• These low noise power supplies are FCC class B compliant.
PART NUMBERS AND RATINGS
Part No.
FCP-031
FCP-031B
FCP-032
FCP-032B
FCP-101
FCP-101B
FCP-102
FCP-102B
Maximum output power Output 1(V
1
)
(W)
Voltage(V)
2.9
3
9.6
9.6
+12
+15
+12
+15
FCP, FCP-B Series
Current(A)
0.01 to 0.12
0.01 to 0.1
0.04 to 0.4
0.03 to 0.32
Output 2(V
2
)
Voltage(V)
–12
–15
–12
–15
Current(A)
0.01 to 0.12
0.01 to 0.1
0.04 to 0.4
0.03 to 0.32
TERMINAL DESIGNATIONS AND FUNCTIONS
V.ADJ
1
V
1
0V
V
2
+15V
0.32A
DC OUTPUT
–15V
0.32A
POWER SUPPLY
FCP-102
2
3
100-120V
50-60Hz
L
0.35A
AC INPUT
N
Terminal No. 1: DC output terminals(V
1
, 0V, V
2
)
Connect to load.
V
1
:+output
0V:V
1
, V
2
ground
V
2
:–output
Terminal No. 2: Ground terminal( )
For input line.
Terminal No. 3: AC input terminals(L, N, AC INPUT)
Connect to AC. 100 to 120V single phase power supply.
Specifications which provide more details for the proper and safe use of the described product are available upon request.
All specifications are subject to change without notice.
Power Supplies
AC Input
Multi Output, General-Purpose
SPECIFICATIONS
3W TYPE
Part No.
Output voltage, current
∗
1
V
1
V
2
W
FCP-031
FCP-031B
+12V • 0.12A
–12V • 0.12A
2.9
FCP, FCP-B Series
Maximum output power
Input requirements
Input voltage Eac
V
Input frequency
Hz
Input current
A
Surge current
A
Leakage current
mA
Efficiency
%
Output characteristics
Rated output voltage
V
Voltage variable range
V
A
Maximum output current
∗1
∗2
A
Minimum output current
V
Output setting con- Voltage
ditions
Current
A
Input variation
%
Load variation
%
Temperature
Voltage stability
%
variation
Drift
%
Dynamic load
%/ms
Ripple Ep-p
mV
Ripple noise Ep-p
mV
Start up time
ms
Hold up time
ms
Accessory equipment
Operation indicator
Overvoltage protection
Overcurrent protection
Remote ON-OFF
Remote sensing
Output voltage external variable function
Standards
Safety standards
Noise terminal voltage
Construction
External dimensions H×W×L
mm
Weight
g
Mounting method
Case and cover
Input and output cables
∗
1
Current
∗
2
The
FCP-032
FCP-032B
+15V • 0.1A
–15V • 0.1A
3
85 to 132[Rating:100-120]
47 to 66[Single phase][Rating:50-60]
0.08typ.[85V, 25°C, input and output ratings](Output rating:0.1max.)
16max.[25°C, input and output ratings, cold start]
0.5max.[25°C, input and output ratings]
64typ.[25°C, input and output ratings]
–12[V
2
]
+12[V
1
]
10.8 to 13.2[V
2
varies simultaneously as V
1
.]
0.12
0.12
0.01
0.01
12.1
—
0.12
0.12
0.1typ.[Within the input voltage range]
0.8typ.[10 to 100% load]
1typ.[0 to +50°C ]
1max.[25°C, input and output ratings, after input voltage ON for 30min to 8h]
±4max./1max.[50 to 100% sudden load change]
80
150
100max.
20min.
None
Uses overvoltage prevention
∗3
Fixed voltage threshold type, automatic recovery.
None
None
None
UL478, CSA ELECTRICAL BULLETIN No.1402 approved.
FCC class B compliant.
19×55×50[Except input and output terminals]
80max.
Can be attached to 1side.
Nonflammable resin
—
+15[V
1
]
–15[V
2
]
13.5 to 16.5[V
2
varies simultaneously as V
1
.]
0.1
0.1
0.01
0.01
15.1
—
0.1
0.1
Total variation ±3max.(±1typ.)
rating(maximum output current) is determined for 0 to +50°C. Derating is required when used outside this temperature range.
output load variation is determined within the range set by the minimum output current and the maximum output current. Nominal values might pos-
sibly not be satisfied when output is below the minimum output current.
∗
3
Although there is no built-in overvoltage protection circuit, the overvoltage prevention method is used for circuit design, thereby preventing overvoltage.
Specifications which provide more details for the proper and safe use of the described product are available upon request.
All specifications are subject to change without notice.
Power Supplies
AC Input
Multi Output, General-Purpose
SPECIFICATIONS
10W TYPE
Part No.
Output voltage, current
∗
1
V
1
V
2
W
FCP-101
FCP-101B
+12V • 0.4A
–12V • 0.4A
9.6
FCP, FCP-B Series
Maximum output power
Input requirements
Input voltage Eac
V
Input frequency
Hz
Input current
A
Surge current
A
Leakage current
mA
Efficiency
%
Output characteristics
Rated output voltage
V
Voltage variable range
V
A
Maximum output current
∗1
∗2
A
Minimum output current
V
Output setting con- Voltage
ditions
Current
A
Input variation
%
Load variation
%
Temperature
Voltage stability
%
variation
Drift
%
Dynamic load
%/ms
Ripple Ep-p
mV
Ripple noise Ep-p
mV
Start up time
ms
Hold up time
ms
Accessory equipment
Operation indicator
Overvoltage protection
Overcurrent protection
Remote ON-OFF
Remote sensing
Output voltage external variable function
Standards
Safety standards
Noise terminal voltage
Construction
External dimensions H×W×L
mm
Weight
g
Mounting method
Case and cover
Input and output cables
∗1
Current
∗2
The
FCP-102
FCP-102B
+15V • 0.32A
–15V • 0.32A
9.6
85 to 132[Rating:100-120]
47 to 66[Single phase][Rating:50-60]
0.25typ.[85V, 25°C, input and output ratings](Output rating :0.1max.)
16max.[25°C, input and output ratings, cold start]
0.5max.[25°C, input and output ratings]
75typ.[25°C, input and output ratings]
–12[V
2
]
+12[V
1
]
10.8 to 13.2[V
2
varies simultaneously as V
1
.]
0.4
0.4
0.04
0.04
12.1
—
0.4
0.4
0.1typ.[Within the input voltage range]
0.8typ.[10 to 100% load]
1typ.[0 to +50°C ]
1max.[25°C, input and output ratings, after input voltage ON for 30min to 8h]
±4max./1max.[50 to 100% sudden load change]
80
150
100max.
20min.
None
Uses overvoltage prevention
∗3
Fixed voltage threshold type, automatic recovery.
None
None
None
UL478, CSA ELECTRICAL BULLETIN No.1402 approved.
FCC class B compliant.
19×55×80[Except input and output terminals]
100max.
Can be attached to 1side.
Nonflammable resin
—
+15[V
1
]
–15[V
2
]
13.5 to 16.5[V
2
varies simultaneously as V
1
.]
0.32
0.32
0.03
0.03
15.1
—
0.32
0.32
Total variation ±3max.(±1typ.)
rating(maximum output current) is determined for 0 to +50°C. Derating is required when used outside this temperature range.
output load variation is determined within the range set by the minimum output current and the maximum output current. Nominal values might possi-
bly not be satisfied when output is below the minimum output current.
∗
3
Although there is no built-in overvoltage protection circuit, the overvoltage prevention method is used for circuit design, thereby preventing overvoltage.
A152_FCP
980403
Specifications which provide more details for the proper and safe use of the described product are available upon request.