature Range:
-55°C to +125°C
Temperature Coefficient:
0 ±15%∆°C MAX.
Temperature Voltage Coefficient:
X7R not applicable
Insulation Resistance:
>100 ohms F or 10 G ohms, whichever
is less at 25°C, WDCV.
(The IR at 125°C is 10% of the value at 25°C)
Withstanding Voltage:
See below
D.F. Specification:
≥50V, ≤2.5%
Capacitance Tolerance:
J,K,M,N
TEST PARAMETERS
Test parameters for Multilayer Ceramic Capacitors - X7R:
Test parameters for Multilayer Ceramic Capacitors - C0G (NP0):
1KHz ± 50Hz at 1.0 ± 0.2 Vrms, 25°C
1MHz ± 50KHz at 1.0 ± 0.2 Vrms
≤
1000pF, 25°C
1KHz ± 50Hz at 1.0 ± 0.2 Vrms > 1000pF, 25°C
Note:
To ensure proper capacitance readings, the voltage level must be held constant. The HP4284 and Agilent E4980
has a “ALC” (Automatic Level Control) function and should be switched to the “ON” position for accurate
capacitance readings.
Email:
sales@venkel.com
|
Phone:
512.794.0081
|
Toll Free:
800.950.8365
|
Web:
www.venkel.com
Rev: 01/2021-A
2
HVC
HIGH VOLTAGE CERAMIC CAPACITORS
VOLTAGE AND CAPACITANCE RANGE
w
SERIES
L
E/B
C0G (NP0) DIELECTRIC
SIZE
L
W
T (max)
E/B
VDCW (MAX)
0R5
1R0
1R2
1R5
1R8
2R0
2R2
2R7
3R3
3R9
5R0
8R2
100
120
150
180
220
270
330
390
470
560
680
820
101
121
151
181
221
271
331
391
471
561
681
821
102
122
152
182
222
272
332
392
472
562
682
822
103
123
153
183
223
273
< ------------------------------------------------------------------------------------------------ CAPACITANCE VALUE ----------------------------------------------------------------------------------------------->
Values that are typically available.
All measurements in inches (mm)
T
0603
0.063
±
0.0078
(1.60
±
0.20)
0.0315
±
0.0078
(0.8
±
0.20)
0.0394
(1.0)
0.0158 ± 0.006
(0.40 ± 0.15)
200V / 250V
0805
0.083 ± 0.0078
(2.10 ± 0.20)
0.05 ± 0.0078
(1.25 ± 0.20)
0.057
(1.45)
0.020 ± 0.0078
(0.50 ± 0.20)
200V /
250V
500V
600V /
630V
200V /
250V
500V
1206
0.130 ± 0.012
(3.30 ± 0.30)
0.063 ± 0.0078
(1.60 ± 0.20)
0.075
(1.90)
0.0236 ± 0.0078
(0.60 ± 0.20)
600V /
630V
1KV
2KV
3KV
200V /
250V
1210
0.130 ± 0.0158
(3.30 ± 0.40)
0.0985 ± 0.012
(2.50 ± 0.30)
0.110
(2.80)
0.0295 ± 0.0138
(0.75 ± 0.35)
500V
600V /
630V
1KV
0.5pF
1.0pF
1.2pF
1.5pF
1.8pF
2.0pF
2.2pF
2.7pF
3.3pF
3.9pF
5.0pF
8.2pF
10pF
12pF
15pF
18pF
22pF
27pF
33pF
39pF
47pF
56pF
68pF
82pF
100pF
120pF
150pF
180pF
220pF
270pF
330pF
390pF
470pF
560pF
680pF
820pF
1000pF
1200pF
1500pF
1800pF
2200pF
2700pF
3300pF
3900pF
4700pF
5600pF
6800pF
8200pF
0.01uF
0.012uF
0.015uF
0.018uF
0.022uF
0.027uF
Note: Additional
values may be available. Please contact us for more information. Due to demand and raw material fluctuations, specific values may not be available.
< ------------------------------------------------------------------------------------------------ CAPACITANCE VALUE ----------------------------------------------------------------------------------------------->
Values that are typically available.
All measurements in inches (mm)
T
1808
0.177 ± 0.0158
(4.50 ± 0.40)
0.080 ± 0.0098
(2.03 ± 0.25)
0.90
(2.28)
0.0295 ± 0.0138
(0.75 ± 0.35)
500V
600V /
630V
1KV
2KV
3KV
5KV
200V /
250V
500V
1812
0.177 ± 0.0158
(4.50 ± 0.40)
0.126 ± 0.0158
(3.20 ± 0.40)
0.118
(3.0)
0.0295 ± 0.0138
(0.75 ± 0.35)
600V /
630V
1KV
2KV
3KV
200V /
250V
1825
0.177 ± 0.0158
(4.50 ± 0.40)
0.252 ± 0.0158
(6.40 ± 0.40)
0.128
(3.25)
0.0295 ± 0.0138
(0.75 ± 0.35)
500V
600V /
630V
1KV
0.5pF
1.0pF
1.2pF
1.5pF
1.8pF
2.0pF
2.2pF
2.7pF
3.3pF
3.9pF
5.0pF
8.2pF
10pF
12pF
15pF
18pF
22pF
27pF
33pF
39pF
47pF
56pF
68pF
82pF
100pF
120pF
150pF
180pF
220pF
270pF
330pF
390pF
470pF
560pF
680pF
820pF
1000pF
1200pF
1500pF
1800pF
2200pF
2700pF
3300pF
3900pF
4700pF
5600pF
6800pF
8200pF
0.01uF
0.012uF
0.015uF
0.018uF
0.022uF
0.027uF
Note: Additional
values may be available. Please contact us for more information. Due to demand and raw material fluctuations, specific values may not be available.
At present, mobile phone and router manufacturers often use concepts such as "dual-band" in their promotions. When we connect to WiFi networks, we often see the words 2.4G and 5G. At the same time, wh...
Firefly was detained for being a hooligan, but he refused to accept it: Who was giving off electricity? Who was streaking? Who has an exhibitionist fetish? The toilet is dark and I am not allowed to t...
Dear experts, this is a dual-integration AD circuit for analog-to-digital conversion. The left in is the voltage to be measured, 0 to -5V negative value, the right three are the comparator inputs to t...
[size=4]Ultra-wideband positioning principle: [/size] [size=4] By deploying base stations indoors (outdoors), carrying tags on the positioning target; tags transmit ultra-wideband signals, base statio...
The USB Type-C interface, developed by the USB -IF organization, was recognized by Apple, Google, Intel and other manufacturers as early as 2014, and related products were launched in 2015. Compared w...
A few days ago, I was looking for the problem that the NAND Flash emulation USB disk program could not be formatted. On the night of the Mid-Autumn Festival, I was still working hard in the laborator...[Details]
According to foreign media reports, Ford Motor Company announced that the company will jointly develop the first pure electric model of its luxury brand Lincoln with electric vehicle startup Rivian. ...[Details]
In electric vehicles , achieving reliable energy density requires batteries of a certain size and weight. In addition, battery degradation during the charging cycle is also a critical issue because o...[Details]
Requirements
Oscillation
Period T = 1~10S, select resistance and capacitance parameters, and draw a connection diagram.
Solution
The circuit is shown in Figure 9-4. ...[Details]
At present, the common maintenance problems of electronic scale sensors in China are based on the principle of resistance strain type weighing sensors, which are becoming more and more common. Electro...[Details]
1 Introduction
Civilian non-power nuclear technology is a high-tech technology that the country encourages to develop. Among them, nuclear logging technology is one of the cutting-edge logging t...[Details]
According to foreign media reports, Ford has developed a "night driving mode" that can limit the speed of the vehicle after dark. Ford submitted a patent application for a night speed limiter in Au...[Details]
Yesterday, Huami Technology’s official Weibo account announced that it will hold a 2019 new product launch conference in Beijing on the 27th of this month. Judging from the conference theme of “Run, ...[Details]
If we want to summarize the top ten hot events in 2019, one of them must be about e-cigarettes. Tianya Shusheng, a star blogger from Breadboard, combined recent events in the e-cigarette industry and...[Details]
1 Introduction
Controller Area Network (CAN) is a special serial data communication bus developed by Robert Bosch in Germany for the automotive industry in the early 1980s. After years of develop...[Details]
On November 3, Continental showcased its innovative display solution, the ShyTech display, which can provide intelligent support to keep drivers focused on important information and is expected to be...[Details]
In some areas where power outages are common, electrical appliances are not turned off after a power outage. Once power is restored, they will automatically power on and work. This can result in wa...[Details]
Luzhou Laojiao uses Commvault solutions to increase data backup success rate by 85%, providing strong support for its business expansion Commvault, a recognized leader in data management software ...[Details]
Not all products with intelligent video analysis functions can be classified as "intelligent". The determination of "intelligent" products depends on intelligent evaluation - by observing the funct...[Details]
SkyTraq Technology has launched the PX1120D dead reckoning GNSS/inertial measurement unit (IMU) for the automotive OEM and aftermarket markets.
(Image source: SkyTraq Technology)
...[Details]