Transient Modeling and Analysis of Three-Phase UPF Boost Rectifier

Publisher:MengyunLatest update time:2012-09-25 Source: 维库电子 Reading articles on mobile phones Scan QR code
Read articles on your mobile phone anytime, anywhere

Assuming that the main circuit of the three-phase CCM UPF Boost rectifier is a six-switch bridge converter, as shown in Figure 1, a current-type dual-loop system is adopted.

The power conservation method will be applied to establish the transient analysis model of the main circuit of current control.

Assuming that the three-phase input AC voltage is balanced and symmetrical, the input voltage and current are sinusoidal, the parasitic resistance of the input inductor La, Lb, Lc of each phase, and the on-state resistance of the corresponding switch tube are represented by Ra, Rb, and Rc respectively.

The output signal of the voltage controller (expressed in current) is known.

iu < Im, Im is the amplitude of the three-phase input current

The control current signal (the control signal of the current closed-loop system) is the synthesis of Im and iu:

Figure 1 Main circuit of three-phase CCM UPF Boost rectifier



Reference address:Transient Modeling and Analysis of Three-Phase UPF Boost Rectifier

Previous article:Comparison between minimum phase system and non-minimum phase system
Next article:Power Conservation Modeling Approach

Latest Power Management Articles
Change More Related Popular Components

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

About Us Customer Service Contact Information Datasheet Sitemap LatestNews


Room 1530, 15th Floor, Building B, No.18 Zhongguancun Street, Haidian District, Beijing, Postal Code: 100190 China Telephone: 008610 8235 0740

Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号