CMOS COMPATIBLE WITH TRI-STATE OUTPUT

SM1100C SERIES
n
n
n
CMOS COMPATIBLE
WITH
TRI−STATE OUTPUT
SURFACE MOUNT OSCILLATORS IN PLASTIC PACKAGE
LAND PATTERN COMPATIBLE TO OUR ENTIRE SM1100X SERIES AND EPSON SG615
STANDARD SPECIFICATIONS:
Frequency Range
Frequency Stability over Operating
Temperature Range
Operating Temperature Range
Operable Supply Voltage (Vcc)
Symmetry (Duty Cycle)
(See next page for definition.)
Input Current (Icc) & Rise and Fall Time
(Tr & Tf) & Jitter
Logic “1” & Logic “0” (See next page)
Output Load
Tri-state Output
Packaging (see page R1, Figure 2)
1.000 MHz – 50.000 MHz (Consult factory for specific available frequencies)
±
50 PPM is standard, but
±
25 PPM is also available for certain frequencies.
0 - 70°C is standard, but can be extended to
−40
to +85°C for
certain frequencies
1.000 MHz – 30.000 MHz
30.001 MHz – 50.000 MHz
SM1100CY
SM1100CY
SM1100CV
5 Volt
±
10% or 3.3 Volt
±
10%
5 Volt
±
10% only
3.3 Volt
±
10% only
40/60 - 60/40% is standard, but 45/55% symmetry at 50% of Vcc
is also available.
Depends on frequency and output load. See next page.
90% of Vcc MIN.; 10% of Vcc MAX.
15 pF is standard. Contact factory for heavier loads.
Normal output when pin #1 is open (no connection);
Normal output when pin #1 is at logic “1”;
High-Impedance Output when pin #1 is at logic “0”.
24 mm tape, 330 mm reel: 1000 parts per reel.
For quantities <250: 23 parts per tube.
PART NUMBERING GUIDE:
n
The Pletronics part number for an SM1100C series oscillator consists of the following 3 elements:
1.
Overall Frequency Stability over Operating Temperature Range:
SM1145C:
±
50 PPM;
SM1144C:
±
25 PPM
Optional Alphabet Designator for Special Requirement:
SM1100CY: standard specifications;
SM1145CE: operating temperature range of -40 to +85°C;
SM1100CS: 45/55% symmetry at 50% of Vcc;
SM1100CV: operates at Vcc = 3.3V (only needed for over 30.000MHz)
(There are other alphabet designators not listed here.)
Frequency of Operation in MHz
2.
3.
EXAMPLES: SM1145CV-50.000 MHz; SM1145CS-10.000 MHz; SM1144CE-50.000 MHz
n
When customer’s requirements are non-standard, a special engineering part number will be assigned.
(continued)
Telephone: (425) 776-1880, Fax: (425) 776-2760, e-mail: ple-sales@pletronics.com
O7A

SM1100CS Related Products

SM1100CS SM1100C SM1100CV SM1100CY SM1144C SM1144CE SM1145C SM1145CE SM1145CS SM1145CV
Description CMOS COMPATIBLE WITH TRI-STATE OUTPUT CMOS COMPATIBLE WITH TRI-STATE OUTPUT CMOS COMPATIBLE WITH TRI-STATE OUTPUT CMOS COMPATIBLE WITH TRI-STATE OUTPUT CMOS COMPATIBLE WITH TRI-STATE OUTPUT CMOS COMPATIBLE WITH TRI-STATE OUTPUT CMOS COMPATIBLE WITH TRI-STATE OUTPUT CMOS COMPATIBLE WITH TRI-STATE OUTPUT CMOS COMPATIBLE WITH TRI-STATE OUTPUT CMOS COMPATIBLE WITH TRI-STATE OUTPUT
MSP430F5529 general I/O port settings
[size=4]Learn I/O first. I/O operation is the most basic, and these registers must be firmly mastered. The difficulty of MSP430 is that it has a large number of registers that need to be set. Although...
火辣西米秀 Microcontroller MCU
5 production processes that must be considered before PCB layout
[align=left][color=rgb(51, 51, 51)]When drawing PCB, we need to consider several issues clearly[/color][/align][list] [*][align=left]Single-layer board or double-layer board? [/align] [*][align=left]I...
okhxyyo PCB Design
Selling Zedboard Zynq7020 development board
[i=s]This post was last edited by fjjjnk1234 on 2020-10-18 11:30[/i]Zedboard development board, compatible with the official Zedboard Chip model: Zynq-7020-CLG 484-2I Condition: 95% new or above Acces...
fjjjnk1234 Buy&Sell
I have to say that the old technology I have been exposed to since 2008 was still blocked at that time.
1-3. Input and output matching circuit The purpose of the matching circuit is to choose a way of acceptance. For those transistors that want to provide greater gain, the way is to accept and output it...
btty038 RF/Wirelessly
Calibration of medical devices
Calibration of medical devices 1. Thermometer calibration - use black body furnace + constant temperature water bath to calibrate two points 2. Sphygmomanometer calibration - using BP pump sphygmomano...
QWE4562009 Test/Measurement
Doesn't high input impedance mean high loss? Why does sampling require high input impedance? Low output impedance, such as running...
Doesn't high input impedance mean high loss? Why does sampling require high input impedance? Low output impedance, such as an op amp circuit...
QWE4562009 Integrated technical exchanges

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号