Prevent misoperation of control circuits in both places

Source: InternetPublisher:3228 Keywords: control circuit buzzer motor Updated: 2020/06/14

33. Prevent misoperation<strong>Control<strong>circuit</strong></strong> between two places.gif

Using the circuit shown in Figure 4133 can prevent misoperation between the two places. When it is necessary to start,
the operator at location A presses the start button SB2. At this time, the buzzer
HA2 installed at location B can only sound. When the operator hears the bell, he presses the start button. After pressing the button SB3, the buzzer HA1 installed at ground A will buzz for a long time, and then the contactor KM will be energized to attract and self-energize. Its main contact will be closed, and the motor M will start. At the same time, the KM will switch off. The contacts are disconnected, causing HA1 and HA2 to lose power. When parking is required, the operator at location A can press SB1, and the operator at location B can press SB4.