DC Power Cords MATING HARNESS
CategoryPower/power management    The power supply circuit   
File Size909KB,11 Pages
ManufacturerCosel
Download Datasheet Parametric View All

PBA1500F-5-F3 Online Shopping

Suppliers Part Number Price MOQ In stock  
PBA1500F-5-F3 - - View Buy Now

PBA1500F-5-F3 Overview

DC Power Cords MATING HARNESS

PBA1500F-5-F3 Parametric

Parameter NameAttribute value
package instruction,
Reach Compliance Codeunknown
Analog Integrated Circuits - Other TypesAC-DC REGULATED POWER SUPPLY MODULE
Base Number Matches1
AC-DC Power Supplies Enclosed Type
Ordering information
PBA/PBW
PBA/PBW
PBA300F
PB
1
2
A
3
300
4
F
5
-5
6
-O
R
Recommended EMI/EMC Filter
NAC-06-472
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The
EMI/EMC Filter is recommended
*to
connect with several devices.
1Series
name
2Single
output
3Output
wattage
4Universal
input
5Output
voltage
6Optional
*5
C :with Coating
G :Low leakage current
U :Operation stop voltage
is set at a lower value
F3 :Reverse air exhaust
type
F4 :Low speed fan
N1 :with DIN rail
Refer to instruction manual
7.1.
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
PBA300F-3R3
198
ACIN 100V 3.3V 60A
ACIN 200V
*
3
3.3V 60A
PBA300F-5
300
5V 60A
5V 60A
PBA300F-7R5
300
7.5V 40A
7.5V 40A
PBA300F-12
324
12V 27A
12V 27A
PBA300F-15
330
15V 22A
15V 22A
PBA300F-24
336
24V 14A
24V 14(16.5)A
PBA300F-36
324
36V 9A
36V 9A
PBA300F-48
336
48V 7A
48V 7A
SPECIFICATIONS
MODEL
VOLTAGE[V]
CURRENT[A]
FREQUENCY[Hz]
INPUT
ACIN 100V
ACIN 200V
ACIN 100V
POWER FACTOR
ACIN 200V
ACIN 100V
INRUSH CURRENT[A]
ACIN 200V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
ACIN 100V
CURRENT[A]
ACIN 200V
*
3
LINE REGULATION[mV]
LOAD REGULATION[mV]
0 to +50
C
*
1
RIPPLE[mVp-p]
-20 - 0
C
*
1
0 to +50
C
*
1
RIPPLE NOISE[mVp-p]
-20 - 0
C
*
1
0 to +50
C
TEMPERATURE REGULATION[mV]
-20 to +50
C
DRIFT[mV]
*
2
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION[V]
OPERATING INDICATION
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT
-
RC
INPUT-FG
OUTPUT
-
RC
-
AUX-FG
OUTPUT-RC
-
AUX
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS (At only AC input)
CONDUCTED NOISE
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
EFFICIENCY[%]
ACIN 100V
ACIN 200V
PBA300F-3R3 PBA300F-5
PBA300F-7R5 PBA300F-12 PBA300F-15
PBA300F-24
PBA300F-36
AC85 - 264 1
f
or DC120 - 350 (AC50 or DC70 Please refer to the instruction manual 7. option
*
4)
3typ
4.1typ
1.6typ
2typ
50/60 (47 - 63)
68typ
74typ
76typ
78typ
78typ
79typ
81typ
71typ
77typ
79typ
81typ
81typ
82typ
84typ
0.98typ (Io=100%)
0.95typ (Io=100%)
20/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More then 3 sec. to re-start)
40/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More then 3 sec. to re-start)
0.45/0.75max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1,DENAN)
3.3
5
7.5
12
15
24
36
60
60
40
27
22
14
9
60
60
40
27
22
14(16.5)
9
20max
20max
36max
48max
60max
96max
144max
40max
40max
60max
100max
120max
150max
150max
80max
80max
120max
120max
120max
120max
150max
140max
140max
160max
160max
160max
160max
160max
120max
120max
150max
150max
150max
150max
200max
160max
160max
180max
180max
180max
180max
240max
40max
50max
75max
120max
150max
240max
360max
60max
75max
120max
180max
180max
290max
440max
12max
20max
30max
48max
60max
96max
144max
300typ(ACIN 100/200V, Io=100%)
*
Start-up time is 500ms typ for less than 1minute of applying input again from turning off
20typ (ACIN 100/200V, Io=100%)
2.64 - 3.96
3.96 - 6.00
5.25 - 8.25
8.25 - 13.20
10.50 - 16.50 16.50 - 26.40 25.20 - 39.60
3.30 - 3.40
5.00 - 5.15
7.50 - 7.80
12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 36.00 - 37.44
Works over 105% of rated current or 101% of peak current and recovers automatically
4.3 - 6.3
6.5 - 8.0
9.0 - 11.6
14.4 - 18.6
18.0 - 23.3
28.8 - 37.2
43.2 - 54.0
LED (Green)
Provided
Provided
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50M
W
min (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50M
W
min (At Room Temperature)
-20 to +71
C
(Required Derating), 20 - 90%RH (Non condensing) 3,000m (10,000feet) max
-20 to +75
C
, 20 - 90%RH (Non condensing) 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN
Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
Complies with IEC61000-3-2
*
6
102
X
42
X
170mm [4.02
X
1.65
X
6.69 inches] (without terminal block and screw) (W
X
H
X
D) /1.0kg max
Forced cooling (internal fan)
*5
Please contact us about safety approvals for the model with option.
*6
Please contact us about class C.
*
A sound may occur from power supply at pulse loading.
PBA300F-48
79typ
82typ
OUTPUT
48
7
7
192max
300max
150max
400max
200max
500max
480max
600max
192max
the input voltage.
38.40 - 56.00
48.00 - 49.92
57.6 - 80.0
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
*1
Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN
:RM101).
*2
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
*3
() means peak current. Peak loading for 10s. And Duty 35% max, refer to Instruction manual
in detail.
*4
Derating is required.Consult us for details.
PBA/PBW-16
PBA/PBW-16
Hardware Design: Circuit Design of DSP TMS320C5509A
The C5509A DSP has very few general IO ports, which is not enough compared to the general ARM. Generally, CPLD is used to expand IO. If CPLD is not used, its IO can be fully utilized.First, it has 7 g...
Aguilera DSP and ARM Processors
VaST's latest modeling tool enables comprehensive software development before tapeout
VaST (VaST Systems Technology Corporation) and StarCore LLC recently announced that StarCore has joined the VaST Universe Partnership Initiative. VaST and StarCore users are using VaST's Virtual 1st S...
david PCB Design
What are the methods of remote communication? Which manufacturers have used specific products?
What are the methods of remote communication? Which specific products have been used?1. Ethernet communication method : Ethernet is the most common communication protocol standard used in existing loc...
蓝先生 Industrial Control Electronics
Regarding "Circuit Design Based on Operational Amplifiers and Analog Integrated Circuits", there is a concept of "Pole" that is not clear
[i=s]This post was last edited by sunboy25 on 2020-10-8 23:15[/i]I would like to ask, is the place where I drew the red circle in the picture above correct as described in the book? Why do I feel that...
sunboy25 Analog electronics
RISC-V IDE MRS usage notes (Part 3): Improving floating-point calculation efficiency
MRS has built-in CH32V30X series chips. This series of chips supports FPU (floating point unit). If you want to turn it on, you need to enable the corresponding extension, as shown in the figure below...
Moiiiiilter MCU
Pan it STM32H750 3 (lan8720 Ethernet test --iperf)
[font=宋体][size=4] When debugging lan8720 hardware, you need to check whether the ground pad is cold soldered, whether the internal voltage regulator 1.2V has output, and whether it has output 50M freq...
RCSN stm32/stm8

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号