30 AMP MINIATURE POWER RELAY

AZ2800
30 AMP MINIATURE
POWER RELAY
FEATURES
DPST-NO and DPDT configuration
Meets 8 mm creepage, 4 kV dielectric
Epoxy selead version available
UL Class F (155°C) standard
UL, CUR file E44211
VDE certificate 40023442
CONTACTS
Arrangement
DPST (2 Form A)
DPDT (2 Form C)
Ratings
Resistive load:
Max. switched power: 560 W or 8310 VA
Max. switched current: 30 A (N.O.), 3 A (N.C.)
Max. switched voltage: 30 VDC* or 600 VAC
*
Note: If switching voltage is greater than 30 VDC,
GENERAL DATA
Life Expectancy
Mechanical
Electrical
Operate Time
Release Time
Minimum operations
5 x 10
7
1 x 10
5
at 30 A 277 VAC Res. (N.O.)
15 ms typical
25 ms maximum with bounce
10 ms typical
25 ms maximum with bounce
(with no coil suppression)
special precautions must be taken.
Please contact the factory.
Rated Load
UL
Normally open contacts (N.O.)
30 A at 277 VAC, General Use, 100k cycles [1][2]
10 A at 600VAC, General Use, 6k cycles [1]
1 HP at 120 VAC, 100k cycles [1][2]
2.5 HP at 240 VAC, 100k cycles [1][2]
8 FLA / 26 LRA at 600 VAC, 30k cycles [1]
Normally open contacts (N.O.), DC coils only
25.3 FLA / 110 LRA at 240 VAC, 30k cycles [1][2]
Normally closed contacts (N.C.)
3 A at 277 VAC, General Use, 100k cycles [1][2]
2 A at 480 VAC, General Use, 6k cycles [1]
1 A at 600 VAC, General Use, 6k cycles [1]
3 FLA / 3 LRA at 240 VAC, 30k cycles [1]
2 FLA / 2 LRA at 480 VAC, 30k cycles [1]
1 FLA / 1 LRA at 600 VAC, 30k cycles [1]
Dielectric Strength
1500 Vrms contact to contact
(at sea level for 1 min.)
4000 Vrms contact to coil
2000 Vrms between contact sets
Insulation Resistance
Dropout
Ambient Temperature
Operating
Vibration
Shock
10
9
ohms minimum at 500 VDC
DC: Greater than 10% of nominal coil voltage
AC: Greater than 20% of nominal coil voltage
At nominal coil voltage
DC: -40°C (-40°F) to 85°C (185°F)
AC: -40°C (-40°F) to 65°C (149°F)
0.062" (1.5 mm) DA at 10–55 Hz
Operational, 10 g for 11 ms
1
/
2
sine pulse
(no contact opening > 100usec)
Non-destructive, 100 g for 11 ms
1
/
2
sine pulse
P.B.T. polyester
Quick connect tabs
Note: Allow suitable slack on leads when wiring,
and do not subject the terminals to excessive
force
VDE
Normally open contacts (N.O.)
20 A at 250 VAC, resistive, 50k cycles [2]
Enclosure
Normally closed contacts (N.C.)
3 A at 250 VAC, resistive, 50k cycles [2]
Terminals
Material
Resistance
Silver cadmium [1], silver tin oxide [2],
< 50 milliohms initially
(at 6 V, 1 A, voltage drop method)
Max. Solvent Temp.
Max. Immersion Time
Weight
925 mW, DC coil
2.6 VA, AC coil
5 W at 20°C (68°F) ambient, DC coil
7 VA at 20°C (68°F) ambient, AC coil
48°C (86°F) at nominal coil voltage, DC coil
68°C (122°F) at nominal coil voltage, AC coil
Max. 155°C (311°F)
Packing unit in pcs
80°C (176°F)
30 seconds
86 grams
20 per plastic tray / 100 per carton box
COIL
Power
At Pickup Voltage
(typical)
Max. Continuous
Dissipation
Temperature Rise
Temperature
NOTES
1. All values at 20°C (68°F).
2. Relay may pull in with less than “Must Operate” value.
3. Specifications subject to change without notice.
-
A ZETTLER
GROUP
Company
ZETTLER electronics GmbH
Junkersstr. 3, D-82178 Puchheim, Germany
This product specification to be used only together with the application notes
which can be downloaded from http://www.ZETTLERelectronics.com/pdfs/relais/ApplicationNotes.pdf
phone: +49 89 800 97-0 office@ZETTLERelectronics.com
fax:
+49 89 800 97-200 www.ZETTLERelectronics.com
2014-09-08
EEWORLD University Hall----Kalman Filter
Kalman filter : https://training.eeworld.com.cn/course/5322Explain what a Kalman filter is and how to use it...
木犯001号 DSP and ARM Processors
Why is it necessary to add a pull-up resistor to the IO port of the OC gate output?
[size=4]A: Let's first talk about the structure of open collector output. The structure of open collector output is shown in Figure 1. The collector of the transistor on the right is not connected to ...
Aguilera Analogue and Mixed Signal
Which is the control chip of this flyback power supply?
What is the control chip in the picture below? Does anyone know the specific model of the power chip in SOT23 package? I looked at these chips: OB2263, ME8200, PT4201, FS6830, but I'm not sure...
kal9623287 Power technology
Chanel lost the lawsuit against Huawei for logo infringement. Do you think these two logos are similar?
According to foreign media reports, French luxury brand Chanel lost its trademark dispute with Huawei.The dispute began in 2017 when Huawei applied to the European Union Intellectual Property Office (...
eric_wang Talking
Several Problems of AD Sampling Circuit
I want to collect the voltage of the middle tap of the potentiometer , the power supply voltage is 100V DC. But this voltage is a bit large, so it must be divided twice.1. The voltage collected in thi...
南以浅 Analog electronics
Application Status and Thinking of AC Speed Regulation in Baosteel
This article summarizes the application of AC speed regulation in the construction of Baosteel Phase I, II and III projects. Based on the analysis of the basic structure, performance, application effe...
beh Industrial Control Electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号