Standard Frequencies: 10; 12.8; 19.2; 20; 26; 30.72 Mhz
•
•
•
•
•
Applications
Base stations
Test equipment
Synthesizers
Military communication equipment
Digital Switching
Performance Specifications
Frequency Stabilities
1
(SC-Cut Crystal-Option - 10 to 40 MHz)
Parameter
vs. operating temperature range
(referenced to +25°C)
Initial tolerance
vs. supply voltage change
vs. load change
vs. aging / day
vs. aging / day
vs. aging / year
vs. aging / year
Holdover
start up time
Warm-up time
5
minutes
to ±100ppb of final frequency (1 hour
reading) @ +25°C
Min
-10
-10
-0.2
-5
-5
-0.5
-1
-60
-100
Typical
Max
+10
+10
+0.2
+5
+5
+0.5
+1
+60
+100
Units
ppb
ppb
ppm
ppb
ppb
ppb
ppb
ppb
ppb
Condition
-20 to +70°C
-40 to +85°C
at time of shipment, nominal EFC
V
S
±5% static
Load ±5% static
≤10 Mhz after 30 days of operation
> 10 Mhz after 30 days of operation
≤ 10 Mhz after 30 days of operation
> 10 Mhz after 30 days of operation
Page 1 of 8
Vectron International • 267 Lowell Road, Hudson Suite 102, NH 03051 • Tel: 1-88-VECTRON-1 • http://www.vectron.com
Performance Specifications
Supply Voltage (Vs)
Parameter
Supply voltage (standard)
Min
3.135
4.75
Typical
3.3
5.0
Max
3.465
5.25
3.1
1.5
Units
VDC
VDC
Watts
Watts
Condition
Power consumption
during warm-up
steady state @ +25°C
RF Output
Signal [standard]
Load
Signal Level (Vol)
Signal Level (Vol)
Signal Level (Voh)
Signal Level (Voh)
Duty Cycle
Rise time
Fall time
Signal
Load
Output Power @3,3V
Putput Power @ 5.0V
Harmonics
Tuning Range
±0.8
Linearity
Tuning Slope
Control Voltage Range
modulation
Reference Voltage Output (Vref )
Reference Voltage
2.75
3.92
2.8
4.0
-80
-110
-138
-148
-152
-90
-120
-140
-148
-152
2.85
4.08
-70
-105
-130
-140
-145
-80
-110
-135
-145
-145
10
Handling & Processing Note
VDC
VDC
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
g
with Vs = 3.3 VDC
with Vs = 5.0 VDC
1 Hz
10 Hz
100 Hz
1 kHz
10 kHz
1 Hz
10 Hz
100 Hz
1 kHz
10 kHz
0.0
0.0
1.4
2.0
10%
Positive
2.8
4.0
VDC
VDC
with Vs=3.3V
with Vs=5.0V
2
5
50
5
8
8
11
-30
Fixed OCXO; No adjust
±2.4
ppm
with SC cut crystal
Sine Wave
Ω
dBm
dBm
dBm
50 Ω load
50 Ω load
50 Ω load
2.4
3.5
45
55
5
5
%
ns
ns
15
0.4
0.5
VDC
HCMOS
pF
VDC
with Vs=3.3V and 15pF Load
with Vs=5.0V & 12V and 15pF Load
with Vs=3.3V and 15pF Load
with Vs=5.0V & 12V and 15pF Load
@ (Voh-Vol)/2
Frequency Tuning (EFC)
Opti-
on
5
@
30.72MHz
with SC
Cut
@ 20MHz
with SC
Cut
Additional Parameters
Phase Noise
3
Phase Noise
3
Weight
Processing & Packing
Page 2 of 8
Vectron International • 267 Lowell Road, Hudson Suite 102, NH 03051 • Tel: 1-88-VECTRON-1 • http://www.vectron.com
Absolute Maximum Ratings
supply voltage (Vs)
Output Load
Operable Temperature Range
Storage Temperature Range
-45
-45
5.5
50
+85
+85
V
pF
°C
°C
with Vs=3.3 & 5.0 VDC
Outline Drawing / Enclosure
OX-220
Height “H”
12.1
8.5
cover material
plastic
plastic
Pin Connections
1
2
3
4
5
6
7
Electronic Frequency Control Input (EFC)
Reference Voltage output
Supply Voltage Input (Vs)
RF Output
Oven Alarm
N.C or Option (must remain un connected)
Ground (Case)
Dimensions in mm
Page 3 of 8
Vectron International • 267 Lowell Road, Hudson Suite 102, NH 03051 • Tel: 1-88-VECTRON-1 • http://www.vectron.com
Standard Shipping Method (OX-220 / OX -221)
Enclosure Type
OX-2201 (12.1mm)
OX-2206 (8.5mm)
Tape Width W (mm)
44
44
Quantity per meter
37.5
37.5
Quantity per reel
175
250
Dimension P
28
28
Recommended Reflow Profile
IPC/JEDEC J-STD-020 (latest revision)
Additional Information:
This SMD oscillator has been designed for pick and place reflow soldering.
SMD oscillators must be on the top side of the PCB during the reflow process.
Additional Environmental Conditions
Parameter
Rapid temperature
changes
Vibration
Shock
Solderability
Solvent resistance
ESD
Moisture Sensit.
RoHS compliance
Washable
Description
MIL-883-1010 Cond B 1000 cycles -55/125C
MIL-STD-883 Meth 2007 Cond A 20G 20-2000Hz 4x in each 3axis 4 min
Mech.Shock MIL-STD-202 Meth 213 Cond.C 100G 6ms 6 shocks in each direction
J_STD_002C Cond A, Through hole device/ Cond. B, SMD 255C (diving time
50,5sec.) Dip+Look with 8h damp pre-treatment: solder wetting >95%
MIL-STD-883 Meth 2015 Solv. 1,3,4
HBM JESD22-A114-F Class 1C 10* 1000V
Level 1 JESD22-A113-B
100% RoHS 6 compliant
non-washable device
Note:
All temperatures refer to topside of the package, measured on the package body surface.
Page 4 of 8
Vectron International • 267 Lowell Road, Hudson Suite 102, NH 03051 • Tel: 1-88-VECTRON-1 • http://www.vectron.com
Ordering Information
OX - 220 1 - D A E - 108 0 - 10M0000000
Product Family
OX: OCXO
Frequency
Package
SMD version: 220
Frequency Control
0: No Tuning
1: ±0.8 to ±2.4ppm
Stability Code
108: ±10ppb
Supply Voltage
D: 5V
E: 3.3V
RF Output Code
A: HCMOS
E: Sinewave
Height
1: 12.1 mm
6: 8.5 mm
Temperature Range
E: -40°C to +85°C
J: -20°C to +70°C
Notes:
1. Contact factory for improved stabilities or additional product options. Not all options and codes are available at all
frequencies.
2. Unless other stated all values are valid after warm-up time and refer to typical conditions for supply voltage, frequency
control voltage, load, temperature (25°C).
3. Phase noise degrades with increasing output frequency.
4. Subject to technical modification.
5. Contact factory for availability.
For Additional Information, Please Contact
USA:
Vectron International
267 Lowell Road
Suite 102
Hudson, NH 03051
Tel: 1.888.328.7661
Fax: 1.888.329.8328
Europe:
Vectron International
Landstrasse, D-74924
Neckarbischofsheim, Germany
Tel: +49 (0) 7268.801.100
Fax: +49 (0) 7268.801.282
Asia:
Vectron International
68 Yin Cheng Road(C), 22nd Floor
One LuJiaZui
Pudong, Shanghai 200120, China
Tel: +86 21 6194 6886
Fax: +86 21 6194 6699
Disclaimer
Vectron International reserves the right to make changes to the product(s) and or information contained herein without notice. No liability is assumed as a result of their use or application.
No rights under any patent accompany the sale of any such product(s) or information.
Rev 18 Feb 2014
Page 8 of 8
Vectron International • 267 Lowell Road, Hudson Suite 102, NH 03051 • Tel: 1-88-VECTRON-1 • http://www.vectron.com