EEWORLDEEWORLDEEWORLD

Part Number

Search

2631LHC22301L380V3/3

Description
Rocker Switch, SPST, Latched, 15A, 12VDC, Screw Terminal, V-shaped Rocker Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size229KB,8 Pages
ManufacturerAPEM
Environmental Compliance
Download Datasheet Parametric View All

2631LHC22301L380V3/3 Overview

Rocker Switch, SPST, Latched, 15A, 12VDC, Screw Terminal, V-shaped Rocker Actuator, Panel Mount

2631LHC22301L380V3/3 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Reach Compliance Codecompli
ECCN codeEAR99
Actuator typeV-SHAPED ROCKER
body width18.5 mm
body height28.1 mm
Body length or diameter32 mm
Contact (AC) maximum rated R load16A@250VAC
Maximum contact current (AC)16 A
Maximum contact current (DC)15 A
Contact (DC) maximum rated R load15A@12VDC
Maximum contact voltage (AC)250 V
Maximum contact voltage (DC)12 V
Electrical life10000 Cycle(s)
illuminationGREEN LAMP
Manufacturer's serial number2600
Installation featuresPANEL MOUNT
Maximum operating temperature55 °C
Minimum operating temperature-10 °C
method of packingBULK
sealDUST PROOF; WATER PROOF
surface mountNO
Switch actionLATCHED
switch functionSPST
Switch typeROCKER SWITCH
Termination typeSCREW
Base Number Matches1
2600 series
Illuminated and non-illuminated rocker switches
Distinctive features and specifications
Three rocker shapes : plain, V-shaped or concave
Various rocker colours
Frame with protection guard on 2600LP models
UL, CSA, VDE and NF (EN 61058-1) approved
ELECTRICAL SPECIFICATIONS
• Max. current/voltage rating with resistive load and approved ratings : see table below.
• Initial contact resistance : 10mΩ max. at 1A 2VDC
• Insulation resistance : 1.000 MΩ min. at 500VDC
• Dielectric strength : 2.500 Vrms 50 Hz min. between terminals
3.000 Vrms 50 Hz min. between terminals and metal panel
• Electrical life : 10.000 cycles at full load
APPROVED RATINGS
FUNCTIONS
CSA
CSA 22-2
DIRECT CURRENT
NF
EN 61058-1
UL
UL 1054
VDE
EN 61058-1
24 VDC
12 VDC
D
ON - OFF
ON - ON
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
10A 125VAC
10A 250VAC
1/6 HP 250VAC
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
-
10(4)A 250VAC
T 85/55
-
10A
15A
ON - OFF - ON
ON - ON - ON
OTHERS
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
8A
5A
8A
10A
8A
10A
MATERIALS
GENERAL SPECIFICATIONS
• Case : melamine/polyester
• Frame : polyamide
• Actuator : polyamide
• Contacts :
A
: silver
C
: copper, silver plated
• Panel thickness : 0,8 mm to 4 mm (.031 to .157)
• Operating temperature :
- silver contacts (A) : -20°C to +125°C
- silver plated contacts (C) : -10°C to +55°C
AGENCY APPROVALS
EN 61058-1
EN 61058-1
Availability
: consult factory for details of approved models.
Marking
: approved models are standard marked.
APEM
www.apem.com
D-49
New uses for old phones (9) - File sync
Here, I recommend you to use Syncthing for file synchronization. There are already many free or paid network storages, and some mobile phones even have integrated cloud synchronization functions. Why ...
dcexpert DIY/Open Source Hardware
Near Field Communication (NFC) Transceiver Design
This near field communication (NFC) design outlines the required components and layout considerations, and provides firmware examples to illustrate how to implement NFC into an application to extract ...
Jacktang RF/Wirelessly
Guwei LCR819 bridge cannot be tested maintenance record
The weather in Guangdong is humid, and the bridge has a problem. This bridge made in Taiwan is very easy to use, the reading is very stable, and the holding capacity is also very large. Here I will se...
ylyfxzsx Creative Market
MP2459 related circuit solution
I recently used MP2459. The datasheet says that the enable pin pull-up is effective. I want to ask what is the role of R4 in the example it gives? Can it be directly connected to R5100k? What is the d...
CcKk Power technology
TI Industrial Robots Online Seminar Resource Sharing
Main Agenda of the Seminar 1. Provide a detailed introduction to the definition and classification, system considerations, and module analysis of industrial robots; 2. Count the challenges faced in in...
arui1999 Industrial Control Electronics
Power Optimized 77GHz Liquid Level Transmitter Reference Design
[i=s]This post was last edited by Jacktang on 2019-4-19 08:30[/i] TIDEP-0091 highlights the IWR14xx 76- to 81-GHz mmWave sensor power optimization strategy for tank level detection applications, displ...
Jacktang Analogue and Mixed Signal

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号