KUEP-11D35-24 Parametric

Parameter NameAttribute value
Power relay typeIndustrial panel plug-in
Terminal limit breaking current (A)10
Coil excitation systemMonostable, DC
Coil Power Rating (DC) (mW)1800
Coil resistance (Ω)320
Coil characteristicsUL Coil Insulation Class B, Electrical Indicator Light
Coil Voltage Rating (VDC)24
Terminal switch load (minimum)300mA @ 12V
Terminal Voltage Rating (VDC)150
Insulation initial resistance (MΩ)100
Initial dielectric between terminal and coil (Vrms)2200
Initial dielectric between adjacent terminals (Vrms)2200
Terminal limit continuous current (A)10
Terminal limit short-time current (A)10
Terminal limit closing current (A)10
Open terminal insulation initial dielectric (Vrms)1200
Drive SystemDC
Initial dielectric (V) for insulation between terminals and coil2200
Coil/terminal insulation initial dielectric type (V)1500 – 2500
product weight85 g [ 2.988 oz ]
Terminal arrangement2 Form C (CO)
Terminal current type (A)5 – 10, 16
Contact Current Rating (Max) (A)10
Terminal materialAgCdO
Number of terminal poles2
Terminal typequick connect, welding
Terminal characteristicsMagnetic fuse
Relay installation typesocket
Product height48.4 mm [ 1.905 in ]
Product length38.9 mm [ 1.53 in ]
Product width35.7 mm [ 1.405 in ]
Width type (mechanical) (mm)30 – 40
Height type (mechanical) (mm)40 – 50
Length type (mechanical) (mm)35 – 40
Working group temperature range (°C)-45 – 70
Environmental Protection CategoryRTI
Ambient temperature (maximum)70 °C [ 158 °F ]
Ambient temperature category (°C)50 – 70
Encapsulation methodPackage
General Purpose Relays
Industrial Relays
KUEP Series Panel Plug-in Relay
n
n
n
n
n
Potter & Brumfield
1 Form X, 2 Form A and 2 Form C contact arrangements
10 amp current rating
Magnetic blow-out
Various mounting options
Indicator lamp available
Typical applications
DC load switching in industrial controls
Approvals
UL E22575; CSA LR15734; CE (KUEP-11 only)
Technical data of approved types on request
Coil Data
Coil voltage range
Coil insulation system according UL
Coil versions, DC coil
Coil
Rated
Operate
code
voltage
voltage
VDC
VDC
One pole versions
5
5
3.75
6
6
4.5
12
12
9.0
24
24
18.0
48
48
36.0
110
110
82.5
125
125
93.75
Two pole versions
5
5
3.75
6
6
4.5
12
12
9.0
24
24
18.0
48
48
36.0
110
110
82.5
125
125
93.75
Coil versions, AC coil
Coil
Rated
code
voltage
VAC
One pole versions
6
6
12
12
24
24
120
120
240
240
Two pole versions
6
6
12
12
24
24
120
120
240
240
Contact Data
5 to 125VDC
6 to 240VAC
Class B
Coil
resistance
Ω±10%
21
32
120
472
1800
10000
13000
14
20
80
320
1250
6720
8680
Rated coil
power
W
1.2
1.125
1.2
1.25
1.3
1.25
1.2
1.8
1.8
1.8
1.8
1.85
1.8
1.8
Contact arrangement
1 form X (NO-DM), 2 form A (NO), 2 form C (CO)
Rated voltage
150VDC
Rated current
10A
Contact material
AgCdO
AgSnOInO
Min. recommended contact load
300mA, 12VDC
Frequency of operation
360 ops./hour
360 ops./hour
Operate/releases time max.
15/10ms
Bounce time max.
17ms
Contact ratings
Type
Load
UL 508
KUEP, 1 form X, AgCdO
10A, 150VDC
1A, 300VDC
2.5 A, 170 VDC, resistive
KUEP, 2 form A, AgCdO
5 A, 150 VDC
2.5 A, 170 VDC, resistive
KUEP, 2 form C, AgCdO
3 A, 150 VDC
2.5 A, 170 VDC, resistive
10 A, 240 VAC
10 A, 32 VDC
5 FLA, 15 LRA, 250 VAC
1/3 HP, 120 VAC
5 A, 120 VAC, tungsten
1/2 HP, 250 VAC
10 FLA, 40 LRA, 125 VAC
3 A, 600 VAC
1/2 HP, 480 VAC
1/2 HP, 600 VAC
1 HP, 480 VAC, 3 phase
KUEP, 1 form X, AgSnOInO
10A, 150VDC, resistive
KUEP, 2 form A, AgSnOInO
5 A, 150 VDC, resistive
KUEP, 2 form C, AgSnOInO
3 A, 150 VDC, resistive
Mechanical endurance
Cycles
100x10
3
100x10
3
100x10
3
100x10
3
100x10
3
All figures are given for coil without preenergization, at ambient temperature +23°C.
Operate
voltage
VAC
5.1
10.2
20.4
102.0
204.0
5.1
10.2
20.4
102.0
204.0
Coil
resistance
Ω±15%
6
24
85
2250
9110
4.2
18
72
1700
7200
Rated coil
power
VA
2.0
2.0
2.0
2.1
2.1
2.8
2.8
2.8
2.9
2.9
30x10
3
100x10
3
10x10
6
ops.
100x10
3
All figures are given for coil without preenergization, at ambient temperature +23°C.
Insulation Data
Initial dielectric strength
between open contacts
between contact and coil
between adjacent contacts
Initial insulation resistance
between insulated elements
12-2016, Rev. 1216
www.te.com
© 2015 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
1200V
rms
2200V
rms
2200V
rms
100MΩ
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
1

KUEP-11D35-24 Related Products

KUEP-11D35-24 KUEP-7D17-24 KUEP-3D17-24 GRM2196S2A360JZ01B
Description KUEP-11D35-24=KU KUEP-7D17-24=KU KUEP-3D17-24=KUEP CAPACITOR, CERAMIC, MULTILAYER, 100V, S2H, 0.000036uF, SURFACE MOUNT, 0805, CHIP, ROHS COMPLIANT
Power relay type Industrial panel plug-in Industrial panel plug-in Industrial panel plug-in -
Terminal limit breaking current (A) 10 10 10 -
Coil excitation system Monostable, DC Monostable, DC Monostable, DC -
Coil Power Rating (DC) (mW) 1800 1800 850 -
Coil resistance (Ω) 320 320 472 -
Coil characteristics UL Coil Insulation Class B, Electrical Indicator Light UL Coil Insulation Class B UL Coil Insulation Class B -
Coil Voltage Rating (VDC) 24 24 24 -
Terminal switch load (minimum) 300mA @ 12V 300mA @ 12V 300mA @ 12V -
Terminal Voltage Rating (VDC) 150 150 150 -
Insulation initial resistance (MΩ) 100 100 100 -
Initial dielectric between terminal and coil (Vrms) 2200 2200 2200 -
Initial dielectric between adjacent terminals (Vrms) 2200 2200 2200 -
Terminal limit continuous current (A) 10 10 10 -
Terminal limit short-time current (A) 10 10 10 -
Terminal limit closing current (A) 10 10 10 -
Open terminal insulation initial dielectric (Vrms) 1200 1200 1200 -
Drive System DC DC DC -
Initial dielectric (V) for insulation between terminals and coil 2200 2200 2200 -
Coil/terminal insulation initial dielectric type (V) 1500 – 2500 1500 – 2500 1500 – 2500 -
product weight 85 g [ 2.988 oz ] 85 g [ 2.988 oz ] 85 g [ 2.988 oz ] -
Terminal arrangement 2 Form C (CO) 2 Form A (NO) 1 Form X (NO, bridged) -
Terminal current type (A) 5 – 10, 16 5 – 10, 16 5 – 10, 16 -
Contact Current Rating (Max) (A) 10 10 10 -
Terminal material AgCdO AgCdO AgCdO -
Number of terminal poles 2 2 1 -
Terminal type quick connect, welding PCB-THT PCB-THT -
Terminal characteristics Magnetic fuse Magnetic fuse Magnetic fuse -
Relay installation type socket socket printed circuit board, socket -
Product height 48.4 mm [ 1.905 in ] 48.4 mm [ 1.905 in ] 48.4 mm [ 1.905 in ] -
Product length 38.9 mm [ 1.53 in ] 38.9 mm [ 1.53 in ] 38.9 mm [ 1.53 in ] -
Product width 35.7 mm [ 1.405 in ] 35.7 mm [ 1.405 in ] 35.7 mm [ 1.405 in ] -
Width type (mechanical) (mm) 30 – 40 30 – 40 30 – 40 -
Height type (mechanical) (mm) 40 – 50 40 – 50 40 – 50 -
Length type (mechanical) (mm) 35 – 40 35 – 40 35 – 40 -
Working group temperature range (°C) -45 – 70 -45 – 70 -45 – 70 -
Environmental Protection Category RTI RTI RTI -
Ambient temperature (maximum) 70 °C [ 158 °F ] 70 °C [ 158 °F ] 70 °C [ 158 °F ] -
Ambient temperature category (°C) 50 – 70 50 – 70 50 – 70 -
Encapsulation method Package Package Package -
[MPS Mall Big Offer Experience Season] Unboxing
...
songshuheng Power technology
Pingtouge RVB2601 Review: Connecting to Alibaba Cloud IoT Platform
1. Introduction to ATAT stands for Attention. The AT command set is a command sent from a terminal device or a data terminal device to a terminal adapter or a data circuit terminal device. AT is a sof...
xiyue521 Domestic Chip Exchange
MSP430F5529 IO port pin interrupt study notes
A very simple program, using the IO interrupt of the key to control the LED on and off on the F5529 development board:#includeint main(void){WDTCTL = WDTPW + WDTHOLD; // Stop watchdog timer P1DIR |= B...
Aguilera Microcontroller MCU
Circuit-level electrostatic protection design techniques and ESD protection methods
The theoretical research on electrostatic discharge (ESD) is already quite mature. In order to simulate and analyze electrostatic events, many electrostatic discharge models have been designed by pred...
okhxyyo Power technology
CC3200 Kit OURS-SDK-WFB_Exploration 4——FreeRTOS Run
[i=s]This post was last edited by tinnu on 2019-2-20 15:37[/i] [b][color=#5E7384]This content was originally created by EEWORLD forum user [size=3]tinnu[/size]. If you need to reprint or use it for co...
tinnu Wireless Connectivity
The microcontroller outputs PWM wave to control the load supply voltage 0-12V adjustable
I am working on a constant temperature control system recently. The 3.3V PWM waveform output by the microcontroller is used to control the power supply voltage of the load. The load voltage is 1-12V, ...
李嘉辉 Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号