EEWORLDEEWORLDEEWORLD

Part Number

Search

CFM-6025V-125-107

Description
FAN AXIAL 60X25MM 12VDC WIRE
CategoryThermal management products   
File Size1MB,15 Pages
ManufacturerCUI
Websitehttp://www.cui.com
Environmental Compliance
Download Datasheet Parametric View All

CFM-6025V-125-107 Online Shopping

Suppliers Part Number Price MOQ In stock  
CFM-6025V-125-107 - - View Buy Now

CFM-6025V-125-107 Overview

FAN AXIAL 60X25MM 12VDC WIRE

CFM-6025V-125-107 Parametric

Parameter NameAttribute value
Voltage - Rated12VDC
size/dimensionsSquare - 60mm long x 60mm high
width25.00mm
airflow13.8 CFM(0.386m³/min)
static pressure0.060 inches water column (14.9 Pa)
Bearing typeomniCOOL™ Magnetic Sleeves
Fan typeTube shaft type
characteristicWith automatic restart function
noise10.7 dB(A)
Power (W)320mW
RPM2500 RPM
Termination2 leads
Intrusion protection-
Operating temperature14 ~ 158°F (-10 ~ 70°C)
ApprovalCE,cURus,TUV
weight0.099 lbs (44.91g)
Rated current0.026A
voltage range4.5 ~ 13.8VDC
Material - FramePolybutylene terephthalate (PBT)
Material - BladePolybutylene terephthalate (PBT)
Service life at different temperatures70,000 hours at 40°C
For more information, please visit the
product page.
date
page
12/11/2017
1 of 15
SERIES:
CFM-60V
DESCRIPTION:
DC AXIAL FAN
FEATURES
• omniCOOL
TM
bearing system
• 60 x 60 mm frame
• multiple speed options for different cooling needs
• tachometer signal and rotation detect options available
• auto restart protection standard on all models
MODEL
rated
(Vdc)
input
voltage
range
(Vdc)
input
current
1
max
(mA)
input
power
1
max
(W)
rated
speed
1
typ
(RPM±15%)
air
flow
2
(CFM)
static
pressure
3
(inch H
2
O)
noise
4
max
(dBA)
CFM-6010V-130-205
CFM-6010V-135-250
CFM-6010V-140-285
CFM-6015V-122-145
CFM-6015V-130-213
CFM-6015V-139-292
CFM-6015V-147-342
CFM-6015V-154-362
CFM-6015V-239-292
CFM-6015V-247-342
CFM-6015V-254-362
CFM-6020V-131-210
CFM-6020V-142-280
CFM-6020V-150-335
CFM-6020V-157-390
CFM-6020V-230-230
CFM-6020V-237-280
CFM-6020V-245-335
CFM-6025V-125-107
CFM-6025V-131-167
CFM-6025V-138-220
CFM-6025V-145-270
CFM-6025V-152-312
CFM-6025V-231-167
Notes:
1.
2.
3.
4.
5.
12
12
12
12
12
12
12
12
24
24
24
12
12
12
12
24
24
24
12
12
12
12
12
24
6~13.8
4.5~13.8
4.5~13.8
4.5~13.8
4.5~13.8
4.5~13.8
4.5~13.8
4.5~13.8
8~27.6
8~27.6
8~27.6
4.5~13.8
4.5~13.8
4.5~13.8
4.5~13.8
8~27.6
8~27.6
8~27.6
4.5~13.8
4.5~13.8
4.5~13.8
4.5~13.8
4.5~13.8
8~27.6
56
87
125
29
58
79
147
213
48
87
98
48
75
115
164
29
42
87
26
53
83
87
150
28
0.68
1.05
1.50
0.35
0.70
0.95
1.77
2.56
1.16
2.09
2.36
0.58
0.90
1.38
1.97
0.70
1.01
2.09
0.32
0.64
1.00
1.05
1.80
0.68
3000
3500
4000
2200
3000
3900
4700
5400
3900
4700
5400
3100
4200
5000
5700
3100
4200
5700
2500
3100
3800
4500
5200
3100
12.2
14.3
16.3
12.7
17.6
22.8
26.4
30.4
22.8
26.4
30.4
16.5
19.0
23.0
25.5
16.5
19.0
25.5
13.8
16.0
19.3
23.5
27.0
16.0
0.08
0.10
0.12
0.04
0.12
0.14
0.18
0.22
0.14
0.18
0.22
0.10
0.16
0.21
0.27
0.10
0.16
0.27
0.06
0.10
0.15
0.21
0.31
0.10
20.5
25.0
28.5
14.5
21.3
29.2
34.2
36.2
29.2
34.2
36.2
21.0
28.0
33.5
39.0
21.0
28.0
39.0
10.7
16.7
22.0
27.0
31.2
16.7
At rated voltage, 25°C, 0 inch H
2
0 static pressure, after 10 minutes
As per AMCA 210 or DIN 24163, at rated voltage, stabilized RPM, 0 inch H
2
0 static pressure
As per AMCA 210 or DIN 24163, at rated voltage, stabilized RPM, 0 CFM airflow.
Measured in a semi-anechoic chamber with background noise < 15 dBA at 1 m from the fan intake.
All specifications are measured at 25°C, 65% relative humidity unless otherwise specified.
cui.com
I would like to ask how the following is calculated:
These are two examples about active filters in Chapter 3 of "Circuit Design Based on Operational Amplifier Design and Analog Integrated Circuits". Since my theoretical foundation is not very good, I d...
sunboy25 Analog electronics
ECG data collection and filtering encountered a bottleneck
[i=s]This post was last edited by w494143467 on 2020-10-17 09:44[/i]At the beginning, the data collected contained a lot of high-frequency noise, such as AC power, electromyography and some other infl...
w494143467 Medical Electronics
Mech warriors appear on the scene: wheeled robots are deployed in the fight against epidemics
The development of science and technology has enabled us to demonstrate unprecedented capabilities in the face of this epidemic. We have seen the construction of the Vulcan Mountain Hospital in 10 day...
EEWORLD社区 TI Technology Forum
December 8th Award-winning Live Broadcast | MPS New Generation Magnetic Angle Sensor MA600 Introduction and Application
Live Topic: Introduction and Application of MPS New Generation Magnetic Angle Sensor MA600 Live broadcast time: December 8, 2022 (Thursday) 10:00-11:30 am Magnetic angle sensors provide a small-sized,...
EEWORLD社区 Sensor
100 ways to make power amplifiers
100 ways to make power amplifiers...
1nnocent Analog electronics
User feedback post
Thank you for your continued support of the forum!This post is for netizens' feedback. Everyone is welcome to post comments and let us work together to make the forum better!...
okhxyyo Suggestions & Announcements

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号