TLGG-LR-LTA205-TG-BR/6V

Description
Rocker Switch, SPST, Latched, Wire Terminal, Rocker Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size189KB,2 Pages
ManufacturerCarling Technologies
Environmental Compliance  
Download Datasheet Parametric View All

TLGG-LR-LTA205-TG-BR/6V Overview

Rocker Switch, SPST, Latched, Wire Terminal, Rocker Actuator, Panel Mount

TLGG-LR-LTA205-TG-BR/6V Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerCarling Technologies
Reach Compliance Codecompliant
ECCN codeEAR99
Actuator typeROCKER
body width25.24 mm
body height20.62 mm
Body length or diameter28.44 mm
Contact (AC) maximum rated R load15A@125VAC
Maximum contact current (AC)15 A
Maximum contact voltage (AC)125 V
Electrical life50000 Cycle(s)
illuminationGREEN LAMP
Manufacturer's serial numberTLG
Installation featuresPANEL MOUNT
Maximum operating temperature66 °C
Minimum operating temperature
surface mountNO
Switch actionLATCHED
switch functionSPST
Switch typeROCKER SWITCH
Termination typeWIRE
Carling
Technologies
TLG-Series Rocker Switches
TLG-Series Rocker Switches
The TLG-Series Mini Tippette snap-in rocker switches are
single pole, rocker or paddle actuated with an adjacent indi-
cator light. These single-actuator-switches are AC rated to
20 amps and are also suitable for low voltage DC applica-
tions, in a wide range of markets including Appliance,
HVAC, Food service and Transportation.
Dielectric Strength
UL/CSA:
1000V - live to dead metal parts
Electrical Life
50,000 cycles- maintained
25,000 cycles- momentary
Mechanical Life
100,000 cycles
Operating Temperature
32°F to 150°F (0°C to +65.6°C)
.069[1.75] DIA
.156[1.75] DIA
.055[1.75] DIA
6.000[152.40]
.375[9.52]
.250[6.35]
.500[12.70]
.187[4.74]
INTEGRATED WIRE LEAD
(no exposed conductors)
1.155[29.33]
.390[9.90]
.050[1.27]
1.240[31.49]
.250[6.35]
.250[6.35]
.250 TAB (Q.C.)
SOLDER LUG
.187 TAB (Q.C.)
TERMINAL TYPE
.220[5.59]
.812[20.62]
.275[6.98]
.375[9.52]
1.000[25.40]
1.120[28.44]
PADDLE
SHORT PADDLE
MOUNTING HOLE
Panel Thickness:
.020[.508] min. to
.250[6.35] max.
.520[13.20]
1.125[28.57]
.994[25.24]
TLG G
-
D R
-
TA 20 1
-
T B
-
B
1
Base Part Number
2
Circuit
3
Lens
Design
4
Lens Color
5
Basic Switch
Number
6
Rating
7
Termination
/ Function
8
Actuator
Style
9
Actuator
Color
10
Base Color
/
125N
11
Lens Color
12
Lamp Voltage
1 BASE PART NUMBER: SERIES
TLG
Single Pole with adjacent Indicator Light
2 CIRCUIT
1
See Circuit Designation Chart Page 17.
3 LENS DESIGN
D
diamond
L
long Line
4 LENS COLOR
A
amber
C
clear
7 TERMINATION/FUNCTION
solder lug
.250 tab QC .187 tab QC
ON-NONE-OFF
0
1
3
(ON)-NONE-OFF
A
B
D
ON-NONE-(OFF)
L
M
R
ON-NONE-ON
0
1
3
ON-NONE-(ON)
A
B
D
ON-OFF-ON
0
1
3
8 ACTUATOR STYLE
P
paddle
PS
T
wire leads
5
F
T
5
F
5
short paddle
rocker
G
R
green
red
W
white
5 BASIC SWITCH NUMBER
4
TA
ON-NONE-OFF
TB
ON-NONE-ON
9 ACTUATOR COLOR
3
unlighted
B
black
W
white
TC
ON-OFF-ON
LTA
OFF-NONE-ON, lighted
10 BASE COLOR
3
B
black
11 LENS COLOR
2,4
A
amber
C
clear
12 LAMP VOLTAGE
incandescent
6V
6 volt
12V
12 volt
18V
18 volt
24V
24 volt
28V
28 volt
lighted
2
A
amber
C
clear
G
green
LU
blue
R
red
6 RATING
10
5A 250VAC, 10A 125VAC, 1/2HP 125-250VAC
11
5A 250VAC, 10A 125VAC, 5A 125VAC L
20
10A 250VAC, 15A 125VAC, 3/4HP 125-250VAC
21
10A 250VAC, 15A 125VAC
22
10A 250VAC, 15A 125VAC, 20A 125-250VAC H, 3/4HP 125-250VAC
NOTES:
Imprinting is available. Consult factory.
Panel Cut-Out Recommendations: For sheet metal panels, switch must enter panel in same direction
as the punch. (Burr on bottom.) Test cut hole in actual material.
1 Available with circuits G, H, I, J, K.
2 Neon lamps (125V or 250V) not recommended with green or blue actuators and lenses.
3 Custom colors are available. Consult factory.
4 Specify lens color only if Basic Switch Number is LTA (lighted). If not, leave blank.
( ) Indicates momentary function.
W
white
G
LU
green
blue
R
W
red
white
neon
2
125N
125 volt neon
250N
250 volt neon
16
www.carlingtech.com
Free review: Domestic RISC-V Linux board Fang Xingguang VisionFive
Evaluation kit: Fang Starlight VisionFive (5 sets in total, valued at 1100) Kit source: Siafan Technology (StarFive)I have warmed up for you in the forum before, The domestic RISC-V Linux VisionFive b...
EEWORLD社区 Domestic Chip Exchange
How to configure DM368 to make the output image horizontally mirrored when using sensor image acquisition
How to configure DM368 to make the output image horizontally mirrored when using sensor image acquisition...
huangyunxiang DSP and ARM Processors
Chat: How does your company control technical documents?
How are the source files of product schematics and PCB diagrams, and the source codes of embedded programs and host computer programs managed and controlled in the company? My previous unit used an in...
mmmllb Talking about work
[ModelSim FAQ] Can't launch the ModelSim-Altera software
Error message: Error: Can'tlaunch the ModelSim-Altera software -- the path to the location of theexecutables for the ModelSim-Altera software were not specified or theexecutables were not found at spe...
小梅哥 Altera SoC
Please give me some advice!!!
Please take a look at what error occurred during the process of exporting the schematic diagram to PCB....
ABC123! PCB Design
Can the vehicle gateway be integrated into other modules?
Dear experts, I have a question. Our company is currently preparing to use AUTOSAR network management. We have been planning to use an independent gateway, but the leaders asked us to analyze whether ...
gumptao Automotive Electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号