E100EI
Series
1W, High Isolation
Ultra-Miniature SIP
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
•
1W Output Power
•
Ultra-Miniature SIP Case
•
3,000 VDC Isolation
•
14 Standard Models
•
>3.5 MHour MTBF
•
3.3V, 5V, 12V & 24V Inputs
•
LOWEST COST!!
Input
Parameter
Conditions
3.3 VDC Input
5 VDC Input
12 VDC Input
24 VDC Input
Min.
2.97
4.50
10.80
21.60
Typ.
3.3
5.0
12.0
24.0
Max.
3.63
5.50
13.20
26.40
0.3
Units
Input Voltage Range
VDC
Reverse Polarity Input Current
Input Filter
A
Internal Capacitor
Conditions
Min.
Typ.
±1.0
Max.
±3.0
±1.5
±1.2
150
±0.03
Units
%
%
Output
Parameter
Output Voltage Accuracy
Line Regulation, 3.3V Input Models
All Other Models
Load Regulation, See Note 1
Ripple & Noise (20 MHz)
Temperature Coefficient
Output Short Circuit, See Note 4
For Vin Change of 1%
See Model Selection Guide
See Note 3
100
±0.01
Momentary (1.0 Sec.)
Conditions
60 Seconds
500 VDC
100 kHz, 1V
Min.
3,000
1,000
Typ.
mV P - P
%/°C
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Max.
Units
VDC
M
pF
kHz
Units
°C
°C
%
60
100
Max.
+85
+125
95
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Conditions
Min.
Typ.
Ambient
-40
+25
-55
Free Air Convection
RH, Non-condensing
0.45 x 0.23 x 0.295 Inches (11.5 x 6.0 x 7.5 mm)
Non-Conductive Black Plastic (UL-94V0)
0.04 Oz (1.1g)
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Min.
Typ.
Max.
Units
3.5
MHours
Meets MIL-STD-202F, IEC68-2-6
Min.
-0.7
-0.7
-0.7
-0.7
Typ.
Max.
7.0
9.0
18.0
30.0
300
650
Units
Reliability Specifications
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T:
(781) 344-8226
F:
(781) 344-8481
E:
sales@micropowerdirect.com
W:
www.micropowerdirect.com
Parameter
MTBF
Shock & Vibration, See Note 5
Absolute Maximum Ratings
Parameter
Conditions
3.3 VDC Input
5 VDC Input
12 VDC Input
24 VDC Input
1.5 mm From Case For 10 Sec
All Models
Input Voltage Surge (1 Sec)
VDC
Lead Temperature
Internal Power Dissipation
°C
mW
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
Model Selection Guide
Model
Number
E101EI
E102EI
E103EI
E104EI
E111EI
E112EI
E113EI
E114EI
E121EI
E122EI
E123EI
E124EI
E151EI
E152EI
Input
Voltage
(VDC)
Current
(mA)
Voltage
Nominal
Range
Full-Load No-Load
(VDC)
5
4.5 - 5.5
290
50
5.0
5
4.5 - 5.5
263
50
9.0
5
4.5 - 5.5
256
50
12.0
5
4.5 - 5.5
256
50
15.0
12
10.8 - 13.2
117
21
5.0
12
10.8 - 13.2
113
21
9.0
12
10.8 - 13.2
107
21
12.0
12
10.8 - 13.2
105
21
15.0
24
21.6 - 26.4
58
17
5.0
24
21.6 - 26.4
54
17
9.0
24
21.6 - 26.4
54
17
12.0
24
21.6 - 26.4
53
17
15.0
3.3
2.97 - 3.63
432
76
3.3
3.3
2.97 - 3.63
415
76
5.0
Other input/output combinations are available
(i.e. 3.3 VDC). Contact the factory for details at:
sales@micropowerdirect.com
Notes:
1. Output load regulation is specified for a load change of 10% to 100%.
2. These units should not be operated with a load under 10% of full load. Operation at no-
load may cause damage to the unit.
3. These converters will operate without external components. However, when measuring out-
put ripple, it is recommended that
Input
Output
an external ceramic capacitor
Vin
Vout
be placed from the +Vout pin to
Capacitor
Capacitor
the -Vout pin. An input capacitor
3.3 VDC
4.7
µF
3.3 VDC 10.0
µF
will enhance stability over tem-
5 VDC
4.7
µF
5 VDC 10.0
µF
perature and input line variations.
Recommended capacitor values
12 VDC
2.2
µF
9 VDC
4.7
µF
are given in the table above. For
24 VDC
1.0
µF
12 VDC
2.2
µF
applications requiring very low
15 VDC
1.0
µF
output noise levels, a simple LC
filter should be effective.
4. After an output short circuit, the input power must be
recycled to operate the unit.
5. Given for frequency range of 5 to 500 Hz and PSD of 0.0248 g
2
/Hz.
Tested on X, Y & Z axis for 60 minutes.
6. It is recommended that a fuse be used on the input of a
power supply for protection. See the Model Selection
table above for the correct rating.
www.micropowerdirect.com
Output
Current
(mA, Max)
Current
(mA, Min)
Load Regulation
(% Typ)
(% Max)
Efficiency
(%, Typ)
Fuse Rating
Slow-Blow
(mA)
200.0
111.0
83.0
67.0
200.0
111.0
83.0
67.0
200.0
111.0
83.0
67.0
303.0
200.0
20.0
12.0
9.0
7.0
20.0
12.0
9.0
7.0
20.0
12.0
9.0
7.0
30.0
20.0
12.8
8.3
6.8
6.3
12.8
8.3
6.8
6.3
12.8
8.3
6.8
6.3
15.0
12.8
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
20.0
15.0
69
76
78
78
71
74
78
79
72
77
77
79
70
73
500
500
500
500
200
200
200
200
100
100
100
100
200
200
Derating Curve
Mechanical Dimensions
Pin Connections
Pin
1
2
3
4
Description
-Vin
+Vin
-Vout
+Vout
Notes:
•
All dimensions are typical in inches (mm)
•
Tolerance x.xx = ±0.01 (±0.25)
•
Pin 1 is marked by a “dot” or indentation on the side of the unit
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: sales@micropowerdirect.com