HVP200-491B

Description
UNIVERSAL INPUT HARMONIC CORRECTION AC-DC OPEN FRAME AND ACTIVE CURRENT SHARING MULTI-OUTPUT 200 WATTS INTERNAL SWITCHING POWER SUPPLIES
File Size375KB,2 Pages
ManufacturerHitron
Websitehttp://www.hitron-e.com/
Download Datasheet View All

HVP200-491B Overview

UNIVERSAL INPUT HARMONIC CORRECTION AC-DC OPEN FRAME AND ACTIVE CURRENT SHARING MULTI-OUTPUT 200 WATTS INTERNAL SWITCHING POWER SUPPLIES

H HiTRON
UNIVERSAL INPUT HARMONIC CORRECTION AC-DC OPEN FRAME
AND ACTIVE CURRENT SHARING MULTI-OUTPUT 200 WATTS
INTERNAL SWITCHING POWER SUPPLIES HVP200 SERIES
FEATURES:
ACCOMMODATE UNIVERSAL AC SOURCES
MEET IEC 61000-3-2 HARMONIC CORRECTION
THIRD-WIRE LOADING SHARING
MEET UNIVERSAL SAFETY STANDARDS
EMI MEET CISPR PUB.22 CLASS B
+5V STAND-BY GREEN POWER
CE MARKING COMPLIANCE
SPECIFICATION
INPUT SPECIFICATION
Input Voltage:
Typ. 90-264Vac with PFC.
Input Connector:
Molex #5273 V-M connector.
Input Frequency:
47-63Hz.
Inrush Current:
Typ. 33A @230Vac.
Input Current:
2.25A @115Vac, 1.0 A@230Vac.
Dielectric Withstand:
Meet IEC 60950-1.
EMI:
Meet CISPR PUB.22 Class B.
Hold-up Time:
18mS @115Vac & 230Vac.
Power Fail Signal:
Installed.
DC OK Signal:
Installed in VO1 & VO2.
Power Factor Correction:
Meet Harmonic Correction
per IEC 61000-3-2 PF typ. 0.97-0.99.
Remote Inhibit:
Installed. Enable active high.
Over Temperature Protection:
Thermostat @ 95°C.
Earth Leakage:
Less than 0.75mA.
OUTPUT SPECIFICATION
Output Voltage:
See Ratings Chart.
Output Current:
See Ratings Chart.
Output Connector:
Molex #5273 V-M connector.
Output Wattage:
Convection 150 watts.
With 30 cfm forced air 200W.
Line Regulation:
Typ. 0.1%.
Load Regulation:
Main O/P VO1: Typ. ±1.0%.
Aux. O/P VO2: Typ. ±1.0%. (Magnetic Amp).
Aux. O/P VO3,4,5: Typ. ±2-3.0%. (P.R.).
Stand-By Green Power:
+5V/50mA available.
Noise & Ripple:
Typ. 1.0% peak to peak.
OVP:
Available at VO1 & VO2.
Remote Sense:
Installed in VO1 & VO2.
Adjustability:
Available at VO1 & VO2.
Load Sharing:
Active current sharing circuit at VO1.
Overload Protection (OLP):
Fully protected against output
overload and short circuit.
Consult the factory for OLP setting.
Operating Temperature:
0 to +50°C under forced air flow
for full load.
Storage Temperature:
-20 to +85°C.
Temperature Coefficient:
Typ. ±0.04%/ °C.
Cooling:
30 cfm air flow is required to deliver
the full power 200W.
Construction:
U-bracket construction format.
GENERAL SPECIFICATION
Efficiency:
Typ. 65-70%.
Switching Frequency:
Fixed frequency at 70K Hz.
Circuit Topology:
PWM fixed-frequency forward circuit.
Transient Response:
Output voltage returns in less than
3mS following a 25% load change.
Safety Standard:
UL 60950-1/EN 60950-1 Class I.
Power Density:
3.0 Watts / Cubic Inch.
Note: Due to requests in market and advances in technology, specifications subject to change without notification.
For the details of safety approval, please consult the factory.
-53-

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号