Detailed use of waveform calculator in Saber simulation

Publisher:Yuexiang666Latest update time:2014-02-20 Source: 电源网 Reading articles on mobile phones Scan QR code
Read articles on your mobile phone anytime, anywhere

When I first started using Saber , I saw the waveform under CosmosScope but didn't know how to use it. I was embarrassed to add or subtract any two waveforms. Saber is very powerful, and Saber 's waveform calculator is also very powerful. There are many ways to achieve the same goal. Many times, we only need to use one of the methods, know how to use it, and be able to solve the problem. Here is a method I use.

Under CosmosScope there is the following column:

Click on this calculator icon:

Pull out any two waveforms below, Uds and the primary side waveform of the flyback transformer:

The MOS tube turns off the Uds voltage, which consists of three parts: input voltage, leakage inductance voltage, and secondary side refraction voltage:

The waveform on the primary side of the flyback transformer: when the MOS tube is turned on, it withstands the input voltage; when the MOS tube is turned off, it withstands the reverse refraction voltage and leakage inductance voltage.

Subtract Uds from the primary side of the flyback transformer using a waveform calculator to obtain the subtracted waveform. The method is as follows:

1. First, click the label on the right side of Uds with the left mouse button to select it.

2. Under the selected label, use the middle mouse wheel and click once.

3. In the waveform calculator,

At the blue font, first left-click once, then right-click once to add the waveform icon to the waveform calculator. (This step is critical)

4. Use the same method to add the primary voltage of the flyback transformer to the waveform calculator. For example:

5. Use the waveform calculator to subtract the two (click the waveform calculator minus symbol -), such as:

6. Click the waveform calculator and the green icon on the far left to display the result of subtraction.

The waveform after subtraction is as follows:

Well, that's all I have to say. I'd like to share this with my friends and if you have any good ideas, please feel free to add to them.

Reference address:Detailed use of waveform calculator in Saber simulation

Previous article:Basso model for small signal simulation of switching power supply
Next article:A classic example of SIMPLIS current mode flyback circuit simulation

Latest Power Management Articles
Change More Related Popular Components

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

About Us Customer Service Contact Information Datasheet Sitemap LatestNews


Room 1530, 15th Floor, Building B, No.18 Zhongguancun Street, Haidian District, Beijing, Postal Code: 100190 China Telephone: 008610 8235 0740

Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号