5431.6253.252

Description
Mains Power Connector
CategoryThe connector    The connector   
File Size677KB,4 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Download Datasheet Parametric View All

5431.6253.252 Overview

Mains Power Connector

5431.6253.252 Parametric

Parameter NameAttribute value
MakerSCHURTER
Reach Compliance Codecompli
Connector typeMAINS POWER CONNECTOR
Manufacturer's serial number54
Power Entry Modules with Line Filter
Felcom 54
www.schurter.com/pg06
Standard- or Medical-Filter
IEC Appliance Inlet C14 Modular Assembling Options
5411.XX5X.XXX
Appliance inlet
Fuseholder
Line filter
5431.X05X.XXX
Appliance inlet
Appliance outlet
Switch
Line filter
C14
70° C
F
70° C
- Panel Mount:
Snap-in version from front side
- 2 - 5 Functions:
Appliance Inlet Protection class I, Connector, Line Switch 2-pole, Fuse-
holder for fuse-links 5 x 20 mm 1- or 2-pole, Line filter in standard and
medical version
- Solder terminals 3.5 x 0.8 mm or quick connect terminals 6.3 x 0.8
mm
Description
Characteristics
- Modular component selection
- Individual components soldered on a printed circuit board
- Plug removal necessary for fuse-link replacement
Fuse drawer meets requirements of medical standard IEC/EN 60601-1
The fuseholder is accessible from the equipment front
- Technical data of filter-components see blockfilter type 5500
- Fully insulated from the rear
- Qualified for use in equipment according IEC/EN 60950
Approvals
Other versions on request
References
Weblinks
- VDE Certificate Number: 101307
- UL File Number: E72928
- Line switch with other rocker marking
Alternative: version without line filter Felcom 64
pdf, html, General Product Information, Approvals, RoHS, CHINA-RoHS,
Mating Connectors, e-Shop, SCHURTER-Stock-Check, Distributor-
Stock-Check, Accessories, Detailed request for product
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz
1 - 10 A @ Ta 40 °C / 250 VAC; 60 Hz
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
-25 °C to 85 °C
25/085/21 acc. to IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class 1 acc. to IEC 61140
Solder terminals 3.5 x 0.8 mm or quick
connect terminals 6.3 x 0.8 mm
Snap-in: 1/1.2/1.5/2/2.5/3 mm1/1.2/1.5
/2/2.5/3 mm
Thermoplastic, black, UL 94V-0
Appliance-Inlet/-Outlet
C14 acc. to IEC/EN 60320-1,
F acc. to IEC/EN 60320-2-2,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection Class 1
1 or 2 pole, Shocksafe category PC2
acc. to IEC 60127-6,
for fuse-links 5 x 20 mm
5 x 20: 2 W (1 pole)/ 1.6 W (2-pole) per
pole
Admissible power acceptance at hig-
her ambient temperature see derating
curves
Rocker switch 2-pole, non-illuminated,
acc. to IEC 61058-1
Technical Details
Standard Version, IEC 60939, IEC
60601-1, UL 1283, UL 544, EN 133
200, CSA C22.2 no. 8
Technical Details
> 1'400'000 h acc. to MIL-HB-217 F
Fuseholder
Allowable Operation Temp.
Climatic Category
Degree of Protection
Protection Class
Terminal
Panel Thickness s
Material: Housing
Rated Power Acceptance @
Ta 23 °C
Power Acceptance @ Ta >
23°C
Line Switch
Line Filter
MTBF
Connectors

TMS320F28335——Download program to flash
1. Enable CCS software to support Flash burning   Add F28335.cmd file  Block 25335_RAM_lnk.cmd as shown in the figure   2. Support copying files from Flash to RAM   Add DSP2832x_MemCopy.c  Add code in...
Jacktang DSP and ARM Processors
A question in a competition that just ended in Hangzhou
2022 TI Cup Analog Electronic System Design Invitational Competition Topic X Lissajous Figure Demonstration Device 1. Mission Design and implement a Lissajous figure demonstration device, as shown in ...
gmchen Electronics Design Contest
How to determine the device address of an I2C slave?
When you use the Ginkgo USB-I2C adapter, there is a very important information that the controlled slave address must be known, otherwise it will not be possible to communicate with the I2C slave corr...
viewtool Integrated technical exchanges
I would like to ask how to choose the type of self-recovery fuse of the mobile solid-state drive if it is broken?
I have a Toshiba 2T portable solid-state hard drive that has been broken for about a year. I have left it there without taking care of it. The last time it broke was when I plugged it into the USB por...
sky999 Mobile and portable
Summary: RCSN plays with Yatli's new product AT32F437
[url=home.php?mod=spaceuid=530197]@RCSN[/url] AT32F437 Play (1) --- Collect and upload images Play with AT32F437 (2) --- Simple identification of QR codePlaying with AT32F437 (3) --- USB OTG periphera...
EEWORLD社区 Domestic Chip Exchange
【AT-START-F425 Review】-Unboxing Review and Learning Record
【AT-START-F425 Review】- Unboxing review and learning records1. Unboxing 1. Thank you for the official trial opportunity. 2. The official version is very user-friendly, and the onboard CMSIS-DAP Debugg...
小火苗 Domestic Chip Exchange

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号