High voltage insulation resistance tester is a commonly used insulation resistance tester product, which is suitable for insulation testing in maintenance, repair and testing machine calibration of various electrical equipment . It has the advantages of stable performance, high reliability and easy maintenance. Today, the editor mainly introduces the measurement method of high voltage insulation resistance tester, hoping to help users better apply the product.
Measurement method of high voltage insulation resistance tester
1) Insert two grounding probes into the ground at a distance of 20m and 40m from the grounding body respectively along the radial direction of the grounding body, with an insertion depth of 400mm.
Ground resistance test uses: a) actual operation b) equivalent principle
2) Place the ground resistance meter flat near the grounding body and connect the wires. The wiring method is as follows:
① Use the shortest dedicated wire to connect the grounding body to the terminal "E1" of the grounding measuring instrument (three-terminal measuring instrument) or to the common terminal after "C2" is short-circuited (four-terminal measuring instrument).
② Use the longest dedicated wire to connect the measuring probe (current probe) 40m away from the grounding body to the connecting button "C1" of the measuring instrument.
③ Use the remaining length of the dedicated wire in the middle to connect the measuring probe (potential probe) ⒛m away from the grounding body to the terminal "P1" of the measuring instrument.
3) After placing the measuring instrument horizontally, check whether the pointer of the galvanometer points to the center line. If not, adjust the "zero adjuster" to make the pointer of the measuring instrument point to the center line.
4) Set the "magnification scale" (or coarse adjustment knob) to the maximum magnification and slowly turn the generator handle (the pointer begins to deviate), while turning the "measurement dial" (or fine adjustment knob) to make the galvanometer pointer point to the center line.
5) When the pointer of the galvanometer is close to balance (the pointer is close to the center line), speed up the shaking handle to make its speed reach above 120r/min, and at the same time adjust the "measuring dial" so that the pointer points to the center line.
6) If the reading of the "measurement scale" is too small (less than 1) and difficult to read accurately, it means that the magnification scale is too large. At this time, the "magnification scale" should be set to a smaller multiple, and the "measurement scale" should be readjusted so that the pointer points to the center line and the accurate reading is read.
7) Calculate the measurement result, that is, R ground = “magnification scale” reading × “measurement scale” reading.
Previous article:A brief discussion on the correct measurement method of insulation resistance tester
Next article:How to use the insulation resistance tester correctly
- Popular Resources
- Popular amplifiers
- Keysight Technologies Helps Samsung Electronics Successfully Validate FiRa® 2.0 Safe Distance Measurement Test Case
- From probes to power supplies, Tektronix is leading the way in comprehensive innovation in power electronics testing
- Seizing the Opportunities in the Chinese Application Market: NI's Challenges and Answers
- Tektronix Launches Breakthrough Power Measurement Tools to Accelerate Innovation as Global Electrification Accelerates
- Not all oscilloscopes are created equal: Why ADCs and low noise floor matter
- Enable TekHSI high-speed interface function to accelerate the remote transmission of waveform data
- How to measure the quality of soft start thyristor
- How to use a multimeter to judge whether a soft starter is good or bad
- What are the advantages and disadvantages of non-contact temperature sensors?
- LED chemical incompatibility test to see which chemicals LEDs can be used with
- Application of ARM9 hardware coprocessor on WinCE embedded motherboard
- What are the key points for selecting rotor flowmeter?
- LM317 high power charger circuit
- A brief analysis of Embest's application and development of embedded medical devices
- Single-phase RC protection circuit
- stm32 PVD programmable voltage monitor
- Introduction and measurement of edge trigger and level trigger of 51 single chip microcomputer
- Improved design of Linux system software shell protection technology
- What to do if the ABB robot protection device stops
- Allegro MicroSystems Introduces Advanced Magnetic and Inductive Position Sensing Solutions at Electronica 2024
- Car key in the left hand, liveness detection radar in the right hand, UWB is imperative for cars!
- After a decade of rapid development, domestic CIS has entered the market
- Aegis Dagger Battery + Thor EM-i Super Hybrid, Geely New Energy has thrown out two "king bombs"
- A brief discussion on functional safety - fault, error, and failure
- In the smart car 2.0 cycle, these core industry chains are facing major opportunities!
- The United States and Japan are developing new batteries. CATL faces challenges? How should China's new energy battery industry respond?
- Murata launches high-precision 6-axis inertial sensor for automobiles
- Ford patents pre-charge alarm to help save costs and respond to emergencies
- New real-time microcontroller system from Texas Instruments enables smarter processing in automotive and industrial applications
- The difference between ordinary diode and Zener diode
- Why not promote the monopoly of shared bicycles?
- New WiFi 6E and WiFi 7 standards: markets and applications
- 【Jiajiabao】 esp32s2 lvgl running
- [AB32VG1 development board review] Light up RGB_LED
- TI buck-boost supercapacitor charging solution
- EMCV transplantation problem, first time using DSP, don't quite understand
- FPGA controls the DSP power-on reset procedure.
- EEWORLD University ---- Ultra-low power wireless MCU platform CC1310DK based on SimpleLink
- Cute color-changing LED headdress