Communications, control systems, medical, instrumentation, defense and aerospace.
For details on proper operation please refer to the:
Design Guide & Applications Manual for Maxi, Mini, Micro Family.
Absolute Maximum Ratings
Product Overview
These DC-DC converter modules use
advanced power processing, control and
packaging technologies to provide the
performance, flexibility, reliability and cost
effectiveness of a mature power component.
High frequency ZCS/ZVS switching provides
high power density with low noise and
high efficiency.
Part Numbering
e.g. V150A24C500BL
V1 5 0 A
Product Grade Temperatures (°C)
Grade
Operating
Storage
E
=
- 10 to +100
- 20 to +125
C
=
- 20 to +100
- 40 to +125
T
=
- 40 to +100
- 40 to +125
H
=
- 40 to +100
- 55 to +125
M
=
- 55 to +100
- 65 to +125
B
Output Power
V
OUT
P
OUT
3.3V
200W, 264W
5V
300W, 400W
8V
300W, 400W
12V
400W, 500W
15V
400W, 500W
24V
400W, 500W
28V
400W, 500W
36V
400W, 500W
48V
400W, 500W
Pin Style
Finish
Blank:
Short
Tin/Lead
L:
Long
Tin/Lead
S:
Short ModuMate
Gold
N:
Long ModuMate
Gold
F:
Short RoHS
Gold
G:
Long RoHS
Gold
K:
Extra Long RoHS
Gold
Baseplate
Blank:
Slotted
2:
Threaded
3:
Through-hole
Output Voltage
3V 3
= 3.3V
5
= 5V
8
= 8V
12
= 12V
15
= 15V
24
= 24V
28
= 28V
36
= 36V
48
= 48V
150V Maxi Family
Page 1 of 13
Rev 2.7
02/2017
vicorpower.com
800 927.9474
150V Input
Module Family Electrical Characteristics
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified.
All temperatures refer to the operating temperature at the center of the baseplate.
MODULE INPUT SPECIFICATIONS
Parameter
Operating input voltage
Input surge withstand
Undervoltage turn-on
Undervoltage turn-off
Overvoltage turn-off/on
Disabled input current
81.9
201.9
97.0
84.9
210
220
1.1
Min
100
Typ
150
Max
200
250
99.0
Unit
V
DC
V
DC
V
DC
V
DC
V
DC
mA
PC pin low
<100ms
Notes
MODULE OUTPUT SPECIFICATIONS
Parameter
Output voltage setpoint
Line regulation
Temperature regulation
Power sharing accuracy
Programming range
10
±0.02
±0.002
±2
Min
Typ
Max
±1
±0.20
±0.005
±5
110
Unit
%
%
% / °C
%
%
Notes
Of nominal output voltage. Nominal input; full load; 25°C
Low line to high line; full load
Over operating temperature range
10 to 100% of full load
Of nominal output voltage. For trimming below 90%
of nominal, a minimum load of 10% of maximum
rated power may be required.
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
+OUT to –OUT, +Sense to –OUT — Absolute Maximum Ratings
3.3V
5V
8V
12V
15V
24V
28V
36V
48V
–0.5 to 4.7
–0.5 to 7.0
–0.5 to 10.9
–0.5 to 16.1
–0.5 to 20.0
–0.5 to 31.7
–0.5 to 36.9
–0.5 to 47.4
–0.5 to 62.9
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
Note:
The permissible load current must never be exceeded during normal, abnormal or test conditions. For additional output related application
information, please refer to output connections on page 8.
THERMAL RESISTANCE AND CAPACITY
Parameter
Baseplate to sink; flat, greased surface
Baseplate to sink; thermal pad (P/N 20263)
Baseplate to ambient
Baseplate to ambient; 1000LFM
Thermal capacity
Min
Typ
0.08
0.07
4.9
1.1
165
Max
Unit
°C/Watt
°C/Watt
°C/Watt
°C/Watt
Watt-sec/°C
150V Maxi Family
Page 2 of 13
Rev 2.7
02/2017
vicorpower.com
800 927.9474
150V Input
Module Family Electrical Characteristics (Cont.)
MODULE CONTROL SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Notes
Primary Side (PC = Primary Control; PR = Parallel)
PC bias voltage
current limit
PC module disable
PC module enable delay
PC module alarm
PC resistance
PR emitter amplitude
PR emitter current
PR receiver impedance
PR receiver threshold
PR drive capability
Secondary Side (SC = Secondary Control)
SC bandgap voltage
SC resistance
SC capacitance
SC module alarm
1.21
990
1.23
1000
0.033
0
1.25
1010
V
DC
Ω
µF
V
DC
With open trim; referenced to –Sense. See Fig. 7
Referenced to –Sense
0.9
5.7
150
375
2.4
500
2.5
625
2.6
12
1.0
5.9
5.50
1.5
2.3
5.75
2.1
2.6
4
6.00
3.0
2.9
7
0.5
1.1
6.1
V
DC
mA
V
DC
ms
Vavg
MΩ
Volts
mA
Ω
Volts
modules
25°C
Minimum pulse width: 20ns
Without PR buffer amplifier
UV, OV, OT, module fault. See Figs. 3 and 5
See Fig. 3, converter off or fault mode
PR load >30Ω, <30pF
PC current = 1.0mA
PC voltage = 5.5V
During normal operation
Switch must be able to sink
≥4mA.
See Fig. 2
MODULE GENERAL SPECIFICATIONS
Parameter
Remote sense (total drop)
Isolation test voltage (IN to OUT)*
Isolation test voltage (IN to base)*
Isolation test voltage (OUT to base)*
Isolation resistance
Weight (E, C, T grade)
Weight (H, M grade)
6.5
(184.3)
7.4
(209.3)
100
3000
1500
500
10
7.3
(207.5)
8.2
(232.5)
115
cURus, cTÜVus, CE
8.1
(230.7)
9.0
(255.7)
Min
Typ
Max
0.5
Unit
V
DC
V
RMS
V
RMS
V
RMS
MΩ
ounces
(grams)
ounces
(grams)
°C
See Figs. 3 and 5. Do not operate coverter >100°C.
UL60950-1, EN60950-1, CSA60950-1, IEC60950-1.
With appropriate fuse in series with the +Input
Notes
0.25V per leg (sense leads must be connected to
respective, output terminals)
Complies with reinforced insulation requirements
Complies with basic insulation requirements
Complies with operational insulation requirements
IN to OUT, IN to baseplate, OUT to baseplate
Temperature limiting
Agency approvals
* Isolation test voltage, 1 minute or less.
Note:
Specifications are subject to change without notice.
150V Maxi Family
Page 3 of 13
Rev 2.7
02/2017
vicorpower.com
800 927.9474
150V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS
3.3V
OUT
, 264W (e.g. V150A3V3C264BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load Current
Current limit
Short circuit current
Min
78
4.14
Typ
80.8
80
4.3
7
±0.02
92
92
Max
100
4.46
8.3
±0.2
80
108
108
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
81.6
56
3.3V
OUT
, 200W (e.g. V150A3V3C200BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load Current
Current limit
Short circuit current
Min
81.2
4.14
Typ
82
164
4.3
6.4
±0.02
69.7
69.7
Max
205
4.46
7.5
±0.2
60.6
81.9
81.9
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
61.8
42.4
5V
OUT
, 400W (e.g. V150A5C400BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load Current
Current limit
Short circuit current
Min
83.9
6.03
Typ
84.9
75
6.25
11
±0.02
92
92
Max
94
6.47
12.9
±0.2
80
108
108
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
81.6
56
5V
OUT
, 300W (e.g. V150A5C300BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load Current
Current limit
Short circuit current
Min
83.6
6.03
Typ
84.9
150
6.25
7.7
±0.02
69
69
Max
188
6.47
10
±0.2
60
81
81
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
61.2
42
8V
OUT
, 400W (e.g. V150A8C400BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load Current
Current limit
Short circuit current
Min
83
9.36
Typ
84.2
320
9.7
11.4
±0.02
57.5
57.5
Max
400
10.1
12.5
±0.2
50
67.5
67.5
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
51
35
150V Maxi Family
Page 4 of 13
Rev 2.7
02/2017
vicorpower.com
800 927.9474
150V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)
8V
OUT
, 300W (e.g. V150A8C300BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Output Current
Current limit
Short circuit current
Min
85
9.36
Typ
86.2
220
9.7
7.9
±0.02
43.1
43.1
Max
275
10.1
9.5
±0.2
37.5
50.7
50.7
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
38.2
26.2
12V
OUT
, 500W (e.g. V150A12C500BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load Current
Current limit
Short circuit current
Min
86.2
13.7
Typ
87.6
385
14.3
11.3
±0.02
48
48
Max
482
14.9
12.3
±0.2
41.67
56.3
56.3
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
42.5
29.1
12V
OUT
, 400W (e.g. V150A12C400BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load Current
Current limit
Short circuit current
Min
86.6
13.7
Typ
87.5
264
14.3
11
±0.02
38.3
38.3
Max
330
14.9
12.9
±0.2
33.33
45
45
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
33.9
23.3
15V
OUT
, 500W (e.g. V150A15C500BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load Current
Current limit
Short circuit current
Min
85
17.1
Typ
86.3
280
17.8
13.4
±0.02
38.3
38.3
Max
350
18.5
15
±0.2
33.33
45
45
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
33.9
23.3
15V
OUT
, 400W (e.g. V150A15C400BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load Current
Current limit
Short circuit current
Min
85
17.1
Typ
88.6
180
17.8
11.5
±0.02
30.7
30.7
Max
225
18.5
12.5
±0.2
26.67
36.1
36.1
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
[b]MY-IMX6-EK140P Linux-4.1.15 Test Manual[/b] From Mingyuan Zhirui's wiki Directory [[url=http://wiki.myzr.com.cn/index.php?title=MY-IMX6-EK140P_Linux-4.1.15_%E6%B5%8B%E8%AF%95%E6%89%8B%E5%86%8C#][co...
Live replay: HARTING - How to quickly and cost-effectively install cables in electrical control cabinets : https://training.eeworld.com.cn/course/67824...
Machine vision is a comprehensive technology, including image processing, mechanical engineering technology, control, electric light source lighting, optical imaging, sensors, analog and digital video...
[i=s] This post was last edited by a media student on 2019-4-21 15:01 [/i] [align=center][align=center][size=4][b]【RT-Thread Reading Notes】 1. First Reading of RT-Thread RTOS [/b][/size][/align][/alig...
I have a question about an EXCEL curve fitting formula. I can't get the value of Y by substituting the values of X as 0, 150, and 300. The value of Y is incorrect. What is wrong? If any forum friends ...
Sensor and Testing Technology : https://training.eeworld.com.cn/course/5033Through this course, learners can understand the basic concepts of sensors and their basic characteristics (static and dynami...
According to Taiwanese media reports, TSMC plans to further increase its 8-inch mature process foundry quotation in the third quarter, while the 12-inch mature and advanced processes are still under ...[Details]
On October 19, the debut of Yitian 710, the first self-developed server chip by Pingtou Ge, a semiconductor company under Alibaba, became a "big event" at the 2021 Yunqi Conference. Who can compete w...[Details]
Strategy Analytics' latest research report, "2019 Smart Home Surveillance Camera Market Forecast and Analysis", points out that global consumers will spend nearly $8 billion on smart home cameras (in...[Details]
China Energy Storage Network News
: On June 3, the Xiamen Municipal Government and State Grid Fujian Electric Power Co., Ltd. signed the "Xiamen Ubiquitous Power Internet of Things Support Sm...[Details]
Japan's policy of restricting exports to South Korea has caused Korean companies to jump up and down. Yonhap News Agency further pointed out that the mask blank, a market monopolized by Japan, may be...[Details]
PART1.
Positional counting system A number system is also called a counting system. It refers to a method of expressing values using a set of fixed symbols and unified rules. The method of c...[Details]
When it comes to pure vision autonomous driving solutions, the first thing that comes to mind is Tesla. Indeed, as early as 2021, Tesla has already implemented a pure vision BEV detection solution,...[Details]
At present, modern residential meter reading systems mainly include IC cards and wireless remote meter reading, each with its own advantages. With the rapid development of microelectronics technolo...[Details]
With the advancement of science and technology, power quality has become the basis for the normal and good operation of various electrical equipment. A continuous research topic in the field of pow...[Details]
I believe many people have the experience of porting programs between different CPUs. In the process of porting, the porting of IO pins occupies most of the porting work. So, can a better method be us...[Details]
As the "common language" commonly used in the smart home industry, the HUAWEI HiLink platform realizes the interconnection and interoperability of smart devices and also provides greater development ...[Details]
1. Product overview of Fluke 707 loop calibrator: The ultra-fast handheld tool for loop calibration - the Fluke 707 Loop Calibrator (Loop Calibrator) is a high-performance solution for calibrating, r...[Details]
With the development of science and technology, the application fields of electronic measuring instruments are becoming more and more extensive. Over time, some faults will inevitably occur in the in...[Details]
Gyro motor is the main component of inertial device gyroscope, and gyroscope is the core component of inertial navigation system, which is widely used in ship navigation and various weapon systems....[Details]