High-voltage direct current (HVDC) transmission systems generate a large number of harmonics during the rectification and inversion process. These harmonics not only interfere with the audio communication system along the line, but also cause some adverse consequences within the power system. The traditional solution is to connect multiple groups of LC resonant passive filters in parallel on the AC and DC sides of the converter station. With the increasing requirements for the equivalent harmonic interference current index of the HVDC transmission system, it is difficult to solve the harmonic interference problem on the DC side of the HVDC system by simply adding multiple groups of passive filters. With the development of power electronics and computer technology, active filtering technology has gradually been applied to filtering on the DC side of the HVDC transmission system. Compared with the passive filter on the DC side, the DC active filter (ADF) has many advantages, mainly:
(1) In the audio range (300 Hz to 3000 Hz), the DC active filter has a strong suppression effect on each harmonic;
(2) The smaller the equivalent harmonic interference current that needs to be suppressed, the higher the performance-price ratio of the ADF;
(3) When the frequency changes or the resonance is out of tune, the ADF can also accurately track and compensate without any overload problem;
(4) Small footprint.
At present, active and passive hybrid DC active filters are mostly used in projects. This can reduce the insulation level and capacity of ADF, give full play to the advantages of passive filters in absorbing high-power harmonic currents and the high efficiency of active filters in suppressing changing frequencies and multiple harmonic currents, and achieve the best filtering effect and economic benefits.
The filtering effect of a DC active filter depends on whether it can accurately track harmonic currents and generate compensation currents in real time. This requires that the DC active filter not only has good detection accuracy, but also requires it to have a fast dynamic response speed. Reference [4] studied the tracking PWM control method. The simulation and experimental results show that the tracking effect of the hysteresis instantaneous value comparison method is the best. This paper adopts the hysteresis instantaneous value PWM comparison method in the DC active filter, and conducts experimental and simulation research on the tracking and compensation effects of this control method.
1 System structure of DC active filter
The harmonic voltage and harmonic current on the DC side of the high-voltage direct current transmission system are mainly 12th, 24th, 36th, etc. There are two ways to install active filters in the system: series or parallel. The DC filter in this article is shown in Figure 1. It is a hybrid filter system composed of a 12/24th double-tuned passive filter and an active filter in series, which are connected in parallel between the DC busbars. In the system, the active filter is connected in series to the bottom of the passive filter, and the other end is connected to the DC neutral line to reduce the insulation level of the active filter. The role of the active filter here is to reduce the double-tuned filter in
Study on the hysteresis comparison control method of DC active filter for high voltage DC transmission
The impedance of the resonance point improves its filtering effect. In addition, it filters out other harmonics that the passive filter cannot filter out (such as the 18th harmonic and some higher harmonics that seriously interfere with communication lines). The content of these harmonic components is relatively small.
2 Working principle of DC active filter Figure 2 shows the equivalent circuit diagram of the DC side of the high-voltage DC transmission system. In the figure, is the harmonic voltage source in the system, ZS is the internal impedance of the harmonic source, ZL is the DC transmission line impedance, Zf is the impedance of the passive filter (including the leakage reactance of the coupling transformer), is the harmonic voltage source injected into the system by the active filter, and this voltage source is related to the harmonic current on the DC bus. As can be seen from Figure 2, the harmonic current on the line consists of two parts: the harmonic current generated by and the harmonic current generated by. According to the superposition principle, when it works, the harmonic current on the line is: ==·(1) When it works, the harmonic current on the line is: ==·(2)
Therefore, the total harmonic current on the line is: =+=(3) By detecting the current on the line, the signal for PWM control of the inverter of the active filter is output, and then the equivalent voltage source required for compensating the harmonic current on the line and the active filter injection system is obtained. Let =-k(4)
From equations (3) and (4), we can get: =·(5)
It can be seen from formula (5) that when k=0, the active filter does not work, and the harmonic current on the line depends on the filtering effect of the passive filter; when k>0, the active filter and the passive filter form a hybrid filter to jointly suppress the harmonic current on the line. It can also be seen that when k is large enough, the harmonic current on the line can be completely filtered out. In fact, k cannot be large enough, so the harmonic current can only be suppressed and eliminated to a certain extent.
3 DC active filter control system structure diagram According to the above analysis of the working principle of the active filter, the control system structure diagram of the active filter can be obtained as shown in Figure 3. The current on the line is detected by the current detection circuit, and the harmonic current signal on the line is obtained through the Butterworth low-pass filter circuit. The harmonic current signal is used as a given signal to generate a PWM control signal, and a deviation signal is obtained by comparing it with the active filter feedback signal. The hysteresis comparator obtains the PWM signal for controlling the on and off of the main circuit switch device according to the deviation signal, thereby obtaining a voltage that suppresses the line harmonic current, so as to achieve the purpose of suppressing harmonics by the active filter.
4 DC active current using hysteresis instantaneous value comparison method
Simulation of filter compensation performance
This paper uses the power electronic circuit automatic control system simulation software PECS developed by this research group for simulation. The voltage on the DC bus of this system is about 500V, the load is a resistive load, the current on the bus is about 51A, and the loop width of the hysteresis comparator in the control circuit is about 5% of the input error signal (the difference between the given signal and the feedback signal). The simulation results of the active filter are given below. Figure 4 shows the current waveform and spectrum of the line when only the passive filter is working, and Figure 5 shows the current waveform on the line when the passive and active filters are working at the same time, the compensation voltage waveform output by the active filter, and the spectrum of the current waveform.
Figure 1 Structure diagram of hybrid DC active filter system
Figure 2 Equivalent circuit diagram of DC active filter
Figure 3 DC active filter control system structure diagram
Figure 4 Current waveform and spectrum of the line when only the passive filter is working
(a) Current waveform on the line (b) Spectrum of the current waveform
Figure 5 Simulation results when passive and active filters work simultaneously
(a) Compensation voltage waveform output by active filter
(b) Current waveform on the line when passive plus active filter
(c) Current waveform spectrum of the line when passive plus active filter is used
Figure 6 Experimental waveform with only passive filter
Figure 7 Experimental waveform of passive plus active filter
5 DC active filtering using hysteresis instantaneous value comparison method
Experimental study on compensation performance of the
Using Tektronix's TD340 digital oscilloscope, the experimental waveforms of passive filter only and passive plus active filter are obtained, as shown in Figure 6 and Figure 7. It can be seen from the figure that the addition of active filter has a significant effect on eliminating low-order harmonics, but increases the high-order harmonic components, which is consistent with the simulation results.
6 Conclusion
This paper aims at the hybrid filter system of passive-active filter, and adopts the hysteresis loop instantaneous value comparison method to obtain the PWM signal to control the on and off of the switch device of the active filter inverter. This paper analyzes the working principle of the DC active filter and designs the corresponding control circuit. The simulation experiment results show that the DC active filter using the hysteresis loop instantaneous value comparison control method has a fast dynamic response speed, good tracking effect, and obvious compensation effect for low-order harmonics, but it increases the component of high-order harmonics. This control method
Study on the hysteresis comparison control method of DC active filter for high voltage DC transmission
The biggest disadvantage of this method is that the switching frequency of the device is not fixed, and further research is needed in this regard.
Previous article:Current status and prospects of small and medium power inverters for photovoltaic systems
Next article:Analysis of Equivalent Inductance in AC Regulated Voltage Stabilized Power Supply
Recommended ReadingLatest update time:2024-11-16 19:33
- Popular Resources
- Popular amplifiers
- 西门子S7-12001500 PLC SCL语言编程从入门到精通 (北岛李工)
- New Energy Vehicle Detection and Diagnosis Experiment (Edited by Mao Caiyun, Zhou Xien, and Long Jiwen)
- Virtualization Technology Practice Guide - High-efficiency and low-cost solutions for small and medium-sized enterprises (Wang Chunhai)
- ESP32-S3 source code
- MathWorks and NXP Collaborate to Launch Model-Based Design Toolbox for Battery Management Systems
- STMicroelectronics' advanced galvanically isolated gate driver STGAP3S provides flexible protection for IGBTs and SiC MOSFETs
- New diaphragm-free solid-state lithium battery technology is launched: the distance between the positive and negative electrodes is less than 0.000001 meters
- [“Source” Observe the Autumn Series] Application and testing of the next generation of semiconductor gallium oxide device photodetectors
- 采用自主设计封装,绝缘电阻显著提高!ROHM开发出更高电压xEV系统的SiC肖特基势垒二极管
- Will GaN replace SiC? PI's disruptive 1700V InnoMux2 is here to demonstrate
- From Isolation to the Third and a Half Generation: Understanding Naxinwei's Gate Driver IC in One Article
- The appeal of 48 V technology: importance, benefits and key factors in system-level applications
- Important breakthrough in recycling of used lithium-ion batteries
- Innolux's intelligent steer-by-wire solution makes cars smarter and safer
- 8051 MCU - Parity Check
- How to efficiently balance the sensitivity of tactile sensing interfaces
- What should I do if the servo motor shakes? What causes the servo motor to shake quickly?
- 【Brushless Motor】Analysis of three-phase BLDC motor and sharing of two popular development boards
- Midea Industrial Technology's subsidiaries Clou Electronics and Hekang New Energy jointly appeared at the Munich Battery Energy Storage Exhibition and Solar Energy Exhibition
- Guoxin Sichen | Application of ferroelectric memory PB85RS2MC in power battery management, with a capacity of 2M
- Analysis of common faults of frequency converter
- In a head-on competition with Qualcomm, what kind of cockpit products has Intel come up with?
- Dalian Rongke's all-vanadium liquid flow battery energy storage equipment industrialization project has entered the sprint stage before production
- Allegro MicroSystems Introduces Advanced Magnetic and Inductive Position Sensing Solutions at Electronica 2024
- Car key in the left hand, liveness detection radar in the right hand, UWB is imperative for cars!
- After a decade of rapid development, domestic CIS has entered the market
- Aegis Dagger Battery + Thor EM-i Super Hybrid, Geely New Energy has thrown out two "king bombs"
- A brief discussion on functional safety - fault, error, and failure
- In the smart car 2.0 cycle, these core industry chains are facing major opportunities!
- The United States and Japan are developing new batteries. CATL faces challenges? How should China's new energy battery industry respond?
- Murata launches high-precision 6-axis inertial sensor for automobiles
- Ford patents pre-charge alarm to help save costs and respond to emergencies
- New real-time microcontroller system from Texas Instruments enables smarter processing in automotive and industrial applications
- SinlinxA33 development board uses MIPI DSI screen
- Install Runhe Neptune Hongmeng system on w801kit
- DSPC6678 on-chip storage space allocation mechanism
- Ask a silly question about f_mount()!
- [Evaluation of SGP40] + Cloud platform configuration for IoT remote monitoring application development
- [RVB2601 creative application development] + AHT10 temperature and humidity sensor
- A nice frame diagram
- Measured CC2530 OSAL sleep wake-up time, current, and power consumption
- Problem with the start address of SDRAM W9825G6KH
- How to analyze this circuit