When an asynchronous motor is used as a generator, if used improperly, the excitation capacitor may be easily damaged by overvoltage. For this purpose
, a capacitor overvoltage protection device can be installed. The circuit is shown in Figure 7-3.
    When the line voltage exceeds 400V, the overvoltage relay KAi operates, causing the capacitors Co and Cf to automatically exit to protect
the capacitors from damage.