Resistor spark suppression circuitb

Source: InternetPublisher:酷到被通缉 Keywords: BSP coil Updated: 2020/05/18

53.<strong>Resistor</strong>Spark elimination<strong>Circuit</strong>b.gif

DC relays, contactors and electromagnets are inductive loads. When the coil
is powered off, a high overvoltage will be generated at the contacts due to the existence of self-induced potential . It is added to the contact gap together with the power supply voltage to form spark discharge. This will not only accelerate contact
damage, but also generate a variable frequency signal that seriously interferes with radio communications. Therefore it must be eliminated.
    It must be pointed out that using a spark suppression circuit will delay the operation of relays and other devices.
    The circuit is shown in Figure 6-53. This circuit uses a resistor to provide a discharge circuit for the self-induced potential generated in the coil, so it is called
a resistor spark elimination circuit.
    In the figure, L and R are the inductance and resistance of the coil ,,. is the spark suppression resistor , and S is the moving and closing contact.
    For the circuit in Figure 6-53 (a), 2-3R can be selected; for the circuit in Figure 6-53 (b) , 3-5R can be selected.


EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

About Us Customer Service Contact Information Datasheet Sitemap LatestNews


Room 1530, 15th Floor, Building B, No.18 Zhongguancun Street, Haidian District, Beijing, Postal Code: 100190 China Telephone: 008610 8235 0740

Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号