The sealing design of the display panel of the magnetic flap level gauge is very important. However, at present, most of the display panels of the domestic magnetic flap level gauges have only two covers at both ends that are simply fixed with screws. Since no sealing measures are taken, this has buried hidden dangers for the reliability of the magnetic flap level gauge. Generally speaking, the poor sealing design defects of the display panel of the magnetic flap level gauge usually cause the following disadvantages:
First: The display panel is not sealed tightly, which may cause the magnetic flap level gauge to flip abnormally.
Rainwater and dust can easily enter the display cavity, causing the flap surface to become damp and dust to adhere to the surface, affecting the normal flipping of the flap; humid water vapor makes the flap easy to freeze and get stuck in the low temperature environment in winter, causing abnormal flipping and failure to indicate the liquid level normally.
Second: The display panel is not sealed tightly, which can easily reduce the visibility of the magnetic flap level gauge.
Under low temperature and humid conditions, the water vapor in the display cavity causes condensation and frost on the inner surface of the protective cover, which greatly reduces the visibility of the magnetic flap level gauge.
Third: The display panel is not tightly sealed, which can easily cause foreign matter to accumulate and hinder the flipping of the flap.
Flying insects and dust from outside can easily enter the interior, and easily breed fungi in a humid water vapor environment, which will hinder the flipping of the flap over time.
Combining the above three points, the importance of sealing design of the display panel of the magnetic flap level gauge can be seen. It can be said that sealing design of the display panel of the magnetic flap level gauge is an important measure to improve the reliability of the magnetic flap level gauge product.
In view of the defects of insufficient sealing design of the display panel of the traditional magnetic flap level gauge, Shenzhen Jiwei Automation Technology Co., Ltd. has taken the following two targeted measures for the sealing design of the display panel of the magnetic flap level gauge:
First, add a sealing component at the upper and lower ends of the display panel of the magnetic flap level gauge, using a plug-type structure, and then use special sealant for sealing;
Secondly, an oblique angle is added between the contact surface of the aluminum profile and the glass cover to increase the accommodation gap of the glass glue to improve the sealing of the panel.
By taking the above two sealing design measures, the Jiwei magnetic flap level gauge effectively avoids the above defects of the traditional magnetic flap level gauge, and significantly improves the working reliability of the magnetic flap level gauge.
Previous article:Why Ring-11 tuning fork level switch can achieve reliable measurement of liquefied natural gas?
Next article:How to choose the magnetic float of the magnetic flap level gauge
- From probes to power supplies, Tektronix is leading the way in comprehensive innovation in power electronics testing
- Seizing the Opportunities in the Chinese Application Market: NI's Challenges and Answers
- Tektronix Launches Breakthrough Power Measurement Tools to Accelerate Innovation as Global Electrification Accelerates
- Not all oscilloscopes are created equal: Why ADCs and low noise floor matter
- Enable TekHSI high-speed interface function to accelerate the remote transmission of waveform data
- How to measure the quality of soft start thyristor
- How to use a multimeter to judge whether a soft starter is good or bad
- What are the advantages and disadvantages of non-contact temperature sensors?
- In what situations are non-contact temperature sensors widely used?
- LED chemical incompatibility test to see which chemicals LEDs can be used with
- Application of ARM9 hardware coprocessor on WinCE embedded motherboard
- What are the key points for selecting rotor flowmeter?
- LM317 high power charger circuit
- A brief analysis of Embest's application and development of embedded medical devices
- Single-phase RC protection circuit
- stm32 PVD programmable voltage monitor
- Introduction and measurement of edge trigger and level trigger of 51 single chip microcomputer
- Improved design of Linux system software shell protection technology
- What to do if the ABB robot protection device stops
- Analysis of the application of several common contact parts in high-voltage connectors of new energy vehicles
- Wiring harness durability test and contact voltage drop test method
- From probes to power supplies, Tektronix is leading the way in comprehensive innovation in power electronics testing
- From probes to power supplies, Tektronix is leading the way in comprehensive innovation in power electronics testing
- Sn-doped CuO nanostructure-based ethanol gas sensor for real-time drunk driving detection in vehicles
- Design considerations for automotive battery wiring harness
- Do you know all the various motors commonly used in automotive electronics?
- What are the functions of the Internet of Vehicles? What are the uses and benefits of the Internet of Vehicles?
- Power Inverter - A critical safety system for electric vehicles
- Analysis of the information security mechanism of AUTOSAR, the automotive embedded software framework
- [GD32L233C-START Review] 3. DMA issues
- #idlemarket#Selling GigaDevice GD32 E231C-START development board
- Goodbye 2019 ~ Hello 2020 - Looking back at 2019 and planning for 2020
- 【Home Smart Dashboard】Project Submission
- FPGA design ideas and techniques: data interface synchronization
- Together: About the GD32L233 development board unpacking test
- EEWORLD University Hall----Research and development of high-speed motors
- How to choose between different chips in TI's Sub-1GHz product line?
- Why does C6000 need Cache?
- What are the benefits of using an op amp to drive a MOS tube? Who knows? Tell me