EEWORLDEEWORLDEEWORLD

Part Number

Search

6QDPS-064-39.37-TEU-TBL-1-F

Description
Interconnection Device, ROHS COMPLIANT
CategoryThe connector    The connector   
File Size655KB,1 Pages
ManufacturerSAMTEC
Websitehttp://www.samtec.com/
Environmental Compliance  
Download Datasheet Parametric View All

6QDPS-064-39.37-TEU-TBL-1-F Overview

Interconnection Device, ROHS COMPLIANT

6QDPS-064-39.37-TEU-TBL-1-F Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerSAMTEC
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
Connector typeINTERCONNECTION DEVICE
F-209 SUPPLEMENT
6QDP–032–06.0–STR–TTR–2
6QDPS–016–06.0–STR–TEU–3–B
0,635
mm
TWINAX CABLES
SPECIFICATIONS
For complete specifications see
www.samtec.com?6QDPS or
www.samtec.com?6QDP
Cable:
30 AWG
Eye Speed™ MS
twinax micro ribbon
(6QDPS)
Signal Routing:
100Ω Differential
Cable Bending Radius:
(11,11mm) 7/16" min
Plating:
Au over 50µ" (1,27µm) Ni
Current Rating:
1 A max
Propagation Delay:
4.67 nsec/meter
Operating Temp Range:
-20°C to +90°C
Skew (pair-to-pair):
<10 ps/ft
Skew (within a pair):
<5 ps/ft
EMI Performance:
FCC Class A
RoHS Compliant:
Yes
6QDPS, 6QDP
SERIES
Increased
Insertion Depth
Mates with:
QMSS-DP, QFSS-DP,
QMS-DP, QFS-DP
APPLICATIONS
Optional
Shielding
30 AWG
Eye Speed ™ MS
twinax ribbon cable
Cable
Length
6" (152,4mm)
12" (304,8mm)
19.68" (0,5m)
39.37" (1m)
Rated @ -3dB Insertion Loss
6QDPS
4.0 GHz / 8.0 Gbps
3.72 GHz / 7.44 Gbps
1.38 GHz / 2.76 Gbps
1.04 GHz / 2.08 Gbps
Differential
Pair routing
APPLICATIONS
(12,70)
.500
TYPE
NO. OF
PAIRS
WIRE
LENGTH
END
NO. 1
END
NO. 2
WIRING
OPTION
SCREW
OPTION
(24,13)
.950
(15,11)
.595
–“XX.X”
6QDPS
= Shielded mates
with QMSS-DP/
QFSS-DP
Processing conditions will
affect mated height.
END TO END
Surface Mount to
Surface Mount
Surface Mount to
Edge Mount (Terminal)
Surface Mount to
Edge Mount (Socket)
Edge Mount (Terminal) to
Edge Mount (Terminal)
Edge Mount (Terminal) to
Edge Mount (Socket)
Edge Mount (Socket) to
Edge Mount (Socket)
L
(23,88)
.940
(21,08)
.830
(20,35)
.801
(18,29)
.720
(17,55)
.691
(16,81)
.662
6QDP
= Unshielded
mates with
QMS-DP/QFS-DP
–016,
–032,
–048,
–064
= Wire Length
in Inches
(95,3mm) 03.8"
minimum
Specify
END
ASSEMBLIES
from chart
–1
= Pin 1 to
Pin 1
Leave
blank for
no Screw
Option
–2
= Pin 1 to
Pin 2
–F
= End No. 1
SURFACE MOUNT
ASSEMBLY
END 1
064
001
END 2
064
001
–3
= Pin 1 to
Second
Last Pin
–S
= End No. 2
OAL = Wire Length +
L
Wire Length
±(1,27) .050
Note:
Cable lengths longer than
40.00" (1 meter) are not
supported with S.I. test data.
Note:
Verify part number and correct
wiring scheme with Samtec’s
Interactive Cable Builder at
www.samtec.com/cable_
builder/pitch.asp
Note:
This Series is non-standard,
non-returnable.
–TTR
=Terminal,
Top,
Notch
Right
–TTL
=
Terminal,
Top,
Notch
Left
–TBR
=
Terminal,
Bottom,
Notch
Right
–TBL
=
Terminal,
Bottom,
Notch
Left
–STR
=
Socket,
001
Top,
Notch
Right,
–STL
=
Socket,
064
Top,
Notch
Left
–SBR
=
Socket,
Bottom,
Notch
Right
001
–SBL
=
Socket,
Bottom,
Notch
Left
064
–B
= Both
Ends
–4
064
001
001
064
064
001
= Pin 1 to
Last Pin
WIRING REQUIREMENTS
WIRING
END OPTIONS
OPTION
1 or 2
TTR, TBL, STL, SBR, TEU to
TTR, TBL, STL, SBR, TED
or
TTL, TBR, STR, SBL, TED to
TTL, TBR, STR, SBL, TEU
TTL, TBR, STR, SBL, TED to
TTR, TBL, STL, SBR, TED
or
TTR, TBL, STL, SBR, TEU to
TTL, TBR, STR, SBL, TEU
001
064
EDGE MOUNT
ASSEMBLY
(7,47)
.294
–TEU
=Terminal,
Edge,
Notch
Up
END 1
064
END 2
3 or 4
001
END NO. 1
(-TTL SHOWN)
END NO. 2
(-STR SHOWN)
–TED
=Terminal,
Edge,
Notch
Down
001
064
WWW.SAMTEC.COM
Theoretical basis of the movie "The Wandering Earth"
The Roche limit is roughly equal to the sum of the radii of the two bodies, which means that even if the Earth is to break, it will be "broken" by falling into Jupiter rather than being torn into piec...
PowerAnts Talking
Satellite Internet in One Picture
...
btty038 RF/Wirelessly
cc254x cc2640 WeChat access airsync-broadcast data
1. Experimental purpose:Modify ble broadcast data to comply with airsync protocol2. Experimental environment:Hardware platform: cc2540, cc2541, cc2640Protocol stack version: The broadcast data of each...
Jacktang Microcontroller MCU
Summary of issues in design and installation of grounding devices
1. The grounding device should be made of steel, and the conductor cross-section of the grounding device should meet the requirements of thermal stability and mechanical strength.  2. The buried depth...
fish001 Analogue and Mixed Signal
Common C language errors in MCU development
When developing microcontrollers, there are often some insignificant problems. These problems are actually very basic C language knowledge points and some small details. But precisely because they are...
Aguilera Microcontroller MCU
How to load BIT into FPGA via network port?
I saw someone use the network port to load bits into FPGA, and I want to know what the principle is? Is it implemented by program or circuit?...
928083047 FPGA/CPLD

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号